Patient-specific computer simulation of transcatheter aortic valve replacement in patients with previous mechanical mitral prosthesis: A case series.
FEops HEARTguide
aortic stenosis
artificial intelligence
mechanical mitral prosthesis
transcatheter heart valve
Journal
Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions
ISSN: 1522-726X
Titre abrégé: Catheter Cardiovasc Interv
Pays: United States
ID NLM: 100884139
Informations de publication
Date de publication:
26 Feb 2024
26 Feb 2024
Historique:
revised:
24
01
2024
received:
29
11
2023
accepted:
11
02
2024
medline:
26
2
2024
pubmed:
26
2
2024
entrez:
26
2
2024
Statut:
aheadofprint
Résumé
Transcatheter aortic valve replacement performed in patients with previously implanted mechanical mitral prosthesis represents a high risk procedure with several potential complications. We report a systematic use of a prediction model based on artificial intelligence to plan the interventional strategy in this challenging scenario.
Types de publication
Case Reports
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024 Wiley Periodicals LLC.
Références
Vahanian A, Beyersdorf F, Praz F, et al. 2021 ESC/EACTS guidelines for the management of valvular heart disease. Eur Heart J. 2022;43(7):561-632.
Kalogeropoulos AS, Redwood SR, Allen CJ, et al. A 20-year journey in transcatheter aortic valve implantation: evolution to current eminence. Front Cardiovasc Med. 2022;9:971762.
Schultz C, Rodriguez-Olivares R, Bosmans J, et al. Patient-specific image-based computer simulation for the prediction of valve morphology and calcium displacement after TAVI with the Medtronic CoreValve and the Edwards SAPIEN valve. EuroIntervention. 2016;11(9):1044-1052.
Hokken TW, Wienemann H, Dargan J, et al. Clinical value of CT-derived simulations of transcatheter-aortic-valve-implantation in challenging anatomies the PRECISE-TAVI trial. Catheter Cardiovasc Interv. 2023;102:1140-1148.
Chen Y, Zhu G, Liu X, et al. Comparison of cusp-overlap projection and standard three-cusp coplanar view during self-expanding transcatheter aortic valve replacement: a systematic review and meta-analysis. Front Cardiovasc Med. 2022;9:927642.
Rankin JS, Hammill BG, Ferguson Jr., TB, et al. Determinants of operative mortality in valvular heart surgery. J Thorac Cardiovasc Surg. 2006;131(3):547-557. doi:10.1016/j.jtcvs.2005.10.041
Bajaj A, Sethi A, Rathor P, Sehgal V, Pancholy S. Impact of previous cardiac surgery on patients undergoing transcatheter aortic valve implantation: a meta-analysis. Heart Lung. 2016;45(4):350-358.
Baldetti L, Giannini F, Van Mieghem N, et al. Outcome of patients undergoing transcatheter implantation of aortic valve with previous mitral valve prosthesis (OPTIMAL) study. Can J Cardiol. 2019;35(7):866-874.
Dumonteil N, Marcheix B, Berthoumieu P, et al. Transfemoral aortic valve implantation with pre-existent mechanical mitral prosthesis. JACC Cardiovasc Interv. 2009;2(9):897-898.
Amat-Santos IJ, Cortés C, Nombela Franco L, et al. Prosthetic mitral surgical valve in transcatheter aortic valve Replacement Recipients. JACC Cardiovasc Interv. 2017;10(19):1973-1981.
Tanaka M, Yanagisawa R, Yashima F, et al. OCEAN-TAVI investigators. Previously implanted mitral surgical prosthesis in patients undergoing transcatheter aortic valve implantation: procedural outcome and morphologic assessment using multidetector computed tomography. PLoS One. 2019;14(12):e0226512.
Tébar Márquez D, Moreno R, Galeote G, et al. Transcatheter aortic valve with a novel self-expandable device in patients with previous mechanical mitral valve prosthesis. Catheter Cardiovasc Interv. 2022;100(7):1286-1290.