Résumé

Prehospital identification of futile resuscitation efforts (defined as a predicted probability of survival lower than 1%) for out-of-hospital cardiac arrest (OHCA) may reduce unnecessary transport. Reliable prediction variables for OHCA 'termination of resuscitation' (TOR) rules are needed to guide treatment decisions. The Universal TOR rule uses only three variables (Absence of Prehospital ROSC, Event not witnessed by EMS and no shock delivered on the scene) has been externally validated and is used by many EMS systems. Deep learning, an artificial intelligence (AI) platform is an attractive model to guide the development of TOR rule for OHCA. The purpose of this study was to assess the feasibility of developing an AI-TOR rule for neurologically favorable outcomes using general purpose AI and compare its performance to the Universal TOR rule. We identified OHCA cases of presumed cardiac etiology who were 18 years of age or older from 2016 to 2019 in the All-Japan Utstein Registry. We divided the dataset into 2 parts, the first half (2016- 2017) was used as a training dataset for rule development and second half (2018- 2019) for validation. The AI software (Prediction One®) created the model using the training dataset with internal cross-validation. It also evaluated the prediction accuracy and displayed the ranking of influencing variables. We performed validation using the second half cases and calculated the prediction model AUC. The top four of the 11 variables identified in the model were then selected as prognostic factors to be used in an AI-TOR rule, and sensitivity, specificity, positive predictive value, and negative predictive value were calculated from validation cohort. This was then compared to the performance of the Universal TOR rule using same dataset. There were 504,561 OHCA cases, 18 years of age or older, 302,799 cases were presumed cardiac origin. Of these, 149,425 cases were used for the training dataset and 153,374 cases for the validation dataset. The model developed by AI using 11 variables had an AUC of 0.969, and its AUC for the validation dataset was 0.965. The top four influencing variables for neurologically favorable outcome were Prehospital ROSC, witnessed by EMS, Age (68 years old and younger) and nonasystole. The AUC calculated using the 4 variables for the AI-TOR rule was 0.953, and its AUC for the validation dataset was 0.952 (95%CI 0.949 -0.954). Of 80,198 patients in the validation cohort that satisfied all four criteria for the AI-TOR rule, 58 (0.07%) had a neurologically favorable one-month survival. The specificity of AI-TOR rule was 0.990, and the PPV was 0.999 for predicting lack of neurologically favorable survival, both the specificity and PPV were higher than that achieved with the universal TOR (0.959, 0.998). The accuracy of prediction models using AI software to determine outcomes in OHCA was excellent and the AI-TOR rule's variables from prediction model performed better than the Universal TOR rule. External validation of our findings as well as further research into the utility of using AI platforms for TOR prediction in clinical practice is needed.

Sections du résumé

BACKGROUND BACKGROUND
Prehospital identification of futile resuscitation efforts (defined as a predicted probability of survival lower than 1%) for out-of-hospital cardiac arrest (OHCA) may reduce unnecessary transport. Reliable prediction variables for OHCA 'termination of resuscitation' (TOR) rules are needed to guide treatment decisions. The Universal TOR rule uses only three variables (Absence of Prehospital ROSC, Event not witnessed by EMS and no shock delivered on the scene) has been externally validated and is used by many EMS systems. Deep learning, an artificial intelligence (AI) platform is an attractive model to guide the development of TOR rule for OHCA. The purpose of this study was to assess the feasibility of developing an AI-TOR rule for neurologically favorable outcomes using general purpose AI and compare its performance to the Universal TOR rule.
METHODS METHODS
We identified OHCA cases of presumed cardiac etiology who were 18 years of age or older from 2016 to 2019 in the All-Japan Utstein Registry. We divided the dataset into 2 parts, the first half (2016- 2017) was used as a training dataset for rule development and second half (2018- 2019) for validation. The AI software (Prediction One®) created the model using the training dataset with internal cross-validation. It also evaluated the prediction accuracy and displayed the ranking of influencing variables. We performed validation using the second half cases and calculated the prediction model AUC. The top four of the 11 variables identified in the model were then selected as prognostic factors to be used in an AI-TOR rule, and sensitivity, specificity, positive predictive value, and negative predictive value were calculated from validation cohort. This was then compared to the performance of the Universal TOR rule using same dataset.
RESULTS RESULTS
There were 504,561 OHCA cases, 18 years of age or older, 302,799 cases were presumed cardiac origin. Of these, 149,425 cases were used for the training dataset and 153,374 cases for the validation dataset. The model developed by AI using 11 variables had an AUC of 0.969, and its AUC for the validation dataset was 0.965. The top four influencing variables for neurologically favorable outcome were Prehospital ROSC, witnessed by EMS, Age (68 years old and younger) and nonasystole. The AUC calculated using the 4 variables for the AI-TOR rule was 0.953, and its AUC for the validation dataset was 0.952 (95%CI 0.949 -0.954). Of 80,198 patients in the validation cohort that satisfied all four criteria for the AI-TOR rule, 58 (0.07%) had a neurologically favorable one-month survival. The specificity of AI-TOR rule was 0.990, and the PPV was 0.999 for predicting lack of neurologically favorable survival, both the specificity and PPV were higher than that achieved with the universal TOR (0.959, 0.998).
CONCLUSIONS CONCLUSIONS
The accuracy of prediction models using AI software to determine outcomes in OHCA was excellent and the AI-TOR rule's variables from prediction model performed better than the Universal TOR rule. External validation of our findings as well as further research into the utility of using AI platforms for TOR prediction in clinical practice is needed.

Identifiants

pubmed: 38452995
pii: S0300-9572(24)00058-3
doi: 10.1016/j.resuscitation.2024.110165
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

110165

Informations de copyright

Copyright © 2024 Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Kentaro Kajino (K)

Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan. Electronic address: kajihanapu@yahoo.co.jp.

Mohamud R Daya (MR)

Department of Emergency Medicine, Oregon Health & Science University, Portland, OR, USA.

Atsunori Onoe (A)

Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan.

Fumiko Nakamura (F)

Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan.

Mari Nakajima (M)

Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan.

Kazuhito Sakuramoto (K)

Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan.

Yasuyuki Marcus Eng Hock Ong (Y)

Department of Emergency Medicine, Singapore General Hospital, Singapore; Health Services and Systems Research, Duke-NUS Medical School, Singapore.
Department of Emergency and Critical Care Medicine, Kansai Medical University, Hirakata, Osaka, Japan.

Classifications MeSH