Rotational thrombectomy versus balloon maceration in dialysis access salvage.

Hemodialysis arteriovenous fistula arteriovenous graft balloon maceration rotational thrombectomy

Journal

The journal of vascular access
ISSN: 1724-6032
Titre abrégé: J Vasc Access
Pays: United States
ID NLM: 100940729

Informations de publication

Date de publication:
04 Mar 2024
Historique:
medline: 4 3 2024
pubmed: 4 3 2024
entrez: 4 3 2024
Statut: aheadofprint

Résumé

Although end stage renal disease patients who undergo hemodialysis frequently experience dialysis-associated thrombotic complications, there remains a paucity of literature comparing the efficacy of different endovascular salvage techniques for grafts and fistulas. This study aims to compare primary patency in dialysis access following salvage mechanical thrombolysis/thrombectomy with a rotational thrombolysis device versus balloon maceration. Using a database of patient records at a tertiary medical center, all patients who underwent rotational thrombectomy with the Cleaner XT™ Rotational Thrombectomy System for endovascular salvage of arteriovenous fistula or arteriovenous graft from August 2016 to July 2022 were included in the population. Fourteen patients who underwent balloon maceration for endovascular salvage were matched to the patients in the rotational thrombectomy group based on date of procedure. The primary patency of the fistula or graft for the two groups was measured. A total of 13 patients who underwent dialysis access salvage with rotational thrombectomy (10 grafts, 3 fistulas) were matched with 14 patients who underwent balloon maceration for dialysis access salvage (10 grafts, 4 fistulas). Six patients in both groups required additional graft access salvage (46% rotational thrombectomy; 43% balloon maceration). The median time to next dialysis salvage was 51 days for rotational thrombectomy and 43.5 days for balloon maceration (W + 9, critical value 1; compatible with statistically significant difference). Endovascular access salvage by rotational thrombectomy may provide longer primary patency compared to salvage by balloon maceration. However, a longer follow-up prospective study of a larger study population is necessary to clarify the safety and efficacy of rotational thrombectomy using the Cleaner XT™ device.

Sections du résumé

BACKGROUND UNASSIGNED
Although end stage renal disease patients who undergo hemodialysis frequently experience dialysis-associated thrombotic complications, there remains a paucity of literature comparing the efficacy of different endovascular salvage techniques for grafts and fistulas. This study aims to compare primary patency in dialysis access following salvage mechanical thrombolysis/thrombectomy with a rotational thrombolysis device versus balloon maceration.
METHODS UNASSIGNED
Using a database of patient records at a tertiary medical center, all patients who underwent rotational thrombectomy with the Cleaner XT™ Rotational Thrombectomy System for endovascular salvage of arteriovenous fistula or arteriovenous graft from August 2016 to July 2022 were included in the population. Fourteen patients who underwent balloon maceration for endovascular salvage were matched to the patients in the rotational thrombectomy group based on date of procedure. The primary patency of the fistula or graft for the two groups was measured.
RESULTS UNASSIGNED
A total of 13 patients who underwent dialysis access salvage with rotational thrombectomy (10 grafts, 3 fistulas) were matched with 14 patients who underwent balloon maceration for dialysis access salvage (10 grafts, 4 fistulas). Six patients in both groups required additional graft access salvage (46% rotational thrombectomy; 43% balloon maceration). The median time to next dialysis salvage was 51 days for rotational thrombectomy and 43.5 days for balloon maceration (W + 9, critical value 1; compatible with statistically significant difference).
CONCLUSION UNASSIGNED
Endovascular access salvage by rotational thrombectomy may provide longer primary patency compared to salvage by balloon maceration. However, a longer follow-up prospective study of a larger study population is necessary to clarify the safety and efficacy of rotational thrombectomy using the Cleaner XT™ device.

Identifiants

pubmed: 38436294
doi: 10.1177/11297298241234990
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

11297298241234990

Déclaration de conflit d'intérêts

Declaration of conflicting interestsThe author(s) declared no potential conflicts of interest with respect to the research, authorship, and/or publication of this article.

Auteurs

Jee Hyuk Byun (JH)

Department of Interventional Radiology, University of Alabama Birmingham, Birmingham, AL, USA.
CHA Bundang Medical Center, CHA University, Seongnam, Gyeonggi-do, Republic of Korea.

Andrew Rennie (A)

School of Medicine, Florida State University, Tallahassee, FL, USA.

Junjian Huang (J)

Department of Interventional Radiology, University of Alabama Birmingham, Birmingham, AL, USA.

Junaid Raja (J)

Department of Interventional Radiology, University of Alabama Birmingham, Birmingham, AL, USA.

Classifications MeSH