Evaluation of the shrinkage process of a neck remnant after stent-coil treatment of a cerebral aneurysm using silent magnetic resonance angiography and computational fluid dynamics analysis: illustrative case.

computational fluid dynamics magnetic resonance image neck remnant silent magnetic resonance angiography stent and coil embolization wall shear stress

Journal

Journal of neurosurgery. Case lessons
ISSN: 2694-1902
Titre abrégé: J Neurosurg Case Lessons
Pays: United States
ID NLM: 9918227275606676

Informations de publication

Date de publication:
15 Apr 2024
Historique:
received: 25 02 2024
accepted: 13 03 2024
medline: 15 4 2024
pubmed: 15 4 2024
entrez: 15 4 2024
Statut: epublish

Résumé

Silent magnetic resonance angiography (MRA) mitigates metal artifacts, facilitating clear visualization of neck remnants after stent and coil embolization of cerebral aneurysms. This study aims to scrutinize hemodynamics at the neck remnant by employing silent MRA and computational fluid dynamics. The authors longitudinally tracked images of a partially thrombosed anterior communicating artery aneurysm's neck remnant, which had been treated with stent-assisted coil embolization, using silent MRA over a decade. Computational fluid dynamics delineated the neck remnant's reduction process, evaluating hemodynamic parameters such as flow rate, wall shear stress magnitude and vector, and streamlines. The neck remnant exhibited diminishing surface area, volume, neck size, dome depth, and aspect ratio. Its reduction correlated with a decline in the flow rate ratio of the remnant dome to the inflow parent artery. Analysis delineated regions within the contracting neck remnant characterized by consistently low average wall shear stress magnitude and variation, accompanied by notable variations in wall shear stress vector directionality. Evaluation of neck remnants after stent-coil embolization is possible through silent MRA and computational fluid dynamics. Predicting the neck remnant reduction may be achievable through hemodynamic parameter analysis.

Sections du résumé

BACKGROUND BACKGROUND
Silent magnetic resonance angiography (MRA) mitigates metal artifacts, facilitating clear visualization of neck remnants after stent and coil embolization of cerebral aneurysms. This study aims to scrutinize hemodynamics at the neck remnant by employing silent MRA and computational fluid dynamics.
OBSERVATIONS METHODS
The authors longitudinally tracked images of a partially thrombosed anterior communicating artery aneurysm's neck remnant, which had been treated with stent-assisted coil embolization, using silent MRA over a decade. Computational fluid dynamics delineated the neck remnant's reduction process, evaluating hemodynamic parameters such as flow rate, wall shear stress magnitude and vector, and streamlines. The neck remnant exhibited diminishing surface area, volume, neck size, dome depth, and aspect ratio. Its reduction correlated with a decline in the flow rate ratio of the remnant dome to the inflow parent artery. Analysis delineated regions within the contracting neck remnant characterized by consistently low average wall shear stress magnitude and variation, accompanied by notable variations in wall shear stress vector directionality.
LESSONS CONCLUSIONS
Evaluation of neck remnants after stent-coil embolization is possible through silent MRA and computational fluid dynamics. Predicting the neck remnant reduction may be achievable through hemodynamic parameter analysis.

Identifiants

pubmed: 38621304
doi: 10.3171/CASE24141
pii: CASE24141
doi:
pii:

Types de publication

Journal Article

Langues

eng

Auteurs

Toru Satoh (T)

1Departments of Neurological Surgery, Ryofukai Satoh Neurosurgical Hospital, Hiroshima, Japan.

Kenji Sugiu (K)

2Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and.

Masafumi Hiramatsu (M)

2Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and.

Jun Haruma (J)

2Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan; and.

Isao Date (I)

3Okayama Rosai Hospital, Okayama, Japan.

Classifications MeSH