A new approach to a powered knee prosthesis: Layering powered assistance onto strictly passive prosthesis behavior.
Biomechatronics
Control
Design
Human-robot interaction
Prosthetics
Journal
Wearable technologies
ISSN: 2631-7176
Titre abrégé: Wearable Technol
Pays: England
ID NLM: 9918230402406676
Informations de publication
Date de publication:
2023
2023
Historique:
received:
31
07
2022
revised:
21
04
2023
accepted:
27
04
2023
medline:
15
3
2024
pubmed:
15
3
2024
entrez:
15
3
2024
Statut:
epublish
Résumé
This article describes a novel approach to the control of a powered knee prosthesis where the control system provides passive behavior for most activities and then provides powered assistance only for those activities that require them. The control approach presented here is based on the categorization of knee joint function during activities into four behaviors: resistive stance behavior, active stance behavior, ballistic swing, and non-ballistic swing. The approach is further premised on the assumption that healthy non-perturbed swing-phase is characterized by a ballistic swing motion, and therefore, a replacement of that function should be similarly ballistic. The control system utilizes a six-state finite-state machine, where each state provides different constitutive behaviors (concomitant with the four aforementioned knee behaviors) which are appropriate for a range of activities. Transitions between states and torque control within states is controlled by user motion, such that the control system provides, to the extent possible, knee torque behavior as a reaction to user motion, including for powered behaviors. The control system is demonstrated on a novel device that provides a sufficiently low impedance to enable a strictly passive ballistic swing-phase, while also providing sufficiently high torque to offer powered stance-phase knee-extension during activities such as step-over stair ascent. Experiments employing the knee and control system on an individual with transfemoral amputation are presented that compare the functionality of the power-supplemented nominally passive system with that of a conventional passive microprocessor-controlled knee prosthesis.
Identifiants
pubmed: 38487769
doi: 10.1017/wtc.2023.14
pii: S2631717623000142
pmc: PMC10936382
doi:
Types de publication
Journal Article
Langues
eng
Pagination
e21Informations de copyright
© The Author(s) 2023.
Déclaration de conflit d'intérêts
The authors declare no competing interests exist.