Extended MRI-based PET motion correction for cardiac PET/MRI.

2-Dimensional image navigator Binning Motion correction PET/MRI Respiratory belt Signal-to-noise ratio

Journal

EJNMMI physics
ISSN: 2197-7364
Titre abrégé: EJNMMI Phys
Pays: Germany
ID NLM: 101658952

Informations de publication

Date de publication:
06 Apr 2024
Historique:
received: 22 08 2023
accepted: 25 03 2024
medline: 6 4 2024
pubmed: 6 4 2024
entrez: 6 4 2024
Statut: epublish

Résumé

A 2D image navigator (iNAV) based 3D whole-heart sequence has been used to perform MRI and PET non-rigid respiratory motion correction for hybrid PET/MRI. However, only the PET data acquired during the acquisition of the 3D whole-heart MRI is corrected for respiratory motion. This study introduces and evaluates an MRI-based respiratory motion correction method of the complete PET data. Twelve oncology patients scheduled for an additional cardiac A pair-wise comparison showed that the SUV The proposed respiratory motion correction method for hybrid PET/MRI improved the image quality of cardiovascular PET scans by increased SUV

Identifiants

pubmed: 38581561
doi: 10.1186/s40658-024-00637-z
pii: 10.1186/s40658-024-00637-z
doi:

Types de publication

Journal Article

Langues

eng

Pagination

36

Subventions

Organisme : HORIZON EUROPE Marie Sklodowska-Curie Actions
ID : 722609

Informations de copyright

© 2024. The Author(s).

Références

Melsaether AN, Raad RA, Pujara AC, Ponzo FD, Pysarenko KM, Jhaveri K, et al. Comparison of whole-body (18)F FDG PET/MR Imaging and whole-body (18)F FDG PET/CT in terms of lesion detection and radiation dose in patients with breast cancer. Radiology. 2016;281:193–202. https://doi.org/10.1148/radiol.2016151155 .
doi: 10.1148/radiol.2016151155 pubmed: 27023002
Aizaz M, Moonen RPM, van der Pol JAJ, Prieto C, Botnar RM, Kooi ME. PET/MRI of atherosclerosis. Cardiovasc Diagn Ther. 2020;10:1120–39. https://doi.org/10.21037/cdt.2020.02.09 .
doi: 10.21037/cdt.2020.02.09 pubmed: 32968664 pmcid: 7487378
Bustin A, Ginami G, Cruz G, Correia T, Ismail TF, Rashid I, et al. Five-minute whole-heart coronary MRA with sub-millimeter isotropic resolution, 100% respiratory scan efficiency, and 3D-PROST reconstruction. Magn Reson Med. 2019;81:102–15. https://doi.org/10.1002/mrm.27354 .
doi: 10.1002/mrm.27354 pubmed: 30058252
Ehman RL, McNamara MT, Pallack M, Hricak H, Higgins CB. Magnetic resonance imaging with respiratory gating: techniques and advantages. AJR Am J Roentgenol. 1984;143:1175–82. https://doi.org/10.2214/ajr.143.6.1175 .
doi: 10.2214/ajr.143.6.1175 pubmed: 6333787
Filipovic M, Vuissoz P-A, Codreanu A, Claudon M, Felblinger J. Motion compensated generalized reconstruction for free-breathing dynamic contrast-enhanced MRI. Magn Reson Med. 2011;65:812–22. https://doi.org/10.1002/mrm.22644 .
doi: 10.1002/mrm.22644 pubmed: 20882640
Henningsson M, Botnar RM. Advanced respiratory motion compensation for coronary MR angiography. Sensors. 2013;13:6882–99. https://doi.org/10.3390/s130606882 .
doi: 10.3390/s130606882 pubmed: 23708271 pmcid: 3715228
Larson AC, White RD, Laub G, McVeigh ER, Li D, Simonetti OP. Self-gated cardiac cine MRI. Magn Reson Med. 2004;51:93–102. https://doi.org/10.1002/mrm.10664 .
doi: 10.1002/mrm.10664 pubmed: 14705049 pmcid: 2396326
Piccini D, Littmann A, Nielles-Vallespin S, Zenge MO. Respiratory self-navigation for whole-heart bright-blood coronary MRI: Methods for robust isolation and automatic segmentation of the blood pool. Magn Reson Med. 2012;68:571–9. https://doi.org/10.1002/mrm.23247 .
doi: 10.1002/mrm.23247 pubmed: 22213169
Addy NO, Ingle RR, Luo J, Baron CA, Yang PC, Hu BS, et al. 3D image-based navigators for coronary MR angiography. Magn Reson Med. 2017;77:1874–83. https://doi.org/10.1002/mrm.26269 .
doi: 10.1002/mrm.26269 pubmed: 27174590
Cruz G, Atkinson D, Henningsson M, Botnar RM, Prieto C. Highly efficient nonrigid motion-corrected 3D whole-heart coronary vessel wall imaging. Magn Reson Med. 2017;77:1894–908. https://doi.org/10.1002/mrm.26274 .
doi: 10.1002/mrm.26274 pubmed: 27221073
Henningsson M, Smink J, Razavi R, Botnar RM. Prospective respiratory motion correction for coronary MR angiography using a 2D image navigator. Magn Reson Med. 2013;69:486–94. https://doi.org/10.1002/mrm.24280 .
doi: 10.1002/mrm.24280 pubmed: 22529009
Kawaji K, Spincemaille P, Nguyen TD, Thimmappa N, Cooper MA, Prince MR, et al. Direct coronary motion extraction from a 2D fat image navigator for prospectively gated coronary MR angiography. Magn Reson Med. 2014;71:599–607. https://doi.org/10.1002/mrm.24698 .
doi: 10.1002/mrm.24698 pubmed: 23504975
Keegan J, Gatehouse PD, Yang G-Z, Firmin DN. Non-model-based correction of respiratory motion using beat-to-beat 3D spiral fat-selective imaging. J Magn Reson Imaging. 2007;26:624–9. https://doi.org/10.1002/jmri.20941 .
doi: 10.1002/jmri.20941 pubmed: 17729350
Munoz C, Neji R, Cruz G, Mallia A, Jeljeli S, Reader AJ, et al. Motion-corrected simultaneous cardiac positron emission tomography and coronary MR angiography with high acquisition efficiency. Magn Reson Med. 2018;79:339–50. https://doi.org/10.1002/mrm.26690 .
doi: 10.1002/mrm.26690 pubmed: 28426162
Scott AD, Keegan J, Firmin DN. Motion in cardiovascular MR imaging. Radiology. 2009;250:331–51. https://doi.org/10.1148/radiol.2502071998 .
doi: 10.1148/radiol.2502071998 pubmed: 19188310
van Heeswijk RB, Bonanno G, Coppo S, Coristine A, Kober T, Stuber M. Motion compensation strategies in magnetic resonance imaging. Crit Rev Biomed Eng. 2012;40:99–119. https://doi.org/10.1615/critrevbiomedeng.v40.i2.20 .
doi: 10.1615/critrevbiomedeng.v40.i2.20 pubmed: 22668237
Lenz GW, Haacke EM, White RD. Retrospective cardiac gating: a review of technical aspects and future directions. Magn Reson Imaging. 1989;7:445–55. https://doi.org/10.1016/0730-725x(89)90399-8 .
doi: 10.1016/0730-725x(89)90399-8 pubmed: 2607896
Han F, Rapacchi S, Hu P. Prospective cardiac motion self-gating. Quant Imaging Med Surg. 2017;7:215–26. https://doi.org/10.21037/qims.2017.03.02 .
doi: 10.21037/qims.2017.03.02 pubmed: 28516047 pmcid: 5418143
Klein GJ, Reutter BW, Ho MH, Reed JH, Huesman RH. Real-time system for respiratory-cardiac gating in positron tomography. IEEE Trans Nucl Sci. 1998;45:2139–43. https://doi.org/10.1109/23.708323 .
doi: 10.1109/23.708323
Boucher L, Rodrigue S, Lecomte R, Bénard F. Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. J Nucl Med. 2004;45:214–9.
pubmed: 14960638
Nehmeh SA, Erdi YE, Ling CC, Rosenzweig KE, Squire OD, Braban LE, et al. Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. Med Phys. 2002;29:366–71. https://doi.org/10.1118/1.1448824 .
doi: 10.1118/1.1448824 pubmed: 11929020
Thielemans K, Schleyer P, Marsden PK, Manjeshwar RM, Wollenweber SD, Ganin A. Comparison of different methods for data-driven respiratory gating of PET data. 2013 IEEE nuclear science symposium and medical imaging conference (2013 NSS/MIC); 2013. pp. 1–4.
Robson PM, Trivieri M, Karakatsanis NA, Padilla M, Abgral R, Dweck MR, et al. Correction of respiratory and cardiac motion in cardiac PET/MR using MR-based motion modeling. Phys Med Biol. 2018;63:225011. https://doi.org/10.1088/1361-6560/aaea97 .
doi: 10.1088/1361-6560/aaea97 pubmed: 30426968 pmcid: 6425973
Schillaci O, Calabria F, Tavolozza M, Ciccio C, Carlani M, Caracciolo CR, et al. 18F-choline PET/CT physiological distribution and pitfalls in image interpretation: experience in 80 patients with prostate cancer. Nucl Med Commun. 2010;31:39–45. https://doi.org/10.1097/mnm.0b013e328330adc5 .
doi: 10.1097/mnm.0b013e328330adc5 pubmed: 19972635
Munoz C, Kunze KP, Neji R, Vitadello T, Rischpler C, Botnar RM, et al. Motion-corrected whole-heart PET-MR for the simultaneous visualisation of coronary artery integrity and myocardial viability: an initial clinical validation. Eur J Nucl Med Mol Imaging. 2018;45:1975–86. https://doi.org/10.1007/s00259-018-4047-7 .
doi: 10.1007/s00259-018-4047-7 pubmed: 29754161 pmcid: 6132558
Martinez-Möller A, Souvatzoglou M, Delso G, Bundschuh RA, Chefd’hotel C, Ziegler SI, et al. Tissue classification as a potential approach for attenuation correction in whole-body PET/MRI: evaluation with PET/CT data. J Nucl Med. 2009;50:520–6. https://doi.org/10.2967/jnumed.108.054726 .
doi: 10.2967/jnumed.108.054726 pubmed: 19289430
Blumhagen JO, Ladebeck R, Fenchel M, Scheffler K. MR-based field-of-view extension in MR/PET: B0 homogenization using gradient enhancement (HUGE). Magn Reson Med. 2013;70:1047–57. https://doi.org/10.1002/mrm.24555 .
doi: 10.1002/mrm.24555 pubmed: 23203976
Varrone A, Sjöholm N, Eriksson L, Gulyás B, Halldin C, Farde L. Advancement in PET quantification using 3D-OP-OSEM point spread function reconstruction with the HRRT. Eur J Nucl Med Mol Imaging. 2009;36:1639–50. https://doi.org/10.1007/s00259-009-1156-3 .
doi: 10.1007/s00259-009-1156-3 pubmed: 19437012
Modat M, Ridgway GR, Taylor ZA, Lehmann M, Barnes J, Hawkes DJ, et al. Fast free-form deformation using graphics processing units. Comput Methods Programs Biomed. 2010;98:278–84. https://doi.org/10.1016/j.cmpb.2009.09.002 .
doi: 10.1016/j.cmpb.2009.09.002 pubmed: 19818524
Rueckert D, Sonoda LI, Hayes C, Hill DLG, Leach MO, Hawkes DJ. Nonrigid registration using free-form deformations: application to breast MR images. IEEE Trans Med Imaging. 1999;18:712–21. https://doi.org/10.1109/42.796284 .
doi: 10.1109/42.796284 pubmed: 10534053
Tong S, Alessio AM, Kinahan PE. Noise and signal properties in PSF-based fully 3D PET image reconstruction: an experimental evaluation. Phys Med Biol. 2010;55:1453–73. https://doi.org/10.1088/0031-9155/55/5/013 .
doi: 10.1088/0031-9155/55/5/013 pubmed: 20150683 pmcid: 2890317
Dahlbom M, Schiepers C, Czernin J. Comparison of noise equivalent count rates and image noise. IEEE Trans Nucl Sci. 2005;52:1386–90. https://doi.org/10.1109/TNS.2005.858176 .
doi: 10.1109/TNS.2005.858176
Walker MD, Morgan AJ, Bradley KM, McGowan DR. Data-driven respiratory gating outperforms device-based gating for clinical
doi: 10.2967/jnumed.120.242248 pubmed: 32245898
Munoz C, Ellis S, Nekolla SG, Kunze KP, Vitadello T, Neji R, et al. MR-guided motion-corrected PET image reconstruction for cardiac PET-MR. J Nucl Med. 2021. https://doi.org/10.2967/jnumed.120.254235 .
doi: 10.2967/jnumed.120.254235 pubmed: 34049978 pmcid: 8612202
Mayer J, Wurster TH, Schaeffter T, Landmesser U, Morguet A, Bigalke B, et al. Imaging coronary plaques using 3D motion-compensated [(18)F]NaF PET/MR. Eur J Nucl Med Mol Imaging. 2021;48:2455–65. https://doi.org/10.1007/s00259-020-05180-4 .
doi: 10.1007/s00259-020-05180-4 pubmed: 33474584 pmcid: 8241750
Kustner T, Schwartz M, Martirosian P, Gatidis S, Seith F, Gilliam C, et al. MR-based respiratory and cardiac motion correction for PET imaging. Med Image Anal. 2017;42:129–44. https://doi.org/10.1016/j.media.2017.08.002 .
doi: 10.1016/j.media.2017.08.002 pubmed: 28800546

Auteurs

Mueez Aizaz (M)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.

Jochem A J van der Pol (JAJ)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.

Alina Schneider (A)

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Camila Munoz (C)

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Robert J Holtackers (RJ)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.
School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.

Yvonne van Cauteren (Y)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Department of Cardiology, VieCuri Medical Centre, Venlo, The Netherlands.

Herman van Langen (H)

Department of Medical Physics and Devices, VieCuri Medical Centre, Venlo, The Netherlands.

Joan G Meeder (JG)

Department of Cardiology, VieCuri Medical Centre, Venlo, The Netherlands.

Braim M Rahel (BM)

Department of Cardiology, VieCuri Medical Centre, Venlo, The Netherlands.

Roel Wierts (R)

Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.

René M Botnar (RM)

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.
Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile.
Instituto de Ingeniería Biológica y Médica, Pontificia Universidad Católica de Chile, Santiago, Chile.

Claudia Prieto (C)

School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile.
Millenium Institute for Intelligent Healthcare Engineering iHEALTH, Santiago, Chile.

Rik P M Moonen (RPM)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands.
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands.

M Eline Kooi (ME)

CARIM, Cardiovascular Research Institute Maastricht, Maastricht University, Maastricht, The Netherlands. eline.kooi@mumc.nl.
Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht, The Netherlands. eline.kooi@mumc.nl.

Classifications MeSH