A Validated In-House Assay for HIV Drug Resistance Mutation Surveillance from Dried Blood Spot Specimens.
HIV
dried blood spots
drug resistance
surveillance
Journal
Journal of virological methods
ISSN: 1879-0984
Titre abrégé: J Virol Methods
Pays: Netherlands
ID NLM: 8005839
Informations de publication
Date de publication:
09 Apr 2024
09 Apr 2024
Historique:
received:
10
08
2023
revised:
28
03
2024
accepted:
05
04
2024
medline:
12
4
2024
pubmed:
12
4
2024
entrez:
11
4
2024
Statut:
aheadofprint
Résumé
Despite increasing scale-up of antiretroviral therapy (ART) coverage, challenges related to adherence and HIV drug resistance (HIVDR) remain. The high cost of HIVDR surveillance is a persistent challenge with implementation in resource-constrained settings. Dried blood spot (DBS) specimens have been demonstrated to be a feasible alternative to plasma or serum for HIVDR genotyping and are more suitable for lower resource settings. There is a need for affordable HIVDR genotyping assays which can amplify HIV-1 sequences from DBS specimens, particularly those with low viral loads, at a low cost. Here, we present an in-house assay capable of reliably amplifying HIV-1 protease and partial reverse transcriptase genes from DBS specimens, which covers the complete World Health Organization 2009 list of drug resistance mutations under surveillance. DBS specimens were prepared using whole blood spiked with HIV-1 at concentrations of 10,000, 5,000, 1,000, and 500 copies/mL (n=30 for each concentration). Specimens were tested in triplicate. A two-step approach was used consisting of cDNA synthesis followed by nested PCR. The limit of detection of the assay was calculated to be approximately 5,000 (95% CI: 3,200-10,700) copies/mL for the protease gene and 3,600 (95% CI: 2,200-10,000) copies/mL for reverse transcriptase. The assay was observed to be most sensitive with higher viral load specimens (97.8% [95% CI: 92.2-99.7]) for both protease and reverse transcriptase at 10,000 copies/mL with performance decreasing with the use of specimens with lower viral loads (46.7% [36.1-57.5] and 60.0% [49.1-70.2] at 500 copies/mL for protease and reverse transcriptase, respectively). Ultimately, this assay presents a promising opportunity for use in resource-constrained settings. Future work should involve validation under field conditions including sub-optimal storage conditions and preparation of DBS with fingerprick blood in order to accurately reflect real-world collection scenarios.
Identifiants
pubmed: 38604585
pii: S0166-0934(24)00063-6
doi: 10.1016/j.jviromet.2024.114939
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
114939Informations de copyright
Copyright © 2024. Published by Elsevier B.V.
Déclaration de conflit d'intérêts
Declaration of Competing Interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.