Comparison of cutout risk factors between single- and doublescrew proximal nails in intertrochanteric femur fractures - a multicentric study.

internal fixation nailing postoperative complication proximal femoral fractures

Journal

Medicinski glasnik : official publication of the Medical Association of Zenica-Doboj Canton, Bosnia and Herzegovina
ISSN: 1840-2445
Titre abrégé: Med Glas (Zenica)
Pays: Bosnia and Herzegovina
ID NLM: 101250177

Informations de publication

Date de publication:
01 Feb 2024
Historique:
received: 23 10 2023
accepted: 09 11 2023
medline: 11 2 2024
pubmed: 11 2 2024
entrez: 11 2 2024
Statut: aheadofprint

Résumé

Aim Significant risk factors for femoral nail cutout are well-documented, primarily in the context of single-screw proximal nails. However, it remains uncertain whether those same risk factors are applicable when considering different implant devices. The aim of this retrospective cohort study was to compare cutout risk factors between single- versus double-screw proximal femoral nails. Methods Patients over the age of 75 with intertrochanteric femur fractures (AO Classification 31-A1 or 31-A2) were included in the multicentre study. A study group was treated with a double-screw nail, while a control group received single-screw device. Demographic data, surgical time (min), fracture pattern, distal locking, reduction quality, comorbidities, tip-apex distance (TAD) and 12-month functional scores was collected. Results Two hundred patients were enrolled, 100 for each group. Nine patients experienced a cutout complication, five in the study and four in the control group. The main differences were in distal locking configurations (p<0.05) and in TAD values (p<0.05). The TAD value was higher in the study than in the control group (30.40±0.89 versus 26.79±1.79). No differences at 12-month follow up were reported according to functional scores. Conclusion This study provides insights into the choice of nail systems for intertrochanteric femur fractures, highlighting the importance of distal locking configurations and TAD values. The double screw nail exhibits quite a tolerance by having a higher average TAD value. These findings may guide clinical decisionmaking in the treatment of this challenging fracture type.

Identifiants

pubmed: 38341752
doi: 10.17392/1683-23
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

208-213

Informations de copyright

Copyright© by the Medical Assotiation of Zenica-Doboj Canton.

Auteurs

Michele Coviello (M)

Orthopaedics Unit, Department of Clinical and Experimental Medicine, Faculty of Medicine and Surgery, University of Foggia, Policlinico Riuniti di Foggia, Foggia, Italy.

Antonella Abate (A)

Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy.

Giovanni Vicenti (G)

Department of Basic Medical Science, Neuroscience and Sensory Organs, Azienda Ospedaliero Universitaria Consorziale Policlinico, Bari, Italy.

Francesco Ippolito (F)

Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy.

Vittorio Nappi (V)

Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy.

Andrea Michele Abbaticchio (AM)

Department of Basic Medical Science, Neuroscience and Sensory Organs, Azienda Ospedaliero Universitaria Consorziale Policlinico, Bari, Italy.

Elio Caiaffa (E)

Department of Basic Medical Science, Neuroscience and Sensory Organs, Azienda Ospedaliero Universitaria Consorziale Policlinico, Bari, Italy.

Giulia Colasuonno (G)

Department of Basic Medical Science, Neuroscience and Sensory Organs, Azienda Ospedaliero Universitaria Consorziale Policlinico, Bari, Italy.

Vincenzo Caiaffa (V)

Orthopaedic and Traumatology Unit, "Di Venere" Hospital, Bari, Italy.

Giuseppe Solarino (G)

Department of Basic Medical Science, Neuroscience and Sensory Organs, Azienda Ospedaliero Universitaria Consorziale Policlinico, Bari, Italy.

Classifications MeSH