Measurement of stapes footplate thickness using ultra-high-resolution computed tomography: stapes axial plane correlates better with otosclerosis than lateral semicircular canal plane.

CT Otosclerosis semi-circular canals stapes temporal bone ultra-high resolution

Journal

Acta oto-laryngologica
ISSN: 1651-2251
Titre abrégé: Acta Otolaryngol
Pays: England
ID NLM: 0370354

Informations de publication

Date de publication:
25 Apr 2024
Historique:
medline: 25 4 2024
pubmed: 25 4 2024
entrez: 25 4 2024
Statut: aheadofprint

Résumé

Stapes footplate thickness measurement using ultra-high-resolution CT has been described only in the lateral semicircular canal plane. The purpose of this study was to compare stapes footplate thickness between the lateral semicircular canal and stapes axial planes in patients with otosclerosis compared to controls. We performed a retrospective single-center study of patients undergoing high-resolution temporal bone CT. Two radiologists measured stapes footplate thickness in both the lateral semicircular canal and stapes axial planes. Between February 2020 and October 2022, we collected 81 ears from 49 patients (75% of women; mean age 51.22 ± 16.6 years, 17 otosclerosis, and 64 controls). In the stapes axial plane, there was a significant anterior thickening in otosclerosis patients (Reader 1: 0.52 ± 0.12 [0.3-0.7] vs. 0.41 ± 0.08 [0.3-0.6], The stapes footplate was thickened at its AC in otosclerosis patients using only the stapes axial plane. We propose to use the stapes axial plane instead of the lateral semicircular canal plane when analyzing the stapes.

Sections du résumé

BACKGROUND, AIMS UNASSIGNED
Stapes footplate thickness measurement using ultra-high-resolution CT has been described only in the lateral semicircular canal plane. The purpose of this study was to compare stapes footplate thickness between the lateral semicircular canal and stapes axial planes in patients with otosclerosis compared to controls.
MATERIAL AND METHODS UNASSIGNED
We performed a retrospective single-center study of patients undergoing high-resolution temporal bone CT. Two radiologists measured stapes footplate thickness in both the lateral semicircular canal and stapes axial planes.
RESULTS UNASSIGNED
Between February 2020 and October 2022, we collected 81 ears from 49 patients (75% of women; mean age 51.22 ± 16.6 years, 17 otosclerosis, and 64 controls). In the stapes axial plane, there was a significant anterior thickening in otosclerosis patients (Reader 1: 0.52 ± 0.12 [0.3-0.7] vs. 0.41 ± 0.08 [0.3-0.6],
CONCLUSION UNASSIGNED
The stapes footplate was thickened at its AC in otosclerosis patients using only the stapes axial plane.
SIGNIFICANCE UNASSIGNED
We propose to use the stapes axial plane instead of the lateral semicircular canal plane when analyzing the stapes.

Identifiants

pubmed: 38662875
doi: 10.1080/00016489.2024.2340083
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

1-7

Auteurs

Romain Gillet (R)

Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Université de Lorraine, INSERM, IADI, Nancy, France.
Université de Lorraine, CIC, Innovation Technologique, University Hospital Center of Nancy, Nancy, France.

Michael Eliezer (M)

Department of Radiology, Lariboisière Hospital, Paris, France.

Gabriela Hossu (G)

Université de Lorraine, INSERM, IADI, Nancy, France.
Université de Lorraine, CIC, Innovation Technologique, University Hospital Center of Nancy, Nancy, France.

Charles Lombard (C)

Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.

Fatma Boubaker (F)

Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.

Alain Blum (A)

Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Université de Lorraine, INSERM, IADI, Nancy, France.
Université de Lorraine, CIC, Innovation Technologique, University Hospital Center of Nancy, Nancy, France.

Pedro Augusto Gondim Teixeira (PA)

Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
Université de Lorraine, INSERM, IADI, Nancy, France.
Université de Lorraine, CIC, Innovation Technologique, University Hospital Center of Nancy, Nancy, France.

Cécile Parietti-Winkler (C)

ENT Surgery Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.

Classifications MeSH