Fluoroscopic images of the sacroiliac joint alone are unable to identify simulated flexion or extension malreduction of the anterior pelvic ring in AO/OTA 61-B2.3 pelvic injuries.
Cadaveric simulation
Pelvic deformity
Pelvic ring injuries
Journal
European journal of orthopaedic surgery & traumatology : orthopedie traumatologie
ISSN: 1432-1068
Titre abrégé: Eur J Orthop Surg Traumatol
Pays: France
ID NLM: 9518037
Informations de publication
Date de publication:
29 Feb 2024
29 Feb 2024
Historique:
received:
01
11
2023
accepted:
18
01
2024
medline:
29
2
2024
pubmed:
29
2
2024
entrez:
29
2
2024
Statut:
aheadofprint
Résumé
Reduction of AO/OTA 61-B2.3 (APC2) pelvic fractures is challenging in the setting of anterior ring comminution. The anterior ring is visually much simpler to evaluate for flexion or extension hemipelvis deformity than the posterior ring, except in the setting of comminution, necessitating some other visual reference to judge hemipelvis reduction. We sought to test whether pelvic inlet and outlet fluoroscopy of the contours of the sacroiliac joint could be used in isolation to judge hemipelvis flexion or extension. Symphyseal and anterior SIJ ligaments were cut (6 cadaveric pelvis). The symphysis was held malreduced to produce one centimeter flexion and extension deformity: 1 cm was selected to mimic a maximum clinical scenario. The SIJ was assessed using inlet and outlet fluoroscopy. The scaled width of the SIJ was assessed at the joint apertures and midjoint on both inlet and outlet views. Joint widths in flexion and extension were compared against joint widths measured on the reduced SIJ using paired t-tests. There was no statistical difference in the superior (p = 0.227, 0.675), middle (p = 0.203, 0.693), and inferior (p = 0.232, 0.961) SIJ widths between hemipelvis flexion or extension models against reduced SIJ on outlet views. There was no statistical difference in the anterior (p = 0.731, 0.662), middle (p = 0.257, 0.655), and posterior (p = 0.657, 0.363) SIJ widths between flexion or extension models against reduced SIJ on inlet views. Inspection of SIJ width on inlet and outlet fluoroscopy cannot detect up to one centimeter of hemipelvis flexion or extension malreduction in the setting of AO/OTA 61-B2.3 (APC2) pelvic fractures with complex anterior injuries.
Identifiants
pubmed: 38421492
doi: 10.1007/s00590-024-03841-w
pii: 10.1007/s00590-024-03841-w
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
© 2024. The Author(s), under exclusive licence to Springer-Verlag France SAS, part of Springer Nature.
Références
Lindsay A, Tornetta P, Diwan A, Templeman D (2016) Is closed reduction and percutaneous fixation of unstable posterior ring injuries as accurate as open reduction and internal fixation? J Orthop Trauma 30:29–33. https://doi.org/10.1097/BOT.0000000000000418
doi: 10.1097/BOT.0000000000000418
pubmed: 26270459
Tornetta P, Matta JM (1996) Outcome of operatively treated unstable posterior pelvic ring disruptions. Clin Orthop 329:186–193
doi: 10.1097/00003086-199608000-00022
Matta JM, Saucedo T (1989) Internal fixation of pelvic ring fractures. Clin Orthop. https://doi.org/10.1097/00003086-198905000-00009
doi: 10.1097/00003086-198905000-00009
pubmed: 2706863
Templeman D, Goulet J, Duwelius PJ et al (1996) Internal fixation of displaced fractures of the sacrum. Clin Orthop 329:180–185
doi: 10.1097/00003086-199608000-00021
Verbeek DO, Routt ML (2018) High-energy pelvic ring disruptions with complete posterior instability: contemporary reduction and fixation strategies. J Bone Jt Surg 100:1704–1712. https://doi.org/10.2106/JBJS.17.01289
doi: 10.2106/JBJS.17.01289
Dujardin FH, Hossenbaccus M, Duparc F et al (1998) Long-term functional prognosis of posterior injuries in high-energy pelvic disruption. J Orthop Trauma 12:145
doi: 10.1097/00005131-199803000-00001
pubmed: 9553853
Letournel E (1981) Surgical fixation of displaced pelvic fractures and dislocations of the symphysis pubis (excluding acetabular fractures) (author’s transl). Rev Chir Orthop Reparatrice Appar Mot 67:771–782
pubmed: 6211739
McLaren AC, Rorabeck CH, Halpenny J (1990) Long-term pain and disability in relation to residual deformity after displaced pelvic ring fractures. Can J Surg J Can Chir 33:492–494
Majeed SA (1990) External fixation of the injured pelvis. The functional outcome. J Bone Joint Surg Br 72:612–614
doi: 10.1302/0301-620X.72B4.2380212
pubmed: 2380212
Semba RT, Yasukawa K, Gustilo RB (1983) Critical analysis of results of 53 Malgaigne fractures of the pelvis. J Trauma 23:535–537
doi: 10.1097/00005373-198306000-00016
pubmed: 6864845
Tile M (1988) Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br 70:1–12
doi: 10.1302/0301-620X.70B1.3276697
pubmed: 3276697
Slätis P, Huittinen VM (1972) Double vertical fractures of the pelvis. A report on 163 patients. Acta Chir Scand 138:799–807
pubmed: 4641153
Simpson LA, Waddell JP, Leighton RK et al (1987) Anterior approach and stabilization of the disrupted sacroiliac joint. J Trauma 27:1332–1339
doi: 10.1097/00005373-198712000-00003
pubmed: 3694724
Gardner MJ, Routt MC Jr (2011) Transiliac–transsacral screws for posterior pelvic stabilization. J Orthop Trauma 25:378–384
doi: 10.1097/BOT.0b013e3181e47fad
pubmed: 21577075
Routt ML, Kregor PJ, Simonian PT, Mayo KA (1995) Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma 9:207–214
doi: 10.1097/00005131-199506000-00005
pubmed: 7623172
Giannoudis PV, Tzioupis CC, Pape H-C, Roberts CS (2007) Percutaneous fixation of the pelvic ring: an update. J Bone Joint Surg Br 89:145–154. https://doi.org/10.1302/0301-620X.89B2.18551
doi: 10.1302/0301-620X.89B2.18551
pubmed: 17322425
Avilucea FR, Whiting PS, Mir H (2016) Posterior fixation of APC-2 pelvic ring injuries decreases rates of anterior plate failure and malunion. J Bone Jt Surg 98:944–951. https://doi.org/10.2106/JBJS.15.00723
doi: 10.2106/JBJS.15.00723
Avilucea FR, Archdeacon MT, Collinge CA et al (2018) Fixation strategy using sequential intraoperative examination under anesthesia for unstable lateral compression pelvic ring injuries reliably predicts union with minimal displacement. J Bone Jt Surg 100:1503–1508. https://doi.org/10.2106/JBJS.17.01650
doi: 10.2106/JBJS.17.01650
Takeba J, Umakoshi K, Kikuchi S et al (2018) Accuracy of screw fixation using the O-arm
doi: 10.1007/s00590-017-2075-9
Ghisla S, Napoli F, Lehoczky G et al (2018) Posterior pelvic ring fractures: Intraoperative 3D-CT guided navigation for accurate positioning of sacro-iliac screws. Orthop Traumatol Surg Res 104:1063–1067. https://doi.org/10.1016/j.otsr.2018.07.006
doi: 10.1016/j.otsr.2018.07.006
pubmed: 30081217