Adjustment for Renal Function Improves the Prognostic Performance of Urinary Thromboxane Metabolites.


Journal

Clinical chemistry
ISSN: 1530-8561
Titre abrégé: Clin Chem
Pays: England
ID NLM: 9421549

Informations de publication

Date de publication:
28 Feb 2024
Historique:
received: 29 07 2023
accepted: 26 12 2023
medline: 28 2 2024
pubmed: 28 2 2024
entrez: 28 2 2024
Statut: aheadofprint

Résumé

Systemic thromboxane A2 generation, assessed by quantifying the concentration of stable thromboxane B2 metabolites (TXB2-M) in the urine adjusted for urinary creatinine, is strongly associated with mortality risk. We sought to define optimal TXB2-M cutpoints for aspirin users and nonusers and determine if adjusting TXB2-M for estimated glomerular filtration rate (eGFR) in addition to urinary creatinine improved mortality risk assessment. Urinary TXB2-M were measured by competitive ELISA in 1363 aspirin users and 1681 nonusers participating in the Framingham Heart Study. Cutpoints were determined for TXB2-M and TXB2-M/eGFR using log-rank statistics and used to assess mortality risk by Cox proportional hazard modeling and restricted mean survival time. Multivariable models were compared using the Akaike Information Criterion (AIC). A cohort of 105 aspirin users with heart failure was used for external validation. Optimized cutpoints of TXB2-M were 1291 and 5609 pg/mg creatinine and of TXB2-M/eGFR were 16.6 and 62.1 filtered prostanoid units (defined as pg·min/creatinine·mL·1.73 m2), for aspirin users and nonusers, respectively. TXB2-M/eGFR cutpoints provided more robust all-cause mortality risk discrimination than TXB2-M cutpoints, with a larger unadjusted hazard ratio (2.88 vs 2.16, AIC P < 0.0001) and greater differences in restricted mean survival time between exposure groups (1.46 vs 1.10 years), findings that were confirmed in the external validation cohort of aspirin users. TXB2-M/eGFR cutpoints also provided better cardiovascular/stroke mortality risk discrimination than TXB2-M cutpoints (unadjusted hazard ratio 3.31 vs 2.13, AIC P < 0.0001). Adjustment for eGFR strengthens the association of urinary TXB2-M with long-term mortality risk irrespective of aspirin use.

Sections du résumé

BACKGROUND BACKGROUND
Systemic thromboxane A2 generation, assessed by quantifying the concentration of stable thromboxane B2 metabolites (TXB2-M) in the urine adjusted for urinary creatinine, is strongly associated with mortality risk. We sought to define optimal TXB2-M cutpoints for aspirin users and nonusers and determine if adjusting TXB2-M for estimated glomerular filtration rate (eGFR) in addition to urinary creatinine improved mortality risk assessment.
METHODS METHODS
Urinary TXB2-M were measured by competitive ELISA in 1363 aspirin users and 1681 nonusers participating in the Framingham Heart Study. Cutpoints were determined for TXB2-M and TXB2-M/eGFR using log-rank statistics and used to assess mortality risk by Cox proportional hazard modeling and restricted mean survival time. Multivariable models were compared using the Akaike Information Criterion (AIC). A cohort of 105 aspirin users with heart failure was used for external validation.
RESULTS RESULTS
Optimized cutpoints of TXB2-M were 1291 and 5609 pg/mg creatinine and of TXB2-M/eGFR were 16.6 and 62.1 filtered prostanoid units (defined as pg·min/creatinine·mL·1.73 m2), for aspirin users and nonusers, respectively. TXB2-M/eGFR cutpoints provided more robust all-cause mortality risk discrimination than TXB2-M cutpoints, with a larger unadjusted hazard ratio (2.88 vs 2.16, AIC P < 0.0001) and greater differences in restricted mean survival time between exposure groups (1.46 vs 1.10 years), findings that were confirmed in the external validation cohort of aspirin users. TXB2-M/eGFR cutpoints also provided better cardiovascular/stroke mortality risk discrimination than TXB2-M cutpoints (unadjusted hazard ratio 3.31 vs 2.13, AIC P < 0.0001).
CONCLUSION CONCLUSIONS
Adjustment for eGFR strengthens the association of urinary TXB2-M with long-term mortality risk irrespective of aspirin use.

Identifiants

pubmed: 38416712
pii: 7615702
doi: 10.1093/clinchem/hvae015
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Informations de copyright

© Association for Diagnostics & Laboratory Medicine 2024. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.

Auteurs

Bruce A Barton (BA)

University of Massachusetts Chan Medical School, Worcester, MA, United States.

Shari S Kronsberg (SS)

University of Massachusetts Chan Medical School, Worcester, MA, United States.

Essa Hariri (E)

University of Massachusetts Chan Medical School, Worcester, MA, United States.
Johns Hopkins School of Medicine, Baltimore, MD, United States.

Ramachandran S Vasan (RS)

Boston University Framingham Heart Study, Boston, MA, United States.
University of Texas School of Public Health in San Antonio, San Antonio, TX, United States.

Grace A Rade (GA)

University of Massachusetts Chan Medical School, Worcester, MA, United States.

Vanessa Xanthakis (V)

Boston University Framingham Heart Study, Boston, MA, United States.

Thomas S Kickler (TS)

Johns Hopkins School of Medicine, Baltimore, MD, United States.

Jeffrey J Rade (JJ)

University of Massachusetts Chan Medical School, Worcester, MA, United States.
Johns Hopkins School of Medicine, Baltimore, MD, United States.

Classifications MeSH