Congenital Heart Defects in Pregnancies Conceived by Assisted Reproductive Technology: Comparing Functional and Structural Defects.
assisted reproductive technologies
birth defects
congenital
fetal echocardiography
heart defects
in vitro fertilization (ivf)
ovulation induction
Journal
Cureus
ISSN: 2168-8184
Titre abrégé: Cureus
Pays: United States
ID NLM: 101596737
Informations de publication
Date de publication:
Feb 2024
Feb 2024
Historique:
accepted:
23
02
2024
medline:
26
3
2024
pubmed:
26
3
2024
entrez:
26
3
2024
Statut:
epublish
Résumé
Introduction Congenital heart defects (CHD) are one of the most common congenital anomalies, and their association with assisted reproductive technology (ART) is controversial in different populations. The purpose of this study was to evaluate this association and to provide information about the necessity of specialized echocardiography during pregnancy with ART. Methods This retrospective study was performed on all pregnancies conceived by ART and referred for fetal echocardiography to the Rasoul Akram and Akbar Abadi hospitals in Tehran, Iran. A total of 109 patients were enrolled in the study (56 in the ART group and 53 in the non-ART). Two-dimensional and color Doppler echocardiography were performed on all patients to identify heart problems and anomalies and medical records of the patients were reviewed. The outcome was considered the presence of functional and structural heart defects on echocardiography. Results The study groups were similar in terms of maternal age and GA. The ART group consisted of 31 singletons (55%) and 25 multiples (45%). All pregnancies in the non-ART group were singletons. Following in vitro fertilization (33%), ovulation induction (25%) was the next most used method. The findings of echocardiography were one atrial septal defect (ASD) in ART and one in non-ART, six ventricular septal defects (VSD) in ART and three in non-ART, and one ASD and VSD in the ART group. These structural abnormalities showed no difference in the two groups (P value = 0.58). There was no significant difference in rhythm between the two groups (P = 0.51). Echocardiographic indices of both groups did not differ statistically except in the TR-PG index (P value = 0.02). Conclusions The structural defects of the two groups were not different, and no heart dysfunction was observed in ART fetuses. There was no association between ART and CHD in our study. We concluded that echocardiography by pediatric cardiologists is not necessary for these fetuses.
Identifiants
pubmed: 38529454
doi: 10.7759/cureus.54810
pmc: PMC10961672
doi:
Types de publication
Journal Article
Langues
eng
Pagination
e54810Informations de copyright
Copyright © 2024, Rasouli et al.
Déclaration de conflit d'intérêts
The authors have declared that no competing interests exist.