Diagnostic accuracy of intraoperative neuromonitoring in transcarotid artery revascularization.

CT Angiography EEG Evoked Potentials, Somatosensory Stent Stroke

Journal

Journal of neurointerventional surgery
ISSN: 1759-8486
Titre abrégé: J Neurointerv Surg
Pays: England
ID NLM: 101517079

Informations de publication

Date de publication:
20 Feb 2024
Historique:
received: 19 11 2023
accepted: 31 01 2024
medline: 21 2 2024
pubmed: 21 2 2024
entrez: 20 2 2024
Statut: aheadofprint

Résumé

In recent years, transcarotid artery revascularization (TCAR) has emerged as a safe and effective alternative to carotid artery stenting. While intraoperative neuromonitoring (IONM) techniques such as electroencephalogram (EEG) and somatosensory evoked potentials (SSEPs) are often employed during TCAR, there is limited research on their diagnostic accuracy. The authors retrospectively reviewed a multi-institutional IONM database of TCAR procedures performed with EEG and SSEP monitoring. A total of 516 TCAR procedures were included in this study. Significant changes in EEG and/or SSEPs, surgeon's interventions, resolution of significant changes, and immediate postoperative neurological outcome were documented. Sensitivity, specificity, positive and negative predictive values were calculated. The incidence of intraoperative onset new neurologic deficit was 0.4%. Significant changes in EEG and/or SSEPs occurred in 5.4% of the cases. Of the cases with IONM alerts, 78.5% returned to baseline with a surgical or hemodynamic intervention. From the cases with unresolved IONM alerts, 33.3% woke up with a new neurological deficit. The overall sensitivity and specificity for IONM was 100% and 99.2%, respectively. The positive predictive value was 33.3% and the negative predictive value was 100%. IONM during TCAR offers high sensitivity and specificity in predicting postoperative outcome. Patients with resolved IONM alerts had immediate neurological outcomes that were comparable to those who had no IONM alerts.

Sections du résumé

BACKGROUND BACKGROUND
In recent years, transcarotid artery revascularization (TCAR) has emerged as a safe and effective alternative to carotid artery stenting. While intraoperative neuromonitoring (IONM) techniques such as electroencephalogram (EEG) and somatosensory evoked potentials (SSEPs) are often employed during TCAR, there is limited research on their diagnostic accuracy.
METHODS METHODS
The authors retrospectively reviewed a multi-institutional IONM database of TCAR procedures performed with EEG and SSEP monitoring. A total of 516 TCAR procedures were included in this study. Significant changes in EEG and/or SSEPs, surgeon's interventions, resolution of significant changes, and immediate postoperative neurological outcome were documented. Sensitivity, specificity, positive and negative predictive values were calculated.
RESULTS RESULTS
The incidence of intraoperative onset new neurologic deficit was 0.4%. Significant changes in EEG and/or SSEPs occurred in 5.4% of the cases. Of the cases with IONM alerts, 78.5% returned to baseline with a surgical or hemodynamic intervention. From the cases with unresolved IONM alerts, 33.3% woke up with a new neurological deficit. The overall sensitivity and specificity for IONM was 100% and 99.2%, respectively. The positive predictive value was 33.3% and the negative predictive value was 100%.
CONCLUSIONS CONCLUSIONS
IONM during TCAR offers high sensitivity and specificity in predicting postoperative outcome. Patients with resolved IONM alerts had immediate neurological outcomes that were comparable to those who had no IONM alerts.

Identifiants

pubmed: 38378240
pii: jnis-2023-021282
doi: 10.1136/jnis-2023-021282
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© Author(s) (or their employer(s)) 2024. No commercial re-use. See rights and permissions. Published by BMJ.

Déclaration de conflit d'intérêts

Competing interests: The authors CD, DN and BC are employees of Nuvasive/Globus Medical and CM is a consultant of Penumbra and Silk Road Medical.

Auteurs

Cinira Diogo (C)

Physiology and Neurobiology, University of Connecticut, Storrs, Connecticut, USA ciniraa.diogo@gmail.com.
Nuvasive Clinical Services, Columbia, Maryland, USA.

Doohwan Na (D)

Nuvasive Clinical Services, Columbia, Maryland, USA.

Nanthiya Sujijantarat (N)

Neurosurgery, Yale University, New Haven, Connecticut, USA.

Charles Matouk (C)

Neurosurgery, Yale University, New Haven, Connecticut, USA.

Brooke Callahan (B)

Nuvasive Clinical Services, Columbia, Maryland, USA.

Classifications MeSH