Development and validation of a prehospital termination of resuscitation (TOR) rule for Out - Of Hospital Cardiac Arrest (OHCA) Cases using general purpose artificial intelligence (AI).
Journal
Resuscitation
ISSN: 1873-1570
Titre abrégé: Resuscitation
Pays: Ireland
ID NLM: 0332173
Informations de publication
Date de publication:
05 Mar 2024
05 Mar 2024
Historique:
received:
02
01
2024
revised:
27
02
2024
accepted:
28
02
2024
medline:
8
3
2024
pubmed:
8
3
2024
entrez:
7
3
2024
Statut:
aheadofprint
Résumé
Prehospital identification of futile resuscitation efforts (defined as a predicted probability of survival lower than 1%) for out-of-hospital cardiac arrest (OHCA) may reduce unnecessary transport. Reliable prediction variables for OHCA 'termination of resuscitation' (TOR) rules are needed to guide treatment decisions. The Universal TOR rule uses only three variables (Absence of Prehospital ROSC, Event not witnessed by EMS and no shock delivered on the scene) has been externally validated and is used by many EMS systems. Deep learning, an artificial intelligence (AI) platform is an attractive model to guide the development of TOR rule for OHCA. The purpose of this study was to assess the feasibility of developing an AI-TOR rule for neurologically favorable outcomes using general purpose AI and compare its performance to the Universal TOR rule. We identified OHCA cases of presumed cardiac etiology who were 18 years of age or older from 2016 to 2019 in the All-Japan Utstein Registry. We divided the dataset into 2 parts, the first half (2016- 2017) was used as a training dataset for rule development and second half (2018- 2019) for validation. The AI software (Prediction One®) created the model using the training dataset with internal cross-validation. It also evaluated the prediction accuracy and displayed the ranking of influencing variables. We performed validation using the second half cases and calculated the prediction model AUC. The top four of the 11 variables identified in the model were then selected as prognostic factors to be used in an AI-TOR rule, and sensitivity, specificity, positive predictive value, and negative predictive value were calculated from validation cohort. This was then compared to the performance of the Universal TOR rule using same dataset. There were 504,561 OHCA cases, 18 years of age or older, 302,799 cases were presumed cardiac origin. Of these, 149,425 cases were used for the training dataset and 153,374 cases for the validation dataset. The model developed by AI using 11 variables had an AUC of 0.969, and its AUC for the validation dataset was 0.965. The top four influencing variables for neurologically favorable outcome were Prehospital ROSC, witnessed by EMS, Age (68 years old and younger) and nonasystole. The AUC calculated using the 4 variables for the AI-TOR rule was 0.953, and its AUC for the validation dataset was 0.952 (95%CI 0.949 -0.954). Of 80,198 patients in the validation cohort that satisfied all four criteria for the AI-TOR rule, 58 (0.07%) had a neurologically favorable one-month survival. The specificity of AI-TOR rule was 0.990, and the PPV was 0.999 for predicting lack of neurologically favorable survival, both the specificity and PPV were higher than that achieved with the universal TOR (0.959, 0.998). The accuracy of prediction models using AI software to determine outcomes in OHCA was excellent and the AI-TOR rule's variables from prediction model performed better than the Universal TOR rule. External validation of our findings as well as further research into the utility of using AI platforms for TOR prediction in clinical practice is needed.
Sections du résumé
BACKGROUND
BACKGROUND
Prehospital identification of futile resuscitation efforts (defined as a predicted probability of survival lower than 1%) for out-of-hospital cardiac arrest (OHCA) may reduce unnecessary transport. Reliable prediction variables for OHCA 'termination of resuscitation' (TOR) rules are needed to guide treatment decisions. The Universal TOR rule uses only three variables (Absence of Prehospital ROSC, Event not witnessed by EMS and no shock delivered on the scene) has been externally validated and is used by many EMS systems. Deep learning, an artificial intelligence (AI) platform is an attractive model to guide the development of TOR rule for OHCA. The purpose of this study was to assess the feasibility of developing an AI-TOR rule for neurologically favorable outcomes using general purpose AI and compare its performance to the Universal TOR rule.
METHODS
METHODS
We identified OHCA cases of presumed cardiac etiology who were 18 years of age or older from 2016 to 2019 in the All-Japan Utstein Registry. We divided the dataset into 2 parts, the first half (2016- 2017) was used as a training dataset for rule development and second half (2018- 2019) for validation. The AI software (Prediction One®) created the model using the training dataset with internal cross-validation. It also evaluated the prediction accuracy and displayed the ranking of influencing variables. We performed validation using the second half cases and calculated the prediction model AUC. The top four of the 11 variables identified in the model were then selected as prognostic factors to be used in an AI-TOR rule, and sensitivity, specificity, positive predictive value, and negative predictive value were calculated from validation cohort. This was then compared to the performance of the Universal TOR rule using same dataset.
RESULTS
RESULTS
There were 504,561 OHCA cases, 18 years of age or older, 302,799 cases were presumed cardiac origin. Of these, 149,425 cases were used for the training dataset and 153,374 cases for the validation dataset. The model developed by AI using 11 variables had an AUC of 0.969, and its AUC for the validation dataset was 0.965. The top four influencing variables for neurologically favorable outcome were Prehospital ROSC, witnessed by EMS, Age (68 years old and younger) and nonasystole. The AUC calculated using the 4 variables for the AI-TOR rule was 0.953, and its AUC for the validation dataset was 0.952 (95%CI 0.949 -0.954). Of 80,198 patients in the validation cohort that satisfied all four criteria for the AI-TOR rule, 58 (0.07%) had a neurologically favorable one-month survival. The specificity of AI-TOR rule was 0.990, and the PPV was 0.999 for predicting lack of neurologically favorable survival, both the specificity and PPV were higher than that achieved with the universal TOR (0.959, 0.998).
CONCLUSIONS
CONCLUSIONS
The accuracy of prediction models using AI software to determine outcomes in OHCA was excellent and the AI-TOR rule's variables from prediction model performed better than the Universal TOR rule. External validation of our findings as well as further research into the utility of using AI platforms for TOR prediction in clinical practice is needed.
Identifiants
pubmed: 38452995
pii: S0300-9572(24)00058-3
doi: 10.1016/j.resuscitation.2024.110165
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
110165Informations de copyright
Copyright © 2024 Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.