Influence of acclimatization time on parameters of barometric whole-body plethysmography in healthy adult cats.
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2024
2024
Historique:
received:
02
10
2023
accepted:
06
02
2024
medline:
12
3
2024
pubmed:
12
3
2024
entrez:
12
3
2024
Statut:
epublish
Résumé
Pulmonary function testing by barometric whole-body plethysmography (BWBP) is a long-established and well-accepted, non-invasive investigative procedure in cats. To evaluate, if different acclimatization times influence the measurement parameters of BWBP in healthy adult cats. 48 healthy adult cats. In the prospective observational study, healthy cats were placed in a measuring chamber and BWBP was performed over 30 minutes. Parameters obtained during the three measurement units of 10 minutes each (T1, T2 and T3) were compared. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) over the three time periods. From T1-T2, the parameters minute volume per body weight (p<0.001), peak inspiratory flow per body weight (p<0.001), peak expiratory flow per body weight (p = 0.002), pause (p = 0.03), enhanced pause (p = 0.03) and quotient of peak expiratory flow divided by expiratory flow at end expiratory volume plus 50% tidal volume (p = 0.03) changed significantly. From the time interval T2-T3, only respiratory rate (p = 0.02), inspiratory time (p = 0.02), expiratory time (p = 0.04), and relaxation time (p = 0.01) changed significantly. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) between T1 and T3. Age had a significant influence on all parameters except for peak expiratory flow per body weight and peak inspiratory flow per body weight. The parameters were not influenced by sex. All measurement parameters except tidal volume per body weight were significantly affected by acclimatization time. Controlling for age and sex, there was still a significant influence of acclimatization time on all parameters except for tidal volume per body weight. Standardization of the acclimatization time for future studies would be appropriate in order to maintain comparability.
Sections du résumé
BACKGROUND
BACKGROUND
Pulmonary function testing by barometric whole-body plethysmography (BWBP) is a long-established and well-accepted, non-invasive investigative procedure in cats.
HYPOTHESIS/OBJECTIVES
OBJECTIVE
To evaluate, if different acclimatization times influence the measurement parameters of BWBP in healthy adult cats.
ANIMALS
METHODS
48 healthy adult cats.
METHODS
METHODS
In the prospective observational study, healthy cats were placed in a measuring chamber and BWBP was performed over 30 minutes. Parameters obtained during the three measurement units of 10 minutes each (T1, T2 and T3) were compared.
RESULTS
RESULTS
All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) over the three time periods. From T1-T2, the parameters minute volume per body weight (p<0.001), peak inspiratory flow per body weight (p<0.001), peak expiratory flow per body weight (p = 0.002), pause (p = 0.03), enhanced pause (p = 0.03) and quotient of peak expiratory flow divided by expiratory flow at end expiratory volume plus 50% tidal volume (p = 0.03) changed significantly. From the time interval T2-T3, only respiratory rate (p = 0.02), inspiratory time (p = 0.02), expiratory time (p = 0.04), and relaxation time (p = 0.01) changed significantly. All measurement parameters except for tidal volume per body weight changed significantly (p<0.05) between T1 and T3. Age had a significant influence on all parameters except for peak expiratory flow per body weight and peak inspiratory flow per body weight. The parameters were not influenced by sex.
CONCLUSION AND CLINICAL IMPORTANCE
CONCLUSIONS
All measurement parameters except tidal volume per body weight were significantly affected by acclimatization time. Controlling for age and sex, there was still a significant influence of acclimatization time on all parameters except for tidal volume per body weight. Standardization of the acclimatization time for future studies would be appropriate in order to maintain comparability.
Identifiants
pubmed: 38470892
doi: 10.1371/journal.pone.0299252
pii: PONE-D-23-31940
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0299252Informations de copyright
Copyright: © 2024 Benz et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.