Quercetin nanoparticles decorated on Arabic gum and polyvinyl alcohol composite as a film sensor for fluorescence detection of meropenem.
Arabic gum
Film sensor
Fluorimetric
Meropenem
Polyvinyl alcohol
Quercetin nanoparticles
Journal
Talanta
ISSN: 1873-3573
Titre abrégé: Talanta
Pays: Netherlands
ID NLM: 2984816R
Informations de publication
Date de publication:
15 May 2024
15 May 2024
Historique:
received:
03
11
2023
revised:
07
02
2024
accepted:
12
02
2024
medline:
18
3
2024
pubmed:
2
3
2024
entrez:
1
3
2024
Statut:
ppublish
Résumé
Moving towards green chemistry to minimize the diverse effect of chemicals on human health and environment has become a great issue in chemistry. On the other hand, determination of pharmaceuticals is an important issue for both human health and environment. In this regard two natural and benign compounds such as quercetin a polyphenolic flavonoid and Arabic Gum (AG) a polysaccharide were used to construct a sensor for meropenem. Herein, a new method was established for the synthesis of AG and polyvinyl alcohol (PVA) composite decorated by quercetin nanoparticles (QUENPs) as a fluorimetric film sensor to measure meropenem. In order to embed QUENPs in the polymer composite substrate, first QUENPs were synthesized and then added to the prepared composite solution under optimal conditions. The characteristics of AG and PVA composite (AG-PVA) and AG-PVA composite decorated by QUENPs films (QUENPs-AG-PVA), before and after the addition of meropenem was studied by TEM, FT-IR and EDX-Mapping. The developed film sensor was placed in a holder made with 3D printer. The difference in the fluorescence intensity of the fabricated film before and after the addition of meropenem was taken as the signal for measuring meropenem. The effect of different parameters on the fabrication of film fluorimetric sensor such as the concentration of polymer solutions, the volume of QUENPs and the volume of glycerol were investigated. Factors affecting the measurement of meropenem such as pH, type of buffer, volume of meropenem solution added on the sensor and time were also investigated. Under the obtained optimum conditions, the calibration graph was linear in the concentration range of 50-800 ng mL
Identifiants
pubmed: 38428130
pii: S0039-9140(24)00168-1
doi: 10.1016/j.talanta.2024.125789
pii:
doi:
Substances chimiques
Polyvinyl Alcohol
9002-89-5
Meropenem
FV9J3JU8B1
Quercetin
9IKM0I5T1E
Polymers
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
125789Informations de copyright
Copyright © 2024 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.