Myelin bilayer mapping in the human brain in vivo.

HYFI high-performance gradient noise correlation quantitative mapping ultrashort-TE

Journal

Magnetic resonance in medicine
ISSN: 1522-2594
Titre abrégé: Magn Reson Med
Pays: United States
ID NLM: 8505245

Informations de publication

Date de publication:
03 Jan 2024
Historique:
revised: 27 11 2023
received: 14 09 2023
accepted: 15 12 2023
medline: 4 1 2024
pubmed: 4 1 2024
entrez: 3 1 2024
Statut: aheadofprint

Résumé

To quantitatively map the myelin lipid-protein bilayer in the live human brain. This goal was pursued by integrating a multi-TE acquisition approach targeting ultrashort T A multi-TE protocol (11 TEs of 20-780 μs) for in vivo brain imaging was developed in adherence with applicable safety regulations and practical scan time limits. Data acquired using this protocol produced accurate model fitting results, validating the suitability of the protocol for this purpose. Structured, grainy texture of myelin bilayer maps was observed and determined to be a manifestation of correlated image noise resulting from the employed acquisition strategy. Map quality was significantly improved by filtering to uniformize the k-space noise distribution and simultaneously extending the k-space support. The final myelin bilayer maps provided selective depiction of myelin, reconciling competitive resolution (1.4 mm) with adequate SNR and benign noise texture. Using the proposed technique, quantitative maps of the myelin bilayer can be obtained in vivo. These maps offer unique information content with potential applications in basic research, diagnosis, disease monitoring, and drug development.

Identifiants

pubmed: 38171541
doi: 10.1002/mrm.29998
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© 2024 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals LLC on behalf of International Society for Magnetic Resonance in Medicine.

Références

Rasband MN, Macklin WB. Myelin structure and biochemistry. In: Brady ST, Siegel GJ, Albers RW, Price DL, eds. Basic Neurochemistry. 8th ed/ ed. Elsevier; 2012:180-199.
World Health Organization. Neurological disorders: public health challenges. Available at: https://www.who.int/publications/i/item/9789241563369. 2006.
Reich DS, Lucchinetti CF, Calabresi PA. Multiple sclerosis. N Engl J Med. 2018;378:169-180.
MacKay A, Whittall K, Adler J, Li D, Paty D, Graeb D. In vivo visualization of myelin water in brain by magnetic resonance. Magn Reson Med. 1994;31:673-677.
MacKay AL, Laule C. Magnetic resonance of myelin water: an in vivo marker for myelin. Brain Plast. 2016;2:71-91.
Weiger M, Froidevaux R, Baadsvik EL, Brunner DO, Rösler MB, Pruessmann KP. Advances in MRI of the myelin bilayer. Neuroimage. 2020;217:116888.
Weiger M, Pruessmann KP. Short-T2 MRI: principles and recent advances. Prog Nucl Magn Reson Spectrosc. 2019;114-115:237-270.
Froidevaux R, Weiger M, Rösler MB, et al. High-resolution short-T2 MRI using a high-performance gradient. Magn Reson Med. 2020;84:1933-1946.
Baadsvik EL, Weiger M, Froidevaux R, Faigle W, Ineichen BV, Pruessmann KP. Mapping the myelin bilayer with short-T2 MRI: methods validation and reference data for healthy human brain. Magn Reson Med. 2023;89:665-677.
Baadsvik EL, Weiger M, Froidevaux R, Faigle W, Ineichen BV, Pruessmann KP. Quantitative magnetic resonance mapping of the myelin bilayer reflects pathology in multiple sclerosis brain tissue. Sci. Adv. 2023;9:eadi0611.
Balcom BJ, MacGregor RP, Beyea SD, Green DP, Armstrong RL, Bremner TW. Single-point ramped imaging with T1 enhancement (SPRITE). J Magn Reson Ser A. 1996;123:131-134.
Emid S, Creyghton JHN. High resolution NMR imaging in solids. Physica B+C. 1985;128:81-83.
Mastikhin IV, Balcom BJ. Centric SPRITE MRI of biomaterials with short T2*. eMagRes. 2012;1:783-788.
Wu YT, Dai GP, Ackerman JL, et al. Water- and fat-suppressed proton projection MRI (WASPI) of rat femur bone. Magn Reson Med. 2007;57:554-567.
Weiger M, Pruessmann KP. MRI with zero echo time. eMagRes. 2012;1:311-322.
Grodzki DM, Jakob PM, Heismann B. Ultrashort echo time imaging using pointwise encoding time reduction with radial acquisition (PETRA). Magn Reson Med. 2012;67:510-518.
Froidevaux R, Weiger M, Rosler MB, Brunner DO, Pruessmann KP. HYFI: hybrid filling of the dead-time gap for faster zero echo time imaging. NMR Biomed. 2021;34:e4493.
Weiger M, Overweg J, Rösler MB, et al. A high-performance gradient insert for rapid and short-T2 imaging at full duty cycle. Magn Reson Med. 2018;79:3256-3266.
Rösler MB, Weiger M, Brunner DO, Schmid T, Froidevaux R, Pruessmann KP. An RF birdcage coil designed for an insert gradient coil dedicated to short-T2 MRI. Proceedings of the 25th Annual Meeting of ISMRM. International Society for Magnetic Resonance in Medicine; 2017:2668.
Weiger M, Brunner DO, Dietrich BE, Muller CF, Pruessmann KP. ZTE imaging in humans. Magn Reson Med. 2013;70:328-332.
Schildknecht CM, Weiger M, Froidevaux R, Pruessmann KP. Rapid high power transmit-receive switching using a timed cascade of PIN diodes. Proceedings of the 30th Annual Meeting of ISMRM. International Society for Magnetic Resonance in Medicine; 2021:1411.
Rahmer J, Börnert P, Groen J, Bos C. Three-dimensional radial ultrashort echo-time imaging with T2 adapted sampling. Magn Reson Med. 2006;55:1075-1082.
Schieban K, Weiger M, Hennel F, Boss A, Pruessmann KP. ZTE imaging with enhanced flip angle using modulated excitation. Magn Reson Med. 2015;74:684-693.
Bloom M, Burnell EE, Valic MI, Weeks G. Nuclear magnetic resonance line shapes in lipid bi-layer model membranes. Chem Phys Lipids. 1975;14:107-112.
Wennerström H. Proton nuclear magnetic resonance lineshapes in lamellar liquid crystals. Chem Phys Lett. 1973;18:41-44.
The Wellcome Centre for Human Neuroimaging. Statistical Parametric Mapping (SPM) 12. UCL Queen Square Institute of Neurology. Available at: https://www.fil.ion.ucl.ac.uk/spm/software/spm12/. 2020.
Tesiram YA. Implementation equations for HSn RF pulses. J Magn Reson. 2010;204:333-339.
Hargreaves B. Rapid gradient-echo imaging. J Magn Reson Imaging. 2012;36:1300-1313.
Wansapura Janaka P, Holland Scott K, Dunn RS, Ball WS. NMR relaxation times in the human brain at 3.0 tesla. J Magn Reson Imaging. 1999;9:531-538.
Richter D. Neurochemistry. Springer; 1980:1-64.
Dubal L, Wiggli U. Tomochemistry of the brain. J Comput Assist Tomogr. 1977;1:300-307.
Robertson C. Theory and practical recommendations for autocorrelation-based image correlation spectroscopy. J Biomed Opt. 2012;17:080801.
Nagel AM, Laun FB, Weber M-A, Matthies C, Semmler W, Schad LR. Sodium MRI using a density-adapted 3D radial acquisition technique. Magn Reson Med. 2009;62:1565-1573.
Ma Y-J, Jerban S, Jang H, Chang D, Chang EY, Du J. Quantitative ultrashort echo time (UTE) magnetic resonance imaging of bone: an update. Front Endocrinol. 2020;11:567417.
Godenschweger F, Kägebein U, Stucht D, et al. Motion correction in MRI of the brain. Phys Med Biol. 2016;61:R32-R56.
Ljungberg E, Wood TC, Solana AB, Williams SCR, Barker GJ, Wiesinger F. Motion corrected silent ZTE neuroimaging. Magn Reson Med. 2022;88:195-210.
Wilhelm MJ, Ong HH, Wehrli SL, et al. Direct magnetic resonance detection of myelin and prospects for quantitative imaging of myelin density. Proc Natl Acad Sci. 2012;109:9605-9610.
Pampel A, Müller DK, Anwander A, Marschner H, Möller HE. Orientation dependence of magnetization transfer parameters in human white matter. Neuroimage. 2015;114:136-146.
Holmes JE, Bydder GM. MR imaging with ultrashort TE (UTE) pulse sequences: basic principles. Radiography. 2005;11:163-174.
Nayak KS, Pauly JM, Gold GE, Nishimura DG. Imaging ultra-short T2 species in the brain. Proceedings of the 8th Annual Meeting of ISMRM. International Society for Magnetic Resonance in Medicine; 2000:509.
Ercan E, Boernert P, Webb A, Ronen I. Whole-brain tissue-based assessment of the ultrashort T2 component using 3D UTE MRI relaxometry. Proceedings of the 20th Annual Meeting of ISMRM. International Society for Magnetic Resonance in Medicine; 2012:4279.
Du J, Ma G, Li S, et al. Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner. Neuroimage. 2014;87:32-41.
Sheth V, Shao H, Chen J, et al. Magnetic resonance imaging of myelin using ultrashort Echo time (UTE) pulse sequences: phantom, specimen, volunteer and multiple sclerosis patient studies. Neuroimage. 2016;136:37-44.
Fan SJ, Ma Y, Zhu Y, et al. Yet more evidence that myelin protons can be directly imaged with UTE sequences on a clinical 3T scanner: bicomponent T2* analysis of native and deuterated ovine brain specimens. Magn Reson Med. 2018;80:538-547.
Ma YJ, Searleman AC, Jang H, et al. Volumetric imaging of myelin in vivo using 3D inversion recovery-prepared ultrashort echo time cones magnetic resonance imaging. NMR Biomed. 2020;33:e4326.
Ma Y-J, Jang H, Wei Z, et al. Myelin imaging in human brain using a short repetition time adiabatic inversion recovery prepared ultrashort echo time (STAIR-UTE) MRI sequence in multiple sclerosis. Radiology. 2020;297:392-404.
Müller M, Egger N, Sommer S, et al. Direct imaging of white matter ultrashort T2* components at 7 Tesla. Magn Reson Imaging. 2022;86:107-117.
Shen X, Özen AC, Sunjar A, et al. Ultra-short T2 components imaging of the whole brain using 3D dual-echo UTE MRI with rosette k-space pattern. Magn Reson Med. 2023;89:508-521.
Seifert AC, Li C, Wilhelm MJ, Wehrli SL, Wehrli FW. Towards quantification of myelin by solid-state MRI of the lipid matrix protons. Neuroimage. 2017;163:358-367.
Seifert AC, Umphlett M, Hefti M, Fowkes M, Xu J. Formalin tissue fixation biases myelin-sensitive MRI. Magn Reson Med. 2019;82:1504-1517.
Jang H, Carl M, Ma Y, et al. Inversion recovery zero echo time (IR-ZTE) imaging for direct myelin detection in human brain: a feasibility study. Quant Imaging Med Surg. 2020;10:895-906.
Laule C, Vavasour IM, Kolind SH, et al. Magn Reson Imaging Myelin. Neurother. 2007;4:460-484.
Piredda GF, Hilbert T, Thiran JP, Kober T. Probing myelin content of the human brain with MRI: a review. Magn Reson Med. 2021;85:627-652.

Auteurs

Emily Louise Baadsvik (EL)

Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

Markus Weiger (M)

Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

Romain Froidevaux (R)

Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

Christoph Michael Schildknecht (CM)

Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

Benjamin Victor Ineichen (BV)

Department of Neuroradiology, Clinical Neuroscience Center, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
Center for Reproducible Science, University of Zurich, Zurich, Switzerland.

Klaas Paul Pruessmann (KP)

Institute for Biomedical Engineering, ETH Zurich and University of Zurich, Zurich, Switzerland.

Classifications MeSH