Decreased femur tunnel widening after augmented suspensory fixation compared to suspensory fixation for single bundle hamstring ACL reconstruction.

ACL Arthroscopy Femur endo button with screw Knee Single bundle hamstring Tunnel width

Journal

Journal of clinical orthopaedics and trauma
ISSN: 0976-5662
Titre abrégé: J Clin Orthop Trauma
Pays: India
ID NLM: 101559469

Informations de publication

Date de publication:
Jan 2024
Historique:
received: 27 09 2023
revised: 15 11 2023
accepted: 30 12 2023
pmc-release: 30 12 2024
medline: 26 1 2024
pubmed: 26 1 2024
entrez: 26 1 2024
Statut: epublish

Résumé

Tunnel widening after Anterior cruciate ligament (ACL) reconstruction using a hamstring graft is known to occur at follow-up. Our study aimed to investigate the effect of suspensory fixation augmentation using an interference screw on tunnel widening in single-bundle hamstring ACL reconstruction. 48 patients who had single bundle ACL reconstruction with femoral fixed loop fixation technique in 15 knees, and, fixed loop with augmented aperture (bio screw) fixation in 33 knees were analyzed. The width of the tunnel was measured using radiographs immediate post-op and at follow-up within 1 year. Computerized Tomogram (CT) measurements of the tunnels and functional scores were also done with overall follow-up for the fixed loop group being 21.33 months (Standard Deviation (SD)11.14) and the Augmentation group 9.12 months (SD 3.83). Midpoint femur tunnel widening was reduced in the augmentation group, with measurements of 0.74 (SD 1.05) mm Antero Posterior (AP) and 1.01 (SD 1.04) mm in the Lateral view, compared to 1.54 (SD 1.48) mm AP and 1.79 (SD1.47 mm) in the Lateral for the fixed button group. The radiological widening was considerably less in the augmentation group with a p-value of 0.07. AP aperture widening in the augmentation group was 1.25(SD 1.10 mm), and 1.09(SD0.98) mm in the lateral view. The fixed button-only group measured 1.53 (SD1.30) mm in the AP, and 1.65 (SD 1.29) mm in the lateral view, both of which were not statistically significant. The follow-up Lysholm and International Knee Documentation Committee (IKDC) scores were similar for the 2 groups. Femoral tunnel midpoint and aperture widening were reduced with the fixed loop with aperture (bio screw) augmentation technique for hamstring grafts in single bundle ACL fixation within 1 year with comparable functional scores. 4.

Sections du résumé

Background UNASSIGNED
Tunnel widening after Anterior cruciate ligament (ACL) reconstruction using a hamstring graft is known to occur at follow-up. Our study aimed to investigate the effect of suspensory fixation augmentation using an interference screw on tunnel widening in single-bundle hamstring ACL reconstruction.
Methods UNASSIGNED
48 patients who had single bundle ACL reconstruction with femoral fixed loop fixation technique in 15 knees, and, fixed loop with augmented aperture (bio screw) fixation in 33 knees were analyzed. The width of the tunnel was measured using radiographs immediate post-op and at follow-up within 1 year. Computerized Tomogram (CT) measurements of the tunnels and functional scores were also done with overall follow-up for the fixed loop group being 21.33 months (Standard Deviation (SD)11.14) and the Augmentation group 9.12 months (SD 3.83).
Results UNASSIGNED
Midpoint femur tunnel widening was reduced in the augmentation group, with measurements of 0.74 (SD 1.05) mm Antero Posterior (AP) and 1.01 (SD 1.04) mm in the Lateral view, compared to 1.54 (SD 1.48) mm AP and 1.79 (SD1.47 mm) in the Lateral for the fixed button group. The radiological widening was considerably less in the augmentation group with a p-value of 0.07. AP aperture widening in the augmentation group was 1.25(SD 1.10 mm), and 1.09(SD0.98) mm in the lateral view. The fixed button-only group measured 1.53 (SD1.30) mm in the AP, and 1.65 (SD 1.29) mm in the lateral view, both of which were not statistically significant. The follow-up Lysholm and International Knee Documentation Committee (IKDC) scores were similar for the 2 groups.
Conclusion UNASSIGNED
Femoral tunnel midpoint and aperture widening were reduced with the fixed loop with aperture (bio screw) augmentation technique for hamstring grafts in single bundle ACL fixation within 1 year with comparable functional scores.
Level of evidence UNASSIGNED
4.

Identifiants

pubmed: 38274644
doi: 10.1016/j.jcot.2023.102331
pii: S0976-5662(23)00239-4
pmc: PMC10806195
doi:

Types de publication

Journal Article

Langues

eng

Pagination

102331

Informations de copyright

© 2023 Delhi Orthopedic Association. All rights reserved.

Déclaration de conflit d'intérêts

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Sam James Daniel (SJ)

Department of Orthopaedics, Unit 2, Christian Medical College, Vellore, Tamil Nadu, 632004, India.

Jozy Timothy (J)

Department of Orthopaedics, Unit 2, Christian Medical College, Vellore, Tamil Nadu, 632004, India.

Madhavi Kandagaddala (M)

Department of Radiology, Christian Medical College, Vellore, Tamil Nadu, 632004, India.

K Reka (K)

Department of Biostatistics, Christian Medical College, Vellore, Tamil Nadu, 632002, India.

Pradeep Mathew Poonnoose (PM)

Department of Orthopaedics, Unit 2, Christian Medical College, Vellore, Tamil Nadu, 632004, India.

Anil Thomas Oommen (AT)

Department of Orthopaedics, Unit 2, Christian Medical College, Vellore, Tamil Nadu, 632004, India.

Classifications MeSH