Intraoperative and Intraprocedural Use of 3-Dimensional Transesophageal Echocardiography: An International European Association of Cardiothoracic Anesthesia and Intensive Care Survey of Cardiac Surgical Centers.
3D
TEE
cardiac surgery
intraoperative
survey
transesophageal echocardiography
Journal
Journal of cardiothoracic and vascular anesthesia
ISSN: 1532-8422
Titre abrégé: J Cardiothorac Vasc Anesth
Pays: United States
ID NLM: 9110208
Informations de publication
Date de publication:
09 Mar 2024
09 Mar 2024
Historique:
received:
21
02
2024
accepted:
28
02
2024
medline:
17
4
2024
pubmed:
17
4
2024
entrez:
16
4
2024
Statut:
aheadofprint
Résumé
To assess the intraoperative use of 3-dimensional transesophageal echocardiography (3D TEE) in cardiac surgical centers, the authors created a survey aimed at evaluating the availability of equipment and the use of 3D TEE for specific surgical and interventional procedures and single-image modalities. The respondents were asked to identify the perceived impact on patient management and current limitations to its routine use. A multiple choice 25-question online survey submitted to the members of the European Association of Cardiothoracic Anesthesia and Intensive Care (EACTAIC) on December 6, 2021, and closed on January 31, 2022. An online survey. Registered EACTAIC members in 2021. None. A total of 239 respondents from 44 different countries took part in the survey (27% of the total 903 EACTAIC members). Most respondents (59%) were TEE-certified by the National Board of Echocardiography, European Association of Cardiovascular Imaging (EACVI/EACTAIC), or had a national certificate. Of the respondents, 68% had no formal 3D TEE training. Eight percent of respondents had no 3D machines, whereas 40% had one for each operating room, and 33% had only one for the entire operating room block. 3D TEE was performed most frequently in more than 67% of cases for mitral valve surgery, and in more than 54% of cases for mitral and tricuspid clips, aortic valve, tricuspid valve, and aortic surgery. Current guidelines suggest integrating 3D TEE into all comprehensive examinations. The authors' survey reported that intraoperative 3D TEE was used in the majority of mitral valve surgery and only one-half of the other valve surgeries and transcatheter procedures. Its use may be explained by the availability of 3D machines, trained personnel, and limited time to perform TEE in the operating room. Educational initiatives for training in 3D TEE may further increase its routine use.
Identifiants
pubmed: 38627172
pii: S1053-0770(24)00165-4
doi: 10.1053/j.jvca.2024.02.042
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest None.