Effects of tricuspid transcatheter edge-to-edge repair on tricuspid annulus diameter - Data from the TriValve registry.
Transcatheter edge-to-edge repair
Transcatheter tricuspid valve interventions
Tricuspid annulus
Tricuspid regurgitation
Journal
International journal of cardiology
ISSN: 1874-1754
Titre abrégé: Int J Cardiol
Pays: Netherlands
ID NLM: 8200291
Informations de publication
Date de publication:
02 Mar 2024
02 Mar 2024
Historique:
received:
17
11
2023
revised:
13
01
2024
accepted:
01
03
2024
medline:
5
3
2024
pubmed:
5
3
2024
entrez:
4
3
2024
Statut:
aheadofprint
Résumé
T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.
Identifiants
pubmed: 38437953
pii: S0167-5273(24)00452-2
doi: 10.1016/j.ijcard.2024.131934
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
131934Informations de copyright
Copyright © 2024 Elsevier B.V. All rights reserved.