Impact of AI-Based Post-Processing on Image Quality of Non-Contrast Computed Tomography of the Chest and Abdomen.

COVID-19 abdomen chest computed tomography deep learning image quality image reconstruction urolithiasis

Journal

Diagnostics (Basel, Switzerland)
ISSN: 2075-4418
Titre abrégé: Diagnostics (Basel)
Pays: Switzerland
ID NLM: 101658402

Informations de publication

Date de publication:
13 Mar 2024
Historique:
received: 16 02 2024
revised: 08 03 2024
accepted: 09 03 2024
medline: 27 3 2024
pubmed: 27 3 2024
entrez: 27 3 2024
Statut: epublish

Résumé

Non-contrast computed tomography (CT) is commonly used for the evaluation of various pathologies including pulmonary infections or urolithiasis but, especially in low-dose protocols, image quality is reduced. To improve this, deep learning-based post-processing approaches are being developed. Therefore, we aimed to compare the objective and subjective image quality of different reconstruction techniques and a deep learning-based software on non-contrast chest and low-dose abdominal CTs. In this retrospective study, non-contrast chest CTs of patients suspected of COVID-19 pneumonia and low-dose abdominal CTs suspected of urolithiasis were analysed. All images were reconstructed using filtered back-projection (FBP) and were post-processed using an artificial intelligence (AI)-based commercial software (PixelShine (PS)). Additional iterative reconstruction (IR) was performed for abdominal CTs. Objective and subjective image quality were evaluated. AI-based post-processing led to an overall significant noise reduction independent of the protocol (chest or abdomen) while maintaining image information (max. difference in SNR 2.59 ± 2.9 and CNR 15.92 ± 8.9,

Identifiants

pubmed: 38535032
pii: diagnostics14060612
doi: 10.3390/diagnostics14060612
pii:
doi:

Types de publication

Journal Article

Langues

eng

Auteurs

Marcel A Drews (MA)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Aydin Demircioğlu (A)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Julia Neuhoff (J)

Faculty of Medicine, University Duisburg-Essen, Hufelandstraße 55, 45122 Essen, Germany.

Johannes Haubold (J)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Sebastian Zensen (S)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Marcel K Opitz (MK)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Michael Forsting (M)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Kai Nassenstein (K)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Denise Bos (D)

Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Hufelandstraße 55, 45147 Essen, Germany.

Classifications MeSH