External Quality Assurance Helps Improve Infrastructure for Testing Breast Biomarkers Across a Lower- and Middle-Income Country: Our Experience With Breast Biomarker Testing in the National Cancer Grid External Quality Assurance System in India.
Journal
Archives of pathology & laboratory medicine
ISSN: 1543-2165
Titre abrégé: Arch Pathol Lab Med
Pays: United States
ID NLM: 7607091
Informations de publication
Date de publication:
28 Dec 2023
28 Dec 2023
Historique:
accepted:
29
09
2023
medline:
28
12
2023
pubmed:
28
12
2023
entrez:
28
12
2023
Statut:
aheadofprint
Résumé
Biomarkers in breast cancer need strict monitoring given their role in patient management. To study the impact that regular participation in the National Cancer Grid (NCG) external quality assurance (EQA) system has on concordance rates for biomarkers in breast carcinoma. Tissue microarray (TMA) containing breast carcinomas was circulated to participating laboratories that performed immunohistochemistry for breast biomarkers. The returned TMAs were then assessed for test concordance. A total of 105 laboratories participated in the estrogen receptor (ER) and progesterone receptor (PR) EQA system cycles, and 99 centers participated in the human epidermal growth factor 2 (HER2) EQA system. In the ER EQA in the first cycle only 1 laboratory had a 100% concordance, which improved to 59 of 77 (76.6%) and 85 of 97 (85.9%) in the fourth and fifth cycles, respectively. In the PR EQA the 100% pass rate jumped from zero to 52 of 76 (68.4%) in the fourth cycle and 86 of 97 (88.6%) in the last cycle. For HER2 EQA, the 100% pass rates were seen in 7 of 23 laboratories (30.4%) in the first cycle, 49 of 78 laboratories (62.8%) in the fourth cycle, and 48 of 94 laboratories (51.1%) in fifth cycle of EQA. Centers who participated in the NCG EQA system for a longer period often changed testing methodology, with consequent improvement in their laboratory concordance rates. An increasing trend for the use of automated platforms and of the US Food and Drug Administration-approved antibody for HER2 testing was observed. Our experience demonstrates that laboratory performances improve with participation in an EQA system even in less perfect settings, and this drives the placement of more proficient practices across the country.
Identifiants
pubmed: 38153249
pii: 497902
doi: 10.5858/arpa.2023-0260-OA
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2023 College of American Pathologists.