Deep Convolutional Neural Networks Provide Motion Grading for High-Resolution Peripheral Quantitative Computed Tomography of the Scaphoid.

artifacts artificial intelligence convolutional neural networks deep learning image quality motion grading

Journal

Diagnostics (Basel, Switzerland)
ISSN: 2075-4418
Titre abrégé: Diagnostics (Basel)
Pays: Switzerland
ID NLM: 101658402

Informations de publication

Date de publication:
06 Mar 2024
Historique:
received: 05 01 2024
revised: 20 02 2024
accepted: 29 02 2024
medline: 13 3 2024
pubmed: 13 3 2024
entrez: 13 3 2024
Statut: epublish

Résumé

In vivo high-resolution peripheral quantitative computed tomography (HR-pQCT) studies on bone characteristics are limited, partly due to the lack of standardized and objective techniques to describe motion artifacts responsible for lower-quality images. This study investigates the ability of such deep-learning techniques to assess image quality in HR-pQCT datasets of human scaphoids. In total, 1451 stacks of 482 scaphoid images from 53 patients, each with up to six follow-ups within one year, and each with one non-displaced fractured and one contralateral intact scaphoid, were independently graded by three observers using a visual grading scale for motion artifacts. A 3D-CNN was used to assess image quality. The accuracy of the 3D-CNN to assess the image quality compared to the mean results of three skilled operators was between 92% and 96%. The 3D-CNN classifier reached an ROC-AUC score of 0.94. The average assessment time for one scaphoid was 2.5 s. This study demonstrates that a deep-learning approach for rating radiological image quality provides objective assessments of motion grading for the scaphoid with a high accuracy and a short assessment time. In the future, such a 3D-CNN approach can be used as a resource-saving and cost-effective tool to classify the image quality of HR-pQCT datasets in a reliable, reproducible and objective way.

Identifiants

pubmed: 38473040
pii: diagnostics14050568
doi: 10.3390/diagnostics14050568
pii:
doi:

Types de publication

Journal Article

Langues

eng

Subventions

Organisme : Johnson & Johnson Medical Products GmbH
ID : GMAFS20353

Auteurs

Stefan Benedikt (S)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Philipp Zelger (P)

Department of Otorhinolaryngology, Hearing, Speech & Voice Disorders, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Lukas Horling (L)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Kerstin Stock (K)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Johannes Pallua (J)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Michael Schirmer (M)

Medical University of Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.
Office Dr. Schirmer, 6060 Hall, Austria.

Gerald Degenhart (G)

Department of Radiology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Alexander Ruzicka (A)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Rohit Arora (R)

Department of Orthopedics and Traumatology, University Hospital Innsbruck, Anichstraße 35, 6020 Innsbruck, Austria.

Classifications MeSH