Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
23 Feb 2024
Historique:
received: 28 11 2023
accepted: 16 02 2024
medline: 24 2 2024
pubmed: 24 2 2024
entrez: 23 2 2024
Statut: epublish

Résumé

Nuclear spin hyperpolarization increases the sensitivity of magnetic resonance dramatically, enabling many new applications, including real-time metabolic imaging. Parahydrogen-based signal amplification by reversible exchange (SABRE) was employed to hyperpolarize [1-

Identifiants

pubmed: 38396023
doi: 10.1038/s41598-024-54770-x
pii: 10.1038/s41598-024-54770-x
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

4468

Subventions

Organisme : German Research Foundation
ID : BU 2694/6-1
Organisme : German Research Foundation
ID : BU 2694/6-1
Organisme : German Research Foundation
ID : PL 576/6-1
Organisme : German Research Foundation
ID : PR 1868/3-1
Organisme : German Research Foundation
ID : BU 2694/6-1
Organisme : German Federal Ministry of Education and Research (BMBF) within the framework of the e:Med research and funding concept
ID : 01ZX1915C
Organisme : Zukunftsprogramm Wirtschaft Schleswig Holstein
ID : 122-09-053
Organisme : Humboldt Foundation, Friedrich Wilhelm Bessel Award
ID : Humboldt ID 1197893

Informations de copyright

© 2024. The Author(s).

Références

Sarracanie, M. et al. Low-cost high-performance MRI. Sci. Rep. 5, (2015).
Inglis, B. et al. MRI of the human brain at 130 microtesla. Proc. Natl. Acad. Sci. 110, 19194–19201 (2013).
pubmed: 24255111 pmcid: 3845112
Kraus, R., Espy, M. & Magnelind, P. Ultra-low Field Nuclear Magnetic Resonance: A New Mri Regime (Oxford Univ Pr, Oxford, 2014).
Körber, R. et al. SQUIDs in biomagnetism: A roadmap towards improved healthcare. Supercond. Sci. Technol. 29, 113001 (2016).
Buckenmaier, K. et al. Mutual benefit achieved by combining ultralow-field magnetic resonance and hyperpolarizing techniques. Rev. Sci. Instrum. 89, 125103 (2018).
pubmed: 30599552
Nelson, S. J. et al. Metabolic imaging of patients with prostate cancer using hyperpolarized [1–13C]Pyruvate. Sci. Transl. Med. 5, 198–108 (2013).
Månsson, S., Petersson, J. S. & Scheffler, K. Fast metabolite mapping in the pig heart after injection of hyperpolarized 13C-pyruvate with low-flip angle balanced steady-state free precession imaging. Magn. Reson. Med. 68, 1894–1899 (2012).
pubmed: 22294528
Jaklevic, R. C., Lambe, J., Silver, A. H. & Mercereau, J. E. Quantum interference effects in Josephson tunneling. Phys. Rev. Lett. 12, 159–160 (1964).
Hari, R. & Salmelin, R. Magnetoencephalography: From SQUIDs to neuroscience. NeuroImage 61, 386–396 (2012).
pubmed: 22166794
Lee, Y.-H. et al. SQUID systems for magnetocardiographic applications. Prog. Superconduct. Cryogeni. 9, 1–6 (2007).
Banks, R. J. The magnetotelluric sounding method. Methods in Geochemistry and Geophysics, Vol. 15, A. A. Kaufman and G. V. Keller, Elsevier Scientific, Amsterdam, 1981 596 pp., US\textdollar144.00. Geophys. J. Int. 66, 753–755 (1981).
Busch, S. et al. Measurements of T1-relaxation in ex vivo prostate tissue at 132 μT. Magn. Reson. Med. 67, 1138–1145 (2012).
pubmed: 22294500
McDermott, R. et al. Microtesla MRI with a superconducting quantum interference device. Proc. Natl. Acad. Sci. 101, 7857–7861 (2004).
pubmed: 15141077 pmcid: 419521
Vesanen, P. T., Nieminen, J. O., Zevenhoven, K. C. J., Hsu, Y.-C. & Ilmoniemi, R. J. Current-density imaging using ultra-low-field MRI with zero-field encoding. Magn. Reson. Imaging 32, 766–770 (2014).
pubmed: 24731792
Hömmen, P., Storm, J.-H., Höfner, N. & Körber, R. Demonstration of full tensor current density imaging using ultra-low field MRI. Magn. Reson. Imaging 60, 137–144 (2019).
pubmed: 30898636
Espy, M. et al. Ultra-low-field MRI for the detection of liquid explosives. Supercond. Sci. Technol. 23, 034023 (2010).
Mößle, M. et al. SQUID-detected microtesla MRI in the presence of metal. J. Magn. Reson. 179, 146–151 (2006).
pubmed: 16310385
Espy, M., Matlashov, A. & Volegov, P. SQUID-detected ultra-low field MRI. J. Magn. Reson. 229, 127–141 (2013).
pubmed: 23452838
Zotev, V. S. et al. Microtesla MRI with dynamic nuclear polarization. J. Magn. Reson. 207, 78–88 (2010).
pubmed: 20843715 pmcid: 2956831
Golman, K. et al. Dynamic in vivo oxymetry using overhauser enhanced MR imaging. J. Magn. Reson. Imaging 12, 929–938 (2000).
pubmed: 11105032
Bidinosti, C. P., Choukeife, J., Tastevin, G., Nacher, P.-J. & Vignaud, A. MRI of the lung using hyperpolarized 3He at very low magnetic field (3 mT). MAGMA 16, 255–258 (2004).
pubmed: 15029510
Buntkowsky, G. et al. Recent advances in the application of parahydrogen in catalysis and biochemistry. RSC Adv. 12, 12477–12506 (2022).
pubmed: 35480380 pmcid: 9039419
Reineri, F. Design and testing of diagnostic MRI/MRS applications based on signal enhancement by parahydrogen-induced polarization. Anal. Sensing 2, (2022).
Hövener, J.-B. et al. Parahydrogen-based hyperpolarization for biomedicine. Angew. Chem. Int. Ed. 57, 11140–11162 (2018).
Green, R. A. et al. The theory and practice of hyperpolarization in magnetic resonance using parahydrogen. Prog. Nuclear Magn. Reson. Spectrosc. 67, 1–48 (2012).
Bowers, C. R. & Weitekamp, D. P. Transformation of symmetrization order to nuclear-spin magnetization by chemical reaction and nuclear magnetic resonance. Phys. Rev. Lett. 57, 2645–2648 (1986).
pubmed: 10033824
Eisenschmid, T. C. et al. Para hydrogen induced polarization in hydrogenation reactions. J. Am. Chem. Soc. 109, 8089–8091 (1987).
Bowers, C. R. & Weitekamp, D. P. Parahydrogen and synthesis allow dramatically enhanced nuclear alignment. J. Am. Chem. Soc. 109, 5541–5542 (1987).
Rayner, P. J. & Duckett, S. B. Signal amplification by reversible exchange (SABRE): From discovery to diagnosis. Angew. Chem. Int. Ed. 57, 6742–6753 (2018).
Buckenmaier, K. et al. Multiple quantum coherences hyperpolarized at ultra-low fields. ChemPhysChem 20, 2823–2829 (2019).
pubmed: 31536665 pmcid: 6900040
Svyatova, A. et al. X15N MRI of SLIC-SABRE hyperpolarized 15N-labelled pyridine and nicotinamide. Chem. Eur. J. 25, 8465–8470 (2019).
pubmed: 30950529
Lee, S.-J. et al. SQUID-based ultralow-field MRI of a hyperpolarized material using signal amplification by reversible exchange. Sci. Rep. 9, 12422 (2019).
pubmed: 31455823 pmcid: 6712030
Waddington, D. E. J. et al. An Overhauser-enhanced-MRI platform for dynamic free radical imaging \lessi\greaterin vivo\less/i\greater. NMR Biomed. 31, e3896 (2018).
pubmed: 29493032
Vesanen, P. T. et al. Hybrid ultra-low-field MRI and magnetoencephalography system based on a commercial whole-head neuromagnetometer. Magn. Reson. Med. 69, 1795–1804 (2012).
pubmed: 22807201
Lehmkuhl, S. et al. RASER MRI: Magnetic resonance images formed spontaneously exploiting cooperative nonlinear interaction. Sci. Adv. 8, (2022).
Hömmen, P. et al. Evaluating the performance of ultra-low-field MRI for in-vivo 3D current density imaging of the human head. Front. Phys. 8, (2020).
Theis, T. et al. Microtesla SABRE enables 10% nitrogen-15 nuclear spin polarization. Journal of the American Chemical Society 137, 1404–1407 (2015).
pubmed: 25583142 pmcid: 4333583
Truong, M. L. et al. 15N hyperpolarization by reversible exchange using SABRE-SHEATH. J. Phys. Chem. C 119, 8786–8797 (2015).
Zhivonitko, V. V., Skovpin, I. V. & Koptyug, I. V. Strong 31P nuclear spin hyperpolarization produced via reversible chemical interaction with parahydrogen. Chem. Commun. 51, 2506–2509 (2015).
Knecht, S., Kiryutin, A. S., Yurkovskaya, A. V. & Ivanov, K. L. Efficient conversion of anti-phase spin order of protons into 15N magnetisation using SLIC-SABRE. Mol. Phys. 117, 2762–2771 (2018).
Pravdivtsev, A. N. et al. Chemical exchange reaction effect on polarization transfer efficiency in SLIC-SABRE. J. Phys. Chem. A 122, 9107–9114 (2018).
pubmed: 30295488 pmcid: 6249111
Ariyasingha, N. M. et al. Quasi-resonance fluorine-19 signal amplification by reversible exchange. J. Phys. Chem. Lett. 10, 4229–4236 (2019).
pubmed: 31291106 pmcid: 6675627
Theis, T., Truong, M., Coffey, A. M., Chekmenev, E. Y. & Warren, W. S. LIGHT-SABRE enables efficient in-magnet catalytic hyperpolarization. J. Magn. Reson. 248, 23–26 (2014).
pubmed: 25299767 pmcid: 6097635
MacCulloch, K. et al. Facile hyperpolarization chemistry for molecular imaging and metabolic tracking of [1–13C]pyruvate in vivo. J. Magn. Reson. Open 16–17, 100129 (2023).
pubmed: 38090022 pmcid: 10715622
de Maissin, H. et al. In vivo metabolic imaging of [1–13C]pyruvate-d3 hyperpolarized by reversible exchange with parahydrogen. Angew. Chem. Int. Edn. n/a, e202306654 (2023).
Vázquez-Serrano, L. D., Owens, B. T. & Buriak, J. M. Catalytic olefin hydrogenation using N-heterocyclic carbene–phosphine complexes of iridium. Chem. Commun. https://doi.org/10.1039/b208403a (2002).
doi: 10.1039/b208403a
Pravdivtsev, A. N. et al. Spin polarization transfer mechanisms of SABRE: A magnetic field dependent study. J. Magn. Reson. 261, 73–82 (2015).
pubmed: 26529205
Iali, W. et al. Hyperpolarising pyruvate through signal amplification by reversible exchange (SABRE). Angew. Chem. 131, 10377–10381 (2019).
Tickner, B. J. et al. Optimisation of pyruvate hyperpolarisation using SABRE by tuning the active magnetisation transfer catalyst. Catal. Sci. Technol. 10, 1343–1355 (2020).
pubmed: 32647563 pmcid: 7315823
Adelabu, I. et al. Order-unity 13C nuclear polarization of [1–13C]pyruvate in seconds and the interplay of water and SABRE enhancement. ChemPhysChem 23 (2021).
TomHon, P. et al. Temperature cycling enables efficient 13C SABRE-SHEATH hyperpolarization and imaging of [1-13C]-pyruvate. J. Am. Chem. Soc. 144, 282–287 (2021).
pubmed: 34939421 pmcid: 8785411
Pravdivtsev, A. N. et al. LIGHT-SABRE hyperpolarizes 1–13C-pyruvate continuously without magnetic field cycling. J. Phys. Chem. C 127, 6744–6753 (2023).
Schmidt, A. B. et al. Catalyst-free aqueous hyperpolarized [1-13C]pyruvate obtained by re-dissolution signal amplification by reversible exchange. ACS Sens. 7, 3430–3439 (2022).
pubmed: 36379005 pmcid: 9983023
Iali, W., Olaru, A. M., Green, G. G. R. & Duckett, S. B. Achieving high levels of NMR-hyperpolarization in aqueous media with minimal catalyst contamination using SABRE. Chem. Eur. J. 23, 10491–10495 (2017).
pubmed: 28609572
Handbook of MRI Pulse Sequences. (Elsevier, 2004). https://doi.org/10.1016/b978-0-12-092861-3.x5000-6 .
Schmidt, A. B. et al. Over 20% carbon-13 polarization of perdeuterated pyruvate using reversible exchange with parahydrogen and spin-lock induced crossing at 50 \upmuT. J. Phys. Chem. Lett. 14, 5305–5309 (2023).
pubmed: 37267594

Auteurs

Nicolas Kempf (N)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.

Rainer Körber (R)

Physikalisch-Technische Bundesanstalt, 10587, Berlin, Germany.

Markus Plaumann (M)

Institute for Molecular Biology and Medicinal Chemistry, Medical Faculty, Otto-von-Guericke University, 39120, Magdeburg, Germany.

Andrey N Pravdivtsev (AN)

Section Biomedical Imaging, Molecular Imaging North Competence Center (MOIN CC), Department of Radiology and Neuroradiology, University Medical Center, Kiel University, 24118, Kiel, Germany.

Jörn Engelmann (J)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.

Johannes Boldt (J)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.

Klaus Scheffler (K)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.
Departement of Biomedical Magnetic Resonance, Eberhard-Karls University, 72076, Tübingen, Germany.

Thomas Theis (T)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany.
Departement of Chemistry and Physics, NC State University, Raleigh, 27695, USA.

Kai Buckenmaier (K)

High-Field Magnetic Resonance Center, Max Planck Institute for Biological Cybernetics, 72076, Tübingen, Germany. kai.buckenmaier@tuebingen.mpg.de.

Classifications MeSH