Anesthesia Patient Monitoring 2050.
Journal
Anesthesia and analgesia
ISSN: 1526-7598
Titre abrégé: Anesth Analg
Pays: United States
ID NLM: 1310650
Informations de publication
Date de publication:
01 Feb 2024
01 Feb 2024
Historique:
medline:
13
1
2024
pubmed:
13
1
2024
entrez:
12
1
2024
Statut:
ppublish
Résumé
The monitoring of vital signs in patients undergoing anesthesia began with the very first case of anesthesia and has evolved alongside the development of anesthesiology ever since. Patient monitoring started out as a manually performed, intermittent, and qualitative assessment of the patient's general well-being in the operating room. In its evolution, patient monitoring development has responded to the clinical need, for example, when critical incident studies in the 1980s found that many anesthesia adverse events could be prevented by improved monitoring, especially respiratory monitoring. It also facilitated and perhaps even enabled increasingly complex surgeries in increasingly higher-risk patients. For example, it would be very challenging to perform and provide anesthesia care during some of the very complex cardiovascular surgeries that are almost routine today without being able to simultaneously and reliably monitor multiple pressures in a variety of places in the circulatory system. Of course, anesthesia patient monitoring itself is enabled by technological developments in the world outside of the operating room. Throughout its history, anesthesia patient monitoring has taken advantage of advancements in material science (when nonthrombogenic polymers allowed the design of intravascular catheters, for example), in electronics and transducers, in computers, in displays, in information technology, and so forth. Slower product life cycles in medical devices mean that by carefully observing technologies such as consumer electronics, including user interfaces, it is possible to peek ahead and estimate with confidence the foundational technologies that will be used by patient monitors in the near future. Just as the discipline of anesthesiology has, the patient monitoring that accompanies it has come a long way from its beginnings in the mid-19th century. Extrapolating from careful observations of the prevailing trends that have shaped anesthesia patient monitoring historically, patient monitoring in the future will use noncontact technologies, will predict the trajectory of a patient's vital signs, will add regional vital signs to the current systemic ones, and will facilitate directed and supervised anesthesia care over the broader scope that anesthesia will be responsible for.
Identifiants
pubmed: 38215707
doi: 10.1213/ANE.0000000000006660
pii: 00000539-202402000-00007
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
273-283Informations de copyright
Copyright © 2023 International Anesthesia Research Society.
Déclaration de conflit d'intérêts
Conflicts of Interest: See Disclosures at the end of the article.
Références
Desai SP, Desai MS, Maddi R, Battit GE. A tale of two paintings: depictions of the first public demonstration of ether anesthesia. Anesthesiology. 2007;106:1046–1050.
Pierce EC Jr. Does monitoring have an effect on patient safety? Monitoring instruments have significantly reduced anesthetic mishaps. J Clin Monit. 1988;4:111–114.
Snow J. A lecture on the inhalation of vapour of ether in surgical operations. Lancet. 1847;49:551–554.
Duncum BM. The Jubilee of Anaesthesia. The Development of Inhalation Anaesthesia With Special Reference to the Years 1846–1900. Oxford University Press (for The Wellcome Historical Medical Museum); 1947:524–551.
Clover JT. On an apparatus for administering nitrous oxide gas and ether, singly or combined. Br Med J. 1876;2:74–75.
Ludwig C. Beiträge zur Kenntniss des Einflusses der Respirationsbewegungen auf den Blutlauf in Aortensystemen. Archiv für Anatomie Physiologie und Wissenschaftliche Medicin. 1847;4:242–302.
Booth J. A short history of blood pressure measurement. Proc R Soc Med. 1977;70:793–799.
Cushing H. On routine determinations of arterial tension in operating room and clinic. Boston Med Surg J. 1903;148:250–256.
Korotkoff NC. On the subject of methods of determining blood pressure. Bull Imperial Mil Med Acad. 1905;11:365–367.
Silas JH, Barker AT, Ramsay LE. Clinical evaluation of Dinamap 845 automated blood pressure recorder. Br Heart J. 1980;43:202–205.
Fink BR. Times of the signs. The origins of charting. In: Fink BR, Morris LE, Stephen CR, eds. The History of Anesthesia 3rd International Symposium. Wood Library-Museum of Anesthesiology, 1992:165–168.
Cushing HI. On the avoidance of shock in major amputations by cocainization of large nerve-trunks preliminary to their division. With observations on blood-pressure changes in surgical cases. Ann Surg. 1902;36:321–345.
Kirk R. On auscultation of the heart during chloroform narcosis. Br Med J. 1896;2:1704–1706.
Teter CK. Thirteen thousand administrations of nitrous oxide with oxygen as an anesthetic. J Am Med Assoc. 1909;LIII:448.
Einthoven W. Ueber die Form des menschlichen Electrocardiogramms. Pflüger, Archiv für die Gesammte Physiologie des Menschen und der Thiere. 1895;60:101–123.
Lennox WG. An electrocardiographic study of fifty patients during operation. Arch Intern Med. 1922;30:57.
Swan HJ, Ganz W, Forrester J, Marcus H, Diamond G, Chonette D. Catheterization of the heart in man with use of a flow-directed balloon-tipped catheter. N Engl J Med. 1970;283:447–451.
Beecher HK, Todd DP. A study of the deaths associated with anesthesia and surgery: based on a study of 599, 548 anesthesias in ten institutions 1948-1952, inclusive. Ann Surg. 1954;140:2–35.
Christie TH, Churchill-Davidson HC. The St. Thomas’s Hospital nerve stimulator in the diagnosis of prolonged apnoea. Lancet. 1958;1:776.
Savarese JJ. Monitoring of neuromuscular function: past, present, and future. ASA Newsletter. 2002;66:20–21.
Severinghaus JW, Bradley AF. Electrodes for blood pO2 and pCO2 determination. J Appl Physiol. 1958;13:515–520.
Severinghaus JW, Honda Y. History of blood gas analysis. VII. Pulse oximetry. J Clin Monit. 1987;3:135–138.
Penaz J, ed. Photoelectric measurement of blood pressure, volume and flow in the finger. 10th International Conf Med Biol Engg; 1973; Dresden, Germany.
Morris RH. Operating room temperature and the anesthetized, paralyzed patient. Arch Surg. 1971;102:95–97.
Arkilic CF, Akca O, Taguchi A, Sessler DI, Kurz A. Temperature monitoring and management during neuraxial anesthesia: an observational study. Anesth Analg. 2000;91:662–666.
Sessler DI. Perioperative temperature monitoring. Anesthesiology. 2021;134:111–118.
Cooper JB, Newbower RS, Long CD, McPeek B. Preventable anesthesia mishaps: a study of human factors. Anesthesiology. 1978;49:399–406.
Cooper JB, Newbower RS, Kitz RJ. An analysis of major errors and equipment failures in anesthesia management: considerations for prevention and detection. Anesthesiology. 1984;60:34–42.
Aoyagi T, Kishi M, Yamaguchi K, Watanabe S. Improvement of the earpiece oximeter. 13th Annual Meeting of the Japanese Society of Medical Electronics and Biological Engineering; April 26–27, 1974; Osaka, Japan; 1974:90–91.
Nitzan M, Romem A, Koppel R. Pulse oximetry: fundamentals and technology update. Med Devices (Auckl). 2014;7:231–239.
Tyndall J. On radiation: The “Rede” Lecture Delivered in the Senate-House Before The University of Cambridge on Tuesday, May 16, 1865. Longman, Green, Longman, Roberts & Green; 1865:62.
Tyndall J. Fragments of Science for Unscientific People: A Series of Detached Essays, Lectures, and Reviews. D. Appleton and Company; 1871:422.
Luft ΚF, Schaefer W, Wiegleb G. 50 Jahre NDIR-Gasanalyse/50 years NDIR gas analysis. Teme. 1993;60:363–371.
Jaffe MB. Infrared measurement of carbon dioxide in the human breath: “breathe-through” devices from Tyndall to the present day. Anesth Analg. 2008;107:890–904.
Epstein BS. ASA adopts standards for the practice of anesthesiology. Arch Surg. 1987;122:1215–1216.
Mylrea KC, Orr JA, Westenskow DR. Integration of monitoring for intelligent alarms in anesthesia: neural networks--can they help? J Clin Monit. 1993;9:31–37.
Michels P, Gravenstein D, Westenskow DR. An integrated graphic data display improves detection and identification of critical events during anesthesia. J Clin Monit. 1997;13:249–259.
Blike GT, Surgenor SD, Whalen K. A graphical object display improves anesthesiologists’ performance on a simulated diagnostic task. J Clin Monit Comput. 1999;15:37–44.
Wallace AW, Salahieh A, Lawrence A, Spector K, Owens C, Alonso D. Endotracheal cardiac output monitor. Anesthesiology. 2000;92:178–189.
Ouzounian JG, Masaki DI, Abboud TK, Greenspoon JS. Systemic vascular resistance index determined by thoracic electrical bioimpedance predicts the risk for maternal hypotension during regional anesthesia for cesarean delivery. Am J Obstet Gynecol. 1996;174:1019–1025.
Haryadi DG, Orr JA, Kuck K, McJames S, Westenskow DR. Partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput. 2000;16:361–374.
Kuck K, Orr JA, Brewer LM. Noninvasive cardiac output performance improved after sufficient stabilization time following decrease of ventilation. Anesthesiology. 2003;99:1460.
Sigl JC, Chamoun NG. An introduction to bispectral analysis for the electroencephalogram. J Clin Monit. 1994;10:392–404.
Gao WW, He YH, Liu L, Yuan Q, Wang YF, Zhao B. BIS monitoring on intraoperative awareness: a meta-analysis. Curr Med Sci. 2018;38:349–353.
Lewis SR, Pritchard MW, Fawcett LJ, Punjasawadwong Y. Bispectral index for improving intraoperative awareness and early postoperative recovery in adults. Cochrane Database Syst Rev. 2019;9:CD003843.
Jobsis FF. Noninvasive, infrared monitoring of cerebral and myocardial oxygen sufficiency and circulatory parameters. Science. 1977;198:1264–1267.
Ferrari M, Quaresima V. Near infrared brain and muscle oximetry: from the discovery to current applications. J Near Infrared Spectrosc. 2012;20:1–14.
Macknet MR, Allard M, Applegate RL II, Rook J. The accuracy of noninvasive and continuous total hemoglobin measurement by pulse CO-Oximetry in human subjects undergoing hemodilution. Anesth Analg. 2010;111:1424–1426.
Eichhorn JH, Cooper JB, Cullen DJ, Maier WR, Philip JH, Seeman RG. Standards for patient monitoring during anesthesia at Harvard Medical School. JAMA. 1986;256:1017–1020.
Pandya AN, Majid SZ, Desai MS. The origins, evolution, and spread of anesthesia monitoring standards: from Boston to across the world. Anesth Analg. 2021;132:890–898.
American Society of Anesthesiologists. Standards for basic anesthetic monitoring. Standards and Practice Parameters Committee. 2010. Accessed May 29, 2023. Available at: https://www.asahq.org/standards-and-guidelines/standards-for-basic-anesthetic-monitoring.
Klein AA, Meek T, Allcock E, et al. Recommendations for standards of monitoring during anaesthesia and recovery 2021: guideline from the Association of Anaesthetists. Anaesthesia. 2021;76:1212–1223.
European Board of Anaesthesiology. Recommendations for minimal monitoring during Anaesthesia and Recovery. 2012. Accessed May 29, 2023. Available at: http://www.eba-uems.eu/resources/PDFS/safety-guidelines/EBA-Minimal-monitor.pdf.
Australian and New Zealand College of Anaesthetists and Faculty of Pain Medicine. Guideline on monitoring during anaesthesia. 2017. Accessed May 29, 2023. Available at: https://www.anzca.edu.au/getattachment/0c2d9717-fa82-4507-a3d6-3533d8fa844d/PS18-Guideline-on-monitoring-during-anaesthesia.
International Federation of Nurse Anaesthetists. Code of Ethics, Standards of Practice, Monitoring, and Education. 2016. Accessed May 29, 2023. Available at: https://ifna.site/app/uploads/2015/08/IFNA-STANDARDS-2016.pdf.
Gelb AW, Morriss WW, Johnson W, et al.; International Standards for a Safe Practice of Anesthesia Workgroup. World Health Organization-World Federation of Societies of Anaesthesiologists (WHO-WFSA) International Standards for a Safe Practice of Anesthesia. Anesth Analg. 2018;126:2047–2055.
International Standards Organization (ISO). Medical Electrical Equipment - Part 2-13: Particular Requirements For Basic Safety And Essential Performance Of An Anaesthetic Workstation (ISO 80601-2-13). Geneva, Switzerland; 2011.
Hendrickx JFA, Feldman JM, Schüler HU. Anesthetic monitoring recommendations during general anesthesia: How consistent are they across the globe? In: Preckel B, Staender S, Arnal D, . Ten years of the Helsinki declaration on patient safety in anaesthesiology: an expert opinion on perioperative safety aspects. Eur J Anaesthesiol. 2020;37:521–610.
Apple Inc. De Novo Classification Request for ECG App (2017). Accessed March 2023. Available at: https://wwwaccessdatafdagov/cdrh_docs/reviews/DEN180044pdf. DEN180044.
Thomson EA, Nuss K, Comstock A, et al. Heart rate measures from the Apple Watch, Fitbit Charge HR 2, and electrocardiogram across different exercise intensities. J Sports Sci. 2019;37:1411–1419.
Paech C, Kobel M, Michaelis A, et al. Accuracy of the Apple Watch single-lead ECG recordings in pre-term neonates. Cardiol Young. 2022;32:1633–1637.
Seshadri DR, Bittel B, Browsky D, et al. Accuracy of Apple Watch for detection of atrial fibrillation. Circulation. 2020;141:702–703.
Strik M, Caillol T, Ramirez FD, et al. Validating QT-interval measurement using the Apple Watch ECG to enable remote monitoring during the COVID-19 pandemic. Circulation. 2020;142:416–418.
World Health Organization. Ageing and Health. 2022. Accessed May 29, 2023. Available at: https://www.who.int/news-room/fact-sheets/detail/ageing-and-health.
Asiri A, AlBishi S, AlMadani W, ElMetwally A, Househ M. The use of telemedicine in surgical care: a systematic review. Acta Inform Med. 2018;26:201–206.
Bray JO, Sutton TL, Akhter MS, Iqbal E, Orenstein SB, Nikolian VC. Telemedicine-based new patient consultations for hernia repair and advanced abdominal wall reconstruction. Hernia. 2022;26:1687–1694.
Jacob AK, Belch LM, Pai SL. Telehealth in anesthesia. Adv Anesth. 2021;39:259–268.
Pipek LZ, Nascimento RFV, Acencio MMP, Teixeira LR. Comparison of SpO(2) and heart rate values on Apple Watch and conventional commercial oximeters devices in patients with lung disease. Sci Rep. 2021;11:18901.
Bai Y, Hibbing P, Mantis C, Welk GJ. Comparative evaluation of heart rate-based monitors: Apple Watch vs Fitbit Charge HR. J Sports Sci. 2018;36:1734–1741.
Dorr M, Nohturfft V, Brasier N, et al. The WATCH AF trial: SmartWATCHes for detection of atrial fibrillation. JACC Clin Electrophysiol. 2019;5:199–208.
Hickey BA, Chalmers T, Newton P, et al. Smart devices and wearable technologies to detect and monitor mental health conditions and stress: a systematic review. Sensors (Basel). 2021;21:3461.
Tasoglu S. Toilet-based continuous health monitoring using urine. Nat Rev Urol. 2022;19:219–230.
Park SM, Won DD, Lee BJ, et al. A mountable toilet system for personalized health monitoring via the analysis of excreta. Nat Biomed Eng. 2020;4:624–635.
Addison AP, Addison PS, Smit P, Jacquel D, Borg UR. Noncontact respiratory monitoring using depth sensing cameras: a review of current literature. Sensors (Basel). 2021;21:1135.
Abbas AK, Heimann K, Jergus K, Orlikowsky T, Leonhardt S. Neonatal non-contact respiratory monitoring based on real-time infrared thermography. Biomed Eng Online. 2011;10:93.
Aarts LA, Jeanne V, Cleary JP, et al. Non-contact heart rate monitoring utilizing camera photoplethysmography in the neonatal intensive care unit - a pilot study. Early Hum Dev. 2013;89:943–948.
Al-Khalidi FQ, Saatchi R, Burke D, Elphick H, Tan S. Respiration rate monitoring methods: a review. Pediatr Pulmonol. 2011;46:523–529.
L’Her E, Nazir S, Pateau V, Visvikis D. Accuracy of noncontact surface imaging for tidal volume and respiratory rate measurements in the ICU. J Clin Monit Comput. 2022;36:775–783.
Jorge J, Villarroel M, Tomlinson H, et al. Non-contact physiological monitoring of post-operative patients in the intensive care unit. NPJ Digit Med. 2022;5:4.
Moonla C, Goud KY, Teymourian H, et al. An integrated microcatheter-based dual-analyte sensor system for simultaneous, real-time measurement of propofol and fentanyl. Talanta. 2020;218:121205.
Evans RG, Smith JA, Wright C, Gardiner BS, Smith DW, Cochrane AD. Urinary oxygen tension: a clinical window on the health of the renal medulla? Am J Physiol Regul Integr Comp Physiol. 2014;306:R45–R50.
Silverton NA, Lofgren LR, Hall IE, et al. Noninvasive urine oxygen monitoring and the risk of acute kidney injury in cardiac surgery. Anesthesiology. 2021;135:406–418.
DeSear KE, Thompson-Leduc P, Van Schooneveld TC, et al. Decreased antibiotic exposure using a procalcitonin protocol for respiratory infections and sepsis in US community hospitals (ProCommunity). Curr Med Res Opin. 2021;37:727–733.
Koleck TA, Dreisbach C, Bourne PE, Bakken S. Natural language processing of symptoms documented in free-text narratives of electronic health records: a systematic review. J Am Med Inform Assoc. 2019;26:364–379.
West N, van Heusden K, Gorges M, et al. Design and evaluation of a closed-loop anesthesia system with robust control and safety system. Anesth Analg. 2018;127:883–894.
Szmuk P, Steiner JW, Olomu PN, Ploski RP, Sessler DI, Ezri T. Oxygen reserve index: a novel noninvasive measure of oxygen reserve--a pilot study. Anesthesiology. 2016;124:779–784.
Hatib F, Jian Z, Buddi S, et al. Machine-learning algorithm to predict hypotension based on high-fidelity arterial pressure waveform analysis. Anesthesiology. 2018;129:663–674.