Photon-Counting Detector CT Angiography Versus Digital Subtraction Angiography in Patients with Peripheral Arterial Disease.
Digital subtraction angiography
Peripheral arterial disease
Photon-counting detector CT
Run-off CTA
Journal
Academic radiology
ISSN: 1878-4046
Titre abrégé: Acad Radiol
Pays: United States
ID NLM: 9440159
Informations de publication
Date de publication:
24 Feb 2024
24 Feb 2024
Historique:
received:
28
12
2023
revised:
23
01
2024
accepted:
05
02
2024
medline:
26
2
2024
pubmed:
26
2
2024
entrez:
25
2
2024
Statut:
aheadofprint
Résumé
This study aims to compare the diagnostic confidence of photon-counting detector CT angiography (PCD-CTA) depending on the used vascular reformatting kernels with digital subtraction angiography (DSA) as diagnostic reference standard in peripheral arterial occlusive disease (PAOD). In 39 patients, 45 lower extremity PCD-CTA with subsequent DSA were analyzed. Advanced PAOD (Fontaine stage 4) was ascertained in 77.8% of patients. CTA post-processing comprised three vascular kernels (Bv36/48/56). Objective image quality assessment included vessel attenuation, image noise, contrast-to-noise (CNR) and signal-to-noise ratios (SNR). Subjective evaluation of calcium blooming, vessel sharpness, luminal attenuation and image noise was performed by three radiologists. Diagnostic performance and concordance to DSA were assessed. The luminal attenuation remained kernel-independent constant. With sharper kernels, image noise increased substantially, while SNR and CNR decreased. Subjective reduction of calcium blooming and increased vessel sharpness were noted for the sharp Bv56 kernel. While sensitivity in stenosis quantification was comparable between kernels (81.6% vs. 81.5% vs. 81.0%, p = 0.797), specificity increased slightly higher sharpness (71.1% vs. 76.9% vs. 79.6%, p = 0.067). Diagnostic concordance of stenosis ratings compared to DSA increased likewise (Bv36 vs. Bv56, p = 0.002). Severe crural vessel calcifications had no influence on sensitivity, regardless of kernel selection. Contrarily, specificity was substantially worse in severely calcified tibial vessels but could be improved by using the sharp Bv56 kernel (Bv36 vs. Bv56 p = 0.024). Diagnostic confidence was highest for Bv56. In lower leg PCD-CTA, sharp convolution kernels increase diagnostic confidence compared to DSA by improved vessel delineation and reduced calcium blooming with acceptable image noise.
Identifiants
pubmed: 38403477
pii: S1076-6332(24)00078-3
doi: 10.1016/j.acra.2024.02.008
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare the following financial interests/personal relationships which may be considered as potential competing interests: Philipp Gruschwitz reports financial support was provided by Interdisciplinary Center of Clinical Research Würzburg. Jan-Peter Grunz reports financial support was provided by Interdisciplinary Center of Clinical Research Würzburg. Thorsten Alexander Bley reports a relationship with Siemens Healthineers that includes: consulting or advisory and speaking and lecture fees. Bernhard Petritsch reports a relationship with Siemens Healthineers that includes: consulting or advisory and speaking and lecture fees. Jan-Peter Grunz reports a relationship with Siemens Healthineers that includes: consulting or advisory and speaking and lecture fees. If there are other authors, they declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.