Quality control data management with unity real-time in molecular virology.
QC
QC management
QC software
Quality control
Journal
Journal of clinical virology : the official publication of the Pan American Society for Clinical Virology
ISSN: 1873-5967
Titre abrégé: J Clin Virol
Pays: Netherlands
ID NLM: 9815671
Informations de publication
Date de publication:
Apr 2024
Apr 2024
Historique:
received:
23
07
2023
revised:
12
12
2023
accepted:
11
02
2024
medline:
18
3
2024
pubmed:
17
2
2024
entrez:
17
2
2024
Statut:
ppublish
Résumé
Quality control (QC) is one component of an overarching quality management system (QMS) that aims at assuring laboratory quality and patient safety. QC data must be acceptable prior to reporting patients' results. Traditionally, QC statistics, records, and corrective actions were tracked at the Johns Hopkins Molecular Virology Laboratory using Microsoft Excel. Unity Real-Time (UnityRT), a QMS software (Bio-Rad Laboratories), which captures and analyzes QC data by instrument and control lot per assay, was implemented and its impact on the workflow was evaluated. The clinical utility of real-time QC monitoring using UnityRT is highlighted with a case of subtle QC trending of HIV-1 quantitative control results. A comprehensive workflow analysis was performed, with a focus on Epstein Barr Virus (EBV) and BKV quantitative viral load testing (Roche cobas 6800). The number of QC steps and time to complete each step were assessed before and after implementing UnityRT. Our assessment of monthly QC data review revealed a total of 10 steps over 57 min when using Microsoft Excel, versus 6 steps over 11 min when using UnityRT. HIV-1 QC monitoring revealed subtle trending of the low positive control above the mean from November to December 2022, correlating with a change in the reagent kit lot. This associated with a shift in patients' results from positives below the lower limit of quantification to positives between 20 and 100 copies/mL. UnityRT consolidated QC analyses, monitoring, and tracking corrective actions. UnityRT was associated with significant time savings, which along with the interfaced feature of the QC capture and data analysis, have improved the workflow and reduced the risk of laboratory errors. The HIV-1 case revealed the value of the real-time monitoring of QC.
Identifiants
pubmed: 38367294
pii: S1386-6532(24)00017-9
doi: 10.1016/j.jcv.2024.105655
pii:
doi:
Types de publication
Case Reports
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
105655Informations de copyright
Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: HHM reports research collaborations with Bio-Rad, Qiagen, and Hologic, received honoraria from BD diagnostics and Bio-Rad, and serves on the advisory board for Seegene. BN is an employee of Bio-Rad Laboratories. At the time of the study, DN was an employee of Bio-Rad Laboratories.