Uptake, discontinuation, and continuation rate of long-acting contraceptive methods (LARC) when offered at no cost in Campinas, Brazil.

Brazil continuation rate copper-IUD etonogestrel-implant levonorgestrel 52-mg IUD long-acting reversible contraceptive uptake

Journal

Contraception
ISSN: 1879-0518
Titre abrégé: Contraception
Pays: United States
ID NLM: 0234361

Informations de publication

Date de publication:
07 Jan 2024
Historique:
received: 11 10 2023
revised: 03 01 2024
accepted: 04 01 2024
medline: 10 1 2024
pubmed: 10 1 2024
entrez: 9 1 2024
Statut: aheadofprint

Résumé

To compare the uptake, reasons for discontinuation, continuation, and satisfaction of long-acting contraceptive methods (LARC) when offered at no cost in Campinas, Brazil. A prospective cohort study conducted at University of Campinas, Campinas, SP, Brazil, including women aged 18-43 years, who adopted one of three methods. Participants underwent telephone follow-up every three months for up to 24 months after insertion. Satisfaction was assessed at the end of two years of use through the Likert scale. We invited 1,222 women and among the 971 women who volunteered to participate in follow-up; 414 (42.6%) chose the levonorgestrel 52-mg intrauterine device (IUD), 358 (36.9%) the etonogestrel (ENG)-implant and 199 (20.5%) the TCu380A IUD. Discontinuation due to bothersome bleeding was higher among users of the ENG-implant (10/358; 2.4%) and the TCu380A IUD (32/199; 8.9%), and expulsion was higher for the TCu380A IUD (30/199; 15.1%). Women continued at 24 months were 340/414; 82.1%, 270/358; 75.4%, and 119/199; 59.8% among users of the levonorgestrel 52-mg IUD, ENG-implant, and TCu380A IUD, respectively. The users of the levonorgestrel 52-mg IUD (301/339; 88.8%), the ENG-implant (222/270; 82.2%), and the TCu380A IUD (105/119; 88.2%) were satisfied or very satisfied by 24 months of follow-up. The three LARC methods had great uptake, high continuation and discontinuation due to bothersome bleeding was higher among users of the ENG-implant and the TCu380A IUD, and expulsion was higher for the TCu380A IUD compared to the 52-mg levonorgestrel IUD. Most of the participants reported being very satisfied. When the LARC methods were offered at no cost in a Brazilian public clinic the uptake, satisfaction and continuation were high by 24-months after device placement and high level of satisfaction was reported by most of the participants.

Identifiants

pubmed: 38195047
pii: S0010-7824(24)00002-7
doi: 10.1016/j.contraception.2024.110363
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

110363

Informations de copyright

Copyright © 2024. Published by Elsevier Inc.

Auteurs

Montas Laporte (M)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil.

Ana C Marcelino (AC)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil.

Paula da Cunha Pereira (PDC)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil.

Ximena Espejo-Arce (X)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil.

Cassia T Juliato (CT)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil.

Luis Bahamondes (L)

Department of Obstetrics and Gynecology, University of Campinas Faculty of Medical Sciences, Campinas, SP, Brazil. Electronic address: bahamond@caism.unicamp.br.

Classifications MeSH