BMI-Adapted Double Low-Dose Dual-Source Aortic CT for Endoleak Detection after Endovascular Repair: A Prospective Intra-Individual Diagnostic Accuracy Study.

EVAR surveillance endoleak imaging low-dose CT quantitative analysis

Journal

Diagnostics (Basel, Switzerland)
ISSN: 2075-4418
Titre abrégé: Diagnostics (Basel)
Pays: Switzerland
ID NLM: 101658402

Informations de publication

Date de publication:
27 Jan 2024
Historique:
received: 05 12 2023
revised: 19 01 2024
accepted: 25 01 2024
medline: 10 2 2024
pubmed: 10 2 2024
entrez: 10 2 2024
Statut: epublish

Résumé

To assess the diagnostic accuracy of BMI-adapted, low-radiation and low-iodine dose, dual-source aortic CT for endoleak detection in non-obese and obese patients following endovascular aortic repair. In this prospective single-center study, patients referred for follow-up CT after endovascular repair with a history of at least one standard triphasic (native, arterial and delayed phase) routine CT protocol were enrolled. Patients were divided into two groups and allocated to a BMI-adapted (group A, BMI < 30 kg/m Seventy-five patients were included in the study (mean age 73 ± 8 years, 63 (84%) male). Endoleaks were diagnosed in 20 (26.7%) patients, 11 of 53 (20.8%) in group A and 9 of 22 (40.9%) in group B. Two radiologists achieved an overall diagnostic accuracy of 98.7% and 97.3% for endoleak detection, with 100% in group A and 95.5% and 90.9% in group B. All examinations were diagnostic. The DLCT protocol reduced the effective dose from 10.0 ± 3.6 mSv to 6.1 ± 1.5 mSv ( Optimized double low-dose dual-source aortic CT with VNC, arterial and delayed phase images demonstrated high diagnostic accuracy for endoleak detection and significant radiation and iodine dose reductions in both obese and non-obese patients compared to the reference standard of triple phase, standard radiation and iodine dose aortic CT.

Identifiants

pubmed: 38337796
pii: diagnostics14030280
doi: 10.3390/diagnostics14030280
pii:
doi:

Types de publication

Journal Article

Langues

eng

Auteurs

Claudius Melzig (C)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Sibylle Hartmann (S)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Andrea Steuwe (A)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Department of Diagnostic and Interventional Radiology, Medical Faculty and University Hospital, Heinrich Heine University Düsseldorf, 40225 Düsseldorf, Germany.

Jan Egger (J)

Institute for AI in Medicine, University Medicine Essen, 45147 Essen, Germany.

Thuy D Do (TD)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Philipp Geisbüsch (P)

Department of Vascular and Endovascular Surgery, Heidelberg University Hospital, 69120 Heidelberg, Germany.
Department of Vascular and Endovascular Surgery, Klinikum Stuttgart, Katharinenhospital, 70199 Stuttgart, Germany.

Hans-Ulrich Kauczor (HU)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Fabian Rengier (F)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Matthias A Fink (MA)

Clinic for Diagnostic and Interventional Radiology, Heidelberg University Hospital, 69120 Heidelberg, Germany.

Classifications MeSH