On the Determination of Lagrange Multipliers for a Weighted LASSO Problem Using Geometric and Convex Analysis Techniques.

Compressed Sensing Convex optimization LASSO Lagrange duality MRI Tuning parameters

Journal

Applied mathematics and optimization
ISSN: 0095-4616
Titre abrégé: Appl Math Optim
Pays: United States
ID NLM: 9875919

Informations de publication

Date de publication:
2024
Historique:
accepted: 12 12 2023
medline: 23 1 2024
pubmed: 23 1 2024
entrez: 23 1 2024
Statut: ppublish

Résumé

Compressed Sensing (CS) encompasses a broad array of theoretical and applied techniques for recovering signals, given partial knowledge of their coefficients, cf. Candés (C. R. Acad. Sci. Paris, Ser. I

Identifiants

pubmed: 38261892
doi: 10.1007/s00245-023-10096-0
pii: 10096
pmc: PMC10794441
doi:

Types de publication

Journal Article

Langues

eng

Pagination

31

Informations de copyright

© The Author(s) 2024.

Déclaration de conflit d'intérêts

Conflict of interestThe authors have not disclosed any competing interests.

Références

Nature. 2014 Dec 4;516(7529):74-7
pubmed: 25471883
Magn Reson Med. 2007 Dec;58(6):1182-95
pubmed: 17969013
Magn Reson Med. 2004 Mar;51(3):559-67
pubmed: 15004798
Magn Reson Med. 2018 Feb;79(2):826-838
pubmed: 28497486
Opt Express. 2009 Jul 20;17(15):13040-9
pubmed: 19654708
Opt Lett. 2010 Mar 15;35(6):871-3
pubmed: 20237627
Prog Neurobiol. 2020 Nov;194:101885
pubmed: 32653462
Nat Methods. 2012 Apr 22;9(7):721-3
pubmed: 22522657
Magn Reson Med. 2019 Dec;82(6):2118-2132
pubmed: 31321816
Magn Reson Med. 2009 Jun;61(6):1434-40
pubmed: 19353675
Opt Express. 2010 Oct 11;18(21):22010-9
pubmed: 20941102
Magn Reson Med. 2021 Sep;86(3):1403-1419
pubmed: 33963779
Phys Med Biol. 2009 May 7;54(9):2791-805
pubmed: 19369711
IEEE Trans Image Process. 2014 Dec;23(12):4954-67
pubmed: 25265611

Auteurs

Gianluca Giacchi (G)

Università di Bologna, Dipartimento di Matematica, Piazza di Porta San Donato 5, 40126 Bologna, Italy.
Institute of Systems Engineering, School of Engineering, HES-SO Valais-Wallis, Rue de l'Industrie 23, 1950 Sion, Switzerland.
Lausanne University Hospital and University of Lausanne, Lausanne, Department of Diagnostic and Interventional Radiology, Rue du Bugnon 46, Lausanne, 1011 Switzerland.
The Sense Innovation and Research Center, Avenue de Provence 82 1007, Lausanne and Ch. de l'Agasse 5, 1950 Sion, Switzerland.

Bastien Milani (B)

Lausanne University Hospital and University of Lausanne, Lausanne, Department of Diagnostic and Interventional Radiology, Rue du Bugnon 46, Lausanne, 1011 Switzerland.

Benedetta Franceschiello (B)

Institute of Systems Engineering, School of Engineering, HES-SO Valais-Wallis, Rue de l'Industrie 23, 1950 Sion, Switzerland.
The Sense Innovation and Research Center, Avenue de Provence 82 1007, Lausanne and Ch. de l'Agasse 5, 1950 Sion, Switzerland.

Classifications MeSH