Pencil beam scanning proton therapy for mediastinal lymphomas in deep inspiration breath-hold: a retrospective assessment of plan robustness.


Journal

Acta oncologica (Stockholm, Sweden)
ISSN: 1651-226X
Titre abrégé: Acta Oncol
Pays: England
ID NLM: 8709065

Informations de publication

Date de publication:
28 Feb 2024
Historique:
received: 18 10 2023
accepted: 29 01 2024
medline: 28 2 2024
pubmed: 28 2 2024
entrez: 28 2 2024
Statut: epublish

Résumé

The aim of this study was to evaluate pencil beam scanning (PBS) proton therapy (PT) in deep inspiration breath-hold (DIBH) for mediastinal lymphoma patients, by retrospectively evaluating plan robustness to the clinical target volume (CTV) and organs at risk (OARs) on repeated CT images acquired throughout treatment.  Methods: Sixteen mediastinal lymphoma patients treated with PBS-PT in DIBH were included. Treatment plans (TPs) were robustly optimized on the CTV (7 mm/4.5%). Repeated verification CTs (vCT) were acquired during the treatment course, resulting in 52 images for the entire patient cohort. The CTV and OARs were transferred from the planning CT to the vCTs with deformable image registration and the TPs were recalculated on the vCTs. Target coverage and OAR doses at the vCTs were compared to the nominal plan. Deviation in lung volume was also calculated. The TPs demonstrated high robust target coverage throughout treatment with D98%,CTV deviations within 2% for 14 patients and above the desired requirement of 95% for 49/52 vCTs. However, two patients did not achieve a robust dose to CTV due to poor DIBH reproducibility, with D98%,CTV at 78 and 93% respectively, and replanning was performed for one patient. Adequate OAR sparing was achieved for all patients. Total lung volume variation was below 10% for 39/52 vCTs. PBS PT in DIBH is generally a robust technique for treatment of mediastinal lymphomas. However, closely monitoring the DIBH-reproducibility during treatment is important to avoid underdosing CTV and achieve sufficient dose-sparing of the OARs.

Sections du résumé

PURPOSE/BACKGROUND OBJECTIVE
The aim of this study was to evaluate pencil beam scanning (PBS) proton therapy (PT) in deep inspiration breath-hold (DIBH) for mediastinal lymphoma patients, by retrospectively evaluating plan robustness to the clinical target volume (CTV) and organs at risk (OARs) on repeated CT images acquired throughout treatment.  Methods: Sixteen mediastinal lymphoma patients treated with PBS-PT in DIBH were included. Treatment plans (TPs) were robustly optimized on the CTV (7 mm/4.5%). Repeated verification CTs (vCT) were acquired during the treatment course, resulting in 52 images for the entire patient cohort. The CTV and OARs were transferred from the planning CT to the vCTs with deformable image registration and the TPs were recalculated on the vCTs. Target coverage and OAR doses at the vCTs were compared to the nominal plan. Deviation in lung volume was also calculated.
RESULTS RESULTS
The TPs demonstrated high robust target coverage throughout treatment with D98%,CTV deviations within 2% for 14 patients and above the desired requirement of 95% for 49/52 vCTs. However, two patients did not achieve a robust dose to CTV due to poor DIBH reproducibility, with D98%,CTV at 78 and 93% respectively, and replanning was performed for one patient. Adequate OAR sparing was achieved for all patients. Total lung volume variation was below 10% for 39/52 vCTs.
CONCLUSION CONCLUSIONS
PBS PT in DIBH is generally a robust technique for treatment of mediastinal lymphomas. However, closely monitoring the DIBH-reproducibility during treatment is important to avoid underdosing CTV and achieve sufficient dose-sparing of the OARs.

Identifiants

pubmed: 38415848
doi: 10.2340/1651-226X.2024.23964
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

62-69

Auteurs

Filip Hörberger (F)

Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden. Filip.Horberger@skane.se.

Karin M Andersson (KM)

Department of Medical Physics, The Skandion Clinic, Uppsala, Sweden.

Marika Enmark (M)

Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden; Department of Medical Physics, The Skandion Clinic, Uppsala, Sweden.

Ingrid Kristensen (I)

Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden; Department of Clinical Sciences, Oncology, Lund University, Lund, Sweden.

Anna Flejmer (A)

Department of Medical Physics, The Skandion Clinic, Uppsala, Sweden; Department of Immunology, Genetics and Pathology, Uppsala University, Uppsala, Sweden; Department of Oncology, Uppsala University Hospital, Uppsala, Sweden.

Anneli Edvardsson (A)

Radiation Physics, Department of Hematology, Oncology and Radiation Physics, Skåne University Hospital, Sweden; Medical Radiation Physics, Department of Clinical Sciences Lund, Lund University, Lund, Sweden.

Classifications MeSH