Fighting the scanner effect in brain MRI segmentation with a progressive level-of-detail network trained on multi-site data.
3D segmentation
Brain MRI
Multi-site learning
Progressive level-of-detail architecture
Journal
Medical image analysis
ISSN: 1361-8423
Titre abrégé: Med Image Anal
Pays: Netherlands
ID NLM: 9713490
Informations de publication
Date de publication:
17 Jan 2024
17 Jan 2024
Historique:
received:
16
02
2023
revised:
30
10
2023
accepted:
12
01
2024
medline:
19
1
2024
pubmed:
19
1
2024
entrez:
19
1
2024
Statut:
aheadofprint
Résumé
Many clinical and research studies of the human brain require accurate structural MRI segmentation. While traditional atlas-based methods can be applied to volumes from any acquisition site, recent deep learning algorithms ensure high accuracy only when tested on data from the same sites exploited in training (i.e., internal data). Performance degradation experienced on external data (i.e., unseen volumes from unseen sites) is due to the inter-site variability in intensity distributions, and to unique artefacts caused by different MR scanner models and acquisition parameters. To mitigate this site-dependency, often referred to as the scanner effect, we propose LOD-Brain, a 3D convolutional neural network with progressive levels-of-detail (LOD), able to segment brain data from any site. Coarser network levels are responsible for learning a robust anatomical prior helpful in identifying brain structures and their locations, while finer levels refine the model to handle site-specific intensity distributions and anatomical variations. We ensure robustness across sites by training the model on an unprecedentedly rich dataset aggregating data from open repositories: almost 27,000 T1w volumes from around 160 acquisition sites, at 1.5 - 3T, from a population spanning from 8 to 90 years old. Extensive tests demonstrate that LOD-Brain produces state-of-the-art results, with no significant difference in performance between internal and external sites, and robust to challenging anatomical variations. Its portability paves the way for large-scale applications across different healthcare institutions, patient populations, and imaging technology manufacturers. Code, model, and demo are available on the project website.
Identifiants
pubmed: 38241763
pii: S1361-8415(24)00015-X
doi: 10.1016/j.media.2024.103090
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
103090Informations de copyright
Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Lars Muckli reports financial support was provided by EU Horizon 2020 Framework Programme for Research and Innovation.