Mitigation strategies to reduce particulate matter concentrations in civil engineering laboratories.
Air pollution
Civil engineering
Hazard control
Indoor air quality
Laboratory
Particulate matter
Respirable dust
Journal
Environmental science and pollution research international
ISSN: 1614-7499
Titre abrégé: Environ Sci Pollut Res Int
Pays: Germany
ID NLM: 9441769
Informations de publication
Date de publication:
17 Jan 2024
17 Jan 2024
Historique:
received:
02
03
2023
accepted:
04
01
2024
medline:
17
1
2024
pubmed:
17
1
2024
entrez:
17
1
2024
Statut:
aheadofprint
Résumé
In the departments of civil engineering, many experiments are conducted in laboratories for educational and research purposes. Varying degrees of respirable dust are generated as the outcome of these experiments, which could cause harm to instructors' and students' health. This study is devised to highlight the importance of indoor air quality in university laboratories. As part of the research, four different particulate matter (PM) sizes (PM
Identifiants
pubmed: 38231331
doi: 10.1007/s11356-024-31926-w
pii: 10.1007/s11356-024-31926-w
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024. The Author(s).
Références
ACGIH (The American Conference of Governmental Industrial Hygienists) (1998) Industrial ventilation: a manual of recommended practice. 23rd ed., Cincinnati, Ohio, USA
Ahmed S, Arocho I (2019) Emission of particulate matters during construction: a comparative study on a cross laminated timber (CLT) and a steel building construction project. J Build Eng 22:281–294. https://doi.org/10.1016/j.jobe.2018.12.015
doi: 10.1016/j.jobe.2018.12.015
Anderson J, Thundiyil J, Stolbach A (2012) Clearing the air: a review of the effects of particulate matter air pollution on human health. J Med Toxicol 8:166–175. https://doi.org/10.1007/s13181-011-0203-1
doi: 10.1007/s13181-011-0203-1
ASHRAE (American Society of Heating, Refrigerating and Air-Conditioning Engineers) (2013) Ventilation for acceptable indoor air quality. Atlanta, GA., Inc., Standard 62.1–2013
Azarmi F, Kumar P, Mulheron M (2014) The exposure to coarse, fine and ultrafine particle emissions from concrete mixing, drilling and cutting activities. J Hazard Mat 279:268–279. https://doi.org/10.1016/j.jhazmat.2014.07.003
doi: 10.1016/j.jhazmat.2014.07.003
Bai M, Liu Y, Qi M, Roy N, Shu CM, Khan F, Zhao D (2022) Current status, challenges, and future directions of university laboratory safety in China. J Loss Prev Process Ind 74:104671
doi: 10.1016/j.jlp.2021.104671
Chang Y, Hu W, Su K et al (2014) PM10 Emissions reduction from exposed areas using grass-planted covering: field study of a construction site. Environ Eng 140(12):06014006. https://doi.org/10.1061/(ASCE)EE.1943-7870.0000867
doi: 10.1061/(ASCE)EE.1943-7870.0000867
Chenari B, Carrilho JD, Silva MG (2016) Towards sustainable, energy-efficient and healthy ventilation strategies in buildings: a review. Renew Sust Energ Rev 59:1426–1447
doi: 10.1016/j.rser.2016.01.074
Cheriyan D, Choi JH (2020) Estimation of particulate matter exposure to construction workers using low-cost dust sensors. Sustain Cities Soc 59(2):102197. https://doi.org/10.1016/j.scs.2020.102197
EPA (Environmental Protection Authority) (2012) Ambient air quality - standards and laws. https://www.epa.gov/pm-pollution/2012-national-ambient-air-quality-standards-naaqs-particulate-matter-pm . Accessed date: 26.12.2022
General Directorate of Meteorology (2019) Climate Conditions of Izmir City. http://izmir.mgm.gov.tr/FILES/iklim/izmir_iklim.pdf . Accessed date: 26.12.2022
Grigg J (2009) Particulate matter exposure in children. Proc Am Thorac Soc 6:564–569
doi: 10.1513/pats.200905-026RM
Guo P, Tian W, Li H (2022) Dynamic health risk assessment model for construction dust hazards in the reuse of industrial buildings. Build Environ 210:108736
doi: 10.1016/j.buildenv.2021.108736
Haynes RC (2006) Air pollution: the plaque of the matter. Environ Health Perspect 114(4):218. https://doi.org/10.1289/ehp.114-a218a
doi: 10.1289/ehp.114-a218a
Haynes R, Savage A (2007) Assessment of the health impacts of particulates from the redevelopment of Kings Cross. Environ Mon Assess 130(1–3):47–56
doi: 10.1007/s10661-006-9449-5
Holton I, Glass I, Price A (2008) Developing a successful sector sustainability strategy: six lessons from the UK construction products industry. Corp Soc Responsib Environ Manag 15(1):29–42
doi: 10.1002/csr.135
HSE (Health and Safety Executive) (1998) The selection use and maintenance of respiratory protective equipment - a practical guide. HSG 53 (4th ed.) UK
Hu Y, Wu M, Li Y, Liu X (2022) Influence of PM 1 exposure on total and cause-specific respiratory diseases: a systematic review and meta-analysis. Environ Sci Pollut Res 1:1
Ilicin G, Biberoglu K, Suleymanlar G (2005) Unal S (2005) Temel iç hastalıkları (Fundamentals of internal diseases) I-II, 2nd edn. Gunes Tip Bookstore, Ankara, p 4081
Jalava PI, Wang Q, Kuuspalo K, Ruusunen J, Hao L, Fang D, Väisänen O, Ruuskanen A, Sippula O, Happo MS, Uski O (2015) Day and night variation in chemical composition and toxicological responses of size segregated urban air PM samples in a high air pollution situation. Atmos Environ 120:427–437
doi: 10.1016/j.atmosenv.2015.08.089
Kesavachandran CN, Kamal R, Bihari V et al (2015) Particulate matter in ambient air and its association with alterations in lung functions and respiratory health problems among outdoor exercisers in National Capital Region, India. Atmos Pollut Res 6(4):618–626. https://doi.org/10.5094/APR.2015.070
doi: 10.5094/APR.2015.070
Keskin SS, Dilmac E (2017) Indoor air particulate matter exposure of commuter bus passengers in Istanbul. Turkey Indoor Built Environ 26(3):337–346
doi: 10.1177/1420326X15608932
Khoza NN, Grove T, Schutte PC (2012) Worker exposure to silica dust in South African non-mining industries in Gauteng: an exploratory study. Occup Health Southern Africa 18(3):18–26
Kunal, Siddique R, Rajor A (2012) Use of cement kiln dust in cement concrete and its leachate characteristics. Resour Conserv Recycl 61:59–68
Li J, Li H, Ma Y et al (2018) Spatiotemporal distribution of indoor particulate matter concentration with a low-cost sensor network. Build Environ 127:138–147. https://doi.org/10.1016/j.buildenv.2017.11.001
doi: 10.1016/j.buildenv.2017.11.001
Li CZ, Zhao Y, Xu X (2019) Investigation of dust exposure and control practices in the construction industry: implications for cleaner production. J Clean Prod 227:810–824. https://doi.org/10.1016/j.jclepro.2019.04.174
doi: 10.1016/j.jclepro.2019.04.174
McConnell R, Berhane K, Gilliland F et al (1999) Air pollution and bronchitis syndromes in Southern California children with asthma. Environ Health Perspect 107(9):757–760
doi: 10.1289/ehp.99107757
Merefield JR (2002) Dust to dust. Newscientist, 153:1–4. https://www.newscientist.com/article/mg17523617-000-dust-to-dust/ . Accessed date 14.12.2022
Muneku E, Naidoo S (2015) Dust exposure, respiratory symptoms and disease among informal quarry workers in Lusaka Province. Zambia Occup Health Southern Africa 21(6):12–16
NIOSH (National Institute for Occupational Safety and Health) (1996) Guide the selection and use of particulate respirators. Certified under 42CFR84
NIOSH (National Institute for Occupational Safety and Health) (2017) Hierarchy of controls
Oliveira M, Izquierdo M, Querol X et al (2019) Nanoparticles from construction wastes: a problem to health and the environment. J Clean Prod 219:236–243
doi: 10.1016/j.jclepro.2019.02.096
OSHA (Occupational Safety and Health Administration, U.S. Department of Labor) (1998) OSHA standard on respiratory protection, Title 1910, Code of Federal Regulations, Part 1910.134. Federal Register 63(5):1270–1300
OSHA (Occupational Safety and Health Administration, U.S. Department of Labor) (2011) Indoor air quality in commercial and institutional buildings, pp 3430–04
Paschalidou AK, Kassomenos PA, Kelessis A (2016) Tracking the association between metro-railway construction works and PM levels in an urban Mediterranean environment. Sci Total Environ 568:1326–1332. https://doi.org/10.1016/j.scitotenv.2015.11.031
doi: 10.1016/j.scitotenv.2015.11.031
Peng R, Bell M, Geyh A et al (2009) Emergency admissions for cardiovascular and respiratory diseases and the chemical composition of fine particle air pollution. Environ Health Perspect 117:957–963
doi: 10.1289/ehp.0800185
Peters S, Thomassen Y, Fechter-Rink E et al (2009) Personal exposure to inhalable cement dust among construction workers. J Environ Mon 11(1):174–180
doi: 10.1039/B812357H
Pope C, Dockery D (2012) Health effects of fine particulate air pollution: lines that connect. J Air Waste Manag Assoc 56(6):709–742. https://doi.org/10.1080/10473289.2006.10464485
doi: 10.1080/10473289.2006.10464485
Rumchev K, Broeck V, Spickett J (2003) Indoor air quality in university laboratories. Environ Health 3:11–19
Samet J, Dominici F, Curriero F et al (2000) Fine particulate air pollution and mortality in 20 U.S. cities. N Engl J Med 343(24):1742–1749
doi: 10.1056/NEJM200012143432401
Sánchez-Soberón F, Rovira J, Sierra J et al (2019) Seasonal characterization and dosimetry-assisted risk assessment of indoor particulate matter collected in different schools. Environ Res 175:287–296
doi: 10.1016/j.envres.2019.05.035
Scheepers PT, Van Wel L, Beckmann G, Anzion RB (2017) Chemical characterization of the indoor air quality of a university hospital: penetration of outdoor air pollutants. Int J Environ Res Public Health 14(5):497
doi: 10.3390/ijerph14050497
Tian G, Wang J, Lu Z et al (2019) Indirect effect of PM1 on endothelial cells via inducing the release of respiratory inflammatory cytokines. Toxico Vitro 57:203–210
doi: 10.1016/j.tiv.2019.03.013
Tong R, Cheng M, Zhang L et al (2018) The construction dust-induced occupational health risk using Monte-Carlo simulation. J Clean Prod 184:598–608. https://doi.org/10.1016/j.jclepro.2018.02.286
doi: 10.1016/j.jclepro.2018.02.286
TSI Sidepak™ AM510 (2012) Personal aerosol monitor theory of operation. Application Note ITI-085, https://www.tsi.com/getmedia/7652d9c7-e110-4208-a37c-05210cbe2cc1/ITI-085?ext=.pdf . Accessed date 13.02.2023
Ugranli T, Toprak M, Gursoy G et al (2015) Indoor environmental quality in chemistry and chemical engineering laboratories at Izmir Institute of Technology. Atmos Pollut Research 6(1):147–153. https://doi.org/10.5094/APR.2015.017
doi: 10.5094/APR.2015.017
Valavanidis A, Vatista M (2006) Indoor air quality measurements in the chemistry department building of the University of Athens. Indoor Built Environ 15:595–605. https://doi.org/10.1177/1420326X06073182
doi: 10.1177/1420326X06073182
Weichenthal SA, Godri-Pollitt K, Villeneuve PJ (2013) PM2.5 oxidant defense and cardiorespiratory health: a review. Environ Health 12(1):40
doi: 10.1186/1476-069X-12-40
WHO (World Health Organization) (2005) Air quality guidelines. ISBN 92(890):219
WHO (World Health Organization) (1999) Hazard prevention and control in the work environment: airborne dust
Yan H, Ding G, Zhang Y et al (2018) Measurement and influencing factors analysis of PM10 emissions in construction sites. Proceedings of the ICCREM 2018, Charleston, South Carolina, USA
Yang Y, Reniers G, Chen G, Goerlandt F (2019) A bibliometric review of laboratory safety in universities. Saf Sci 120:14–24
doi: 10.1016/j.ssci.2019.06.022
Yang M, Guo YM, Bloom MS, Dharmagee SC, Morawska L, Heinrich J, Jalaludin B, Markevychd I, Knibbsf LD, Lin S, Lan SH (2020) Is PM1 similar to PM2.5? A new insight into the association of PM1 and PM2.5 with children’s lung function. Environ Int 145:106092
doi: 10.1016/j.envint.2020.106092
Yu Z, Timko MT, Herndon SC et al (2019) Mode-specific, semi-volatile chemical composition of particulate matter emissions from a commercial gas turbine aircraft engine. Atmos Environ 218:116974
doi: 10.1016/j.atmosenv.2019.116974
Yuan H, Lu W, Hao JJ (2013) The evolution of construction waste sorting on-site. Renew Sust Energ Rev 20:483–490. https://doi.org/10.1016/j.rser.2012.12.012
doi: 10.1016/j.rser.2012.12.012
Zhao X, Cheng SY, Tian G et al (2007) Construction fugitive dust pollution and control in Beijing. J Beijing Univ Technol 33(10):1086–1090
Zhou H, Zhao H, Hu J et al (2019) Primary particulate matter emissions and estimates of secondary organic aerosol formation potential from the exhaust of a China V diesel engine. Atmos Environ 218:116987
doi: 10.1016/j.atmosenv.2019.116987