Mid-Term Results of an Italian Multicentric Experience with the Roadsaver

carotid artery stenosis carotid artery stenting dual-layer stent micromesh stroke

Journal

Healthcare (Basel, Switzerland)
ISSN: 2227-9032
Titre abrégé: Healthcare (Basel)
Pays: Switzerland
ID NLM: 101666525

Informations de publication

Date de publication:
04 Jan 2024
Historique:
received: 23 10 2023
revised: 13 12 2023
accepted: 03 01 2024
medline: 11 1 2024
pubmed: 11 1 2024
entrez: 11 1 2024
Statut: epublish

Résumé

Carotid artery stenting (CAS) using first-generation single-layer stents is widely accepted as a good alternative to standard carotid endarterectomy (CEA) but it is associated with worse outcomes in terms of both plaque prolapse and cerebral embolization. To evaluate the perioperative and midterm outcomes of CAS using the new-generation Roadsaver Herein, we present the results of an observational, retrospective, multicentric study on non-consecutive patients who underwent the CAS procedure between January 2017 and December 2022 at three Italian, high-volume vascular surgery centers. The inclusion criteria were the patients' eligibility for the CAS procedure in accordance with the current Italian guidelines, and the implantation of a Roadsaver stent. Both symptomatic and asymptomatic patients were included in the study. The patients requiring reintervention for carotid restenosis following CEA were also included. Perioperative data regarding procedural success was defined as the successful implantation of the device in the desired position, less than 30% residual stenosis, and the absence of intraoperative neurological complications. The primary outcome was any adverse cerebrovascular event such as stroke or transient ischemic attack (TIA) during the procedure and/or after discharge. The secondary outcomes were the need for further intervention, and all-cause death following procedure. Three-hundred-fifty-three (353) patients were included in our study; the mean age was 74.3 years. A total of 5.9% of the patients were symptomatic on their operated side, while 7.3% had contralateral carotid occlusion. A cerebral embolic protection device (CPD) was employed in all patients. A total of 13.3% of the patients were operated on for restenosis after CEA Technical success was achieved in 96.9% of the cases with an intraoperative report of six TIAs (1.7%) and six ipsilateral strokes (1.7%). The mean hospital stay was 1.8 days. The thirty-day follow up showed one TIA and one more stroke. At the mean 35-month follow-up time, the primary outcome was present in six patients (1.7%), where four TIAs (1.1%) and two strokes (0.5%) were reported. Restenosis occurred in five patients (1.4%). Death for any cause was reported in 11 patients (3.1%). As most recent, high-quality studies show, the CAS procedure with second-generation devices such as the Roadsaver stent is safe and effective in preventing carotid-related cerebrovascular events in both symptomatic and asymptomatic patients. The intraoperative and postoperative cerebrovascular complication rate in high volume centers is very low, ensuring confidence in its employment for the CAS procedure along with a CPD as a valid alternative to CEA.

Sections du résumé

BACKGROUND BACKGROUND
Carotid artery stenting (CAS) using first-generation single-layer stents is widely accepted as a good alternative to standard carotid endarterectomy (CEA) but it is associated with worse outcomes in terms of both plaque prolapse and cerebral embolization.
AIM OBJECTIVE
To evaluate the perioperative and midterm outcomes of CAS using the new-generation Roadsaver
METHODS METHODS
Herein, we present the results of an observational, retrospective, multicentric study on non-consecutive patients who underwent the CAS procedure between January 2017 and December 2022 at three Italian, high-volume vascular surgery centers. The inclusion criteria were the patients' eligibility for the CAS procedure in accordance with the current Italian guidelines, and the implantation of a Roadsaver stent. Both symptomatic and asymptomatic patients were included in the study. The patients requiring reintervention for carotid restenosis following CEA were also included. Perioperative data regarding procedural success was defined as the successful implantation of the device in the desired position, less than 30% residual stenosis, and the absence of intraoperative neurological complications. The primary outcome was any adverse cerebrovascular event such as stroke or transient ischemic attack (TIA) during the procedure and/or after discharge. The secondary outcomes were the need for further intervention, and all-cause death following procedure.
RESULTS RESULTS
Three-hundred-fifty-three (353) patients were included in our study; the mean age was 74.3 years. A total of 5.9% of the patients were symptomatic on their operated side, while 7.3% had contralateral carotid occlusion. A cerebral embolic protection device (CPD) was employed in all patients. A total of 13.3% of the patients were operated on for restenosis after CEA Technical success was achieved in 96.9% of the cases with an intraoperative report of six TIAs (1.7%) and six ipsilateral strokes (1.7%). The mean hospital stay was 1.8 days. The thirty-day follow up showed one TIA and one more stroke. At the mean 35-month follow-up time, the primary outcome was present in six patients (1.7%), where four TIAs (1.1%) and two strokes (0.5%) were reported. Restenosis occurred in five patients (1.4%). Death for any cause was reported in 11 patients (3.1%).
CONCLUSIONS CONCLUSIONS
As most recent, high-quality studies show, the CAS procedure with second-generation devices such as the Roadsaver stent is safe and effective in preventing carotid-related cerebrovascular events in both symptomatic and asymptomatic patients. The intraoperative and postoperative cerebrovascular complication rate in high volume centers is very low, ensuring confidence in its employment for the CAS procedure along with a CPD as a valid alternative to CEA.

Identifiants

pubmed: 38201025
pii: healthcare12010120
doi: 10.3390/healthcare12010120
pii:
doi:

Types de publication

Journal Article

Langues

eng

Auteurs

Olga Silvestri (O)

Department of Public Health, Vascular Surgery Unit, University Federico II of Naples, 80131 Naples, Italy.

Giulio Accarino (G)

Department of Public Health, Vascular Surgery Unit, University Federico II of Naples, 80131 Naples, Italy.
Department of Medicine, Surgery and Dentistry, University of Salerno, 84084 Fisciano, Italy.

Davide Turchino (D)

Department of Public Health, Vascular Surgery Unit, University Federico II of Naples, 80131 Naples, Italy.

Francesco Squizzato (F)

Department of Cardiac, Thoracic and Vascular Sciences and Public Health, School of Medicine, Padua University Hospital, 35100 Padua, Italy.

Michele Piazza (M)

Department of Cardiac, Thoracic and Vascular Sciences and Public Health, School of Medicine, Padua University Hospital, 35100 Padua, Italy.

Martina Bastianon (M)

Vascular and Endovascular Surgery, IRCCS Ospedale Policlinico San Martino, University of Genova, 16100 Genova, Italy.

Sara Di Gregorio (S)

Vascular and Endovascular Surgery, IRCCS Ospedale Policlinico San Martino, University of Genova, 16100 Genova, Italy.

Giovanni Pratesi (G)

Vascular and Endovascular Surgery, IRCCS Ospedale Policlinico San Martino, University of Genova, 16100 Genova, Italy.

Michele Antonello (M)

Department of Cardiac, Thoracic and Vascular Sciences and Public Health, School of Medicine, Padua University Hospital, 35100 Padua, Italy.

Davide Costa (D)

Interuniversity Center of Phlebolymphology (CIFL), International Research and Educational Program in Clinical and Experimental Biotechnology, University Magna Graecia of Catanzaro, 88100 Catanzaro, Italy.

Raffaele Serra (R)

Interuniversity Center of Phlebolymphology (CIFL), International Research and Educational Program in Clinical and Experimental Biotechnology, University Magna Graecia of Catanzaro, 88100 Catanzaro, Italy.

Umberto Marcello Bracale (UM)

Department of Public Health, Vascular Surgery Unit, University Federico II of Naples, 80131 Naples, Italy.

Classifications MeSH