In Vitro Comparison of Differences in Setting Time of Premixed Calcium Silicate-Based Mineral Trioxide Aggregate According to Moisture Content of Gypsum.

gypsum mold micro-CT moisture premixed calcium silicate MTA setting time

Journal

Materials (Basel, Switzerland)
ISSN: 1996-1944
Titre abrégé: Materials (Basel)
Pays: Switzerland
ID NLM: 101555929

Informations de publication

Date de publication:
21 Dec 2023
Historique:
received: 16 11 2023
revised: 18 12 2023
accepted: 18 12 2023
medline: 11 1 2024
pubmed: 11 1 2024
entrez: 11 1 2024
Statut: epublish

Résumé

Recently, a paste-type premixed calcium silicate-based mineral trioxide aggregate (MTA) product that quickly solidifies through a pozzolanic reaction was introduced to replace existing MTA, which has the disadvantage of a long setting time. In this study, we evaluated the effect of moisture content in the root canal on the setting time of premixed calcium silicate-based MTA in a simulated root canal environment using Endoseal MTA and Well-Root ST, among commercially available products. The setting time was measured according to ISO 6876/2012. A mold made using grades 2, 3, and 4 dental gypsum according to the classification of ISO 6873/2013 was used to reproduce the difference in moisture environment. Differences in moisture content were measured using micro-computed X-ray tomography (micro-CT). The micro-CT results showed that the moisture content was the highest and lowest in the grade 2 and 4 gypsum molds, respectively. Moreover, the setting time indicated by the manufacturer was the shortest for the grade 2 gypsum mold. Hence, the differences in moisture content significantly affect the setting time of MTA. This result can help set future experimental conditions and develop premixed calcium silicate-based MTA products.

Identifiants

pubmed: 38203889
pii: ma17010035
doi: 10.3390/ma17010035
pii:
doi:

Types de publication

Journal Article

Langues

eng

Subventions

Organisme : Ministry of Food and Drug Safety
ID : 23201MFDS170

Auteurs

Hyun-Jin Kim (HJ)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Jun-Seok Lee (JS)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Dong-Hoon Gwak (DH)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Yong-Seok Ko (YS)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Chun-Il Lim (CI)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Seung-Youl Lee (SY)

Medical Device Research Division, National Institute of Food and Drug Safety Evaluation, Cheongju 28159, Republic of Korea.

Classifications MeSH