Stable measurement of chemistry, immunochemistry, and hematology analytes in a heparin-based anticoagulant with iloprost additive: A promising candidate for the polyvalent blood collection tube.
anticoagulants
biochemistry
blood specimen collection
hematology
iloprost
Journal
International journal of laboratory hematology
ISSN: 1751-553X
Titre abrégé: Int J Lab Hematol
Pays: England
ID NLM: 101300213
Informations de publication
Date de publication:
02 May 2024
02 May 2024
Historique:
received:
11
01
2024
accepted:
09
04
2024
medline:
2
5
2024
pubmed:
2
5
2024
entrez:
2
5
2024
Statut:
aheadofprint
Résumé
A polyvalent blood collection tube could potentially reduce the number and volume of blood samples drawn from patients and reduce the risk of tube mix-ups in a point-of-care setting in the emergency department and the intensive care unit. Four different concentrations of our experimental heparin anticoagulant with iloprost additive (HEP-ILOP 50 nM, 150 nM, 1000 nM, and 10 μM, respectively) were tested for significant differences and bias performance specifications against EDTA for 29 hematology analytes, and the highest concentration (HEP-ILOP 10 μM) against lithium heparin for 14 chemistry and immunochemistry analytes. Samples were drawn from 79 consenting subjects from the Oncology Department (n = 38) and the Intensive and Intermediary Care Unit (n = 41). For hematology analytes, the HEP-ILOP formulation generally provided stable measurement within optimal requirements within 5 h after sampling (mean 104 ± 56 min), with very little difference between the four HEP-ILOP concentrations. Because of differences in platelet and red blood cell swelling between EDTA and HEP-ILOP, all size-dependent analytes required proportional factorization to produce similar results. Platelet count by impedance similarly required factorization, whereas the fluorescent method provided results identical with EDTA. Chemistry and immunochemistry analytes were within optimal requirements except for potassium, lactate dehydrogenase, and glucose, indicating a cytoprotective effect of iloprost reducing cell metabolism and rupture, thereby producing results closer to in vivo conditions. Our novel dry-sprayed anticoagulant formulation, HEP-ILOP, is a promising candidate for a polyvalent blood collection tube, enabling the analysis of hematology, chemistry, and immunochemistry analytes in the same tube.
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Subventions
Organisme : Innovationsfonden
Organisme : Radiometer Medical ApS
Informations de copyright
© 2024 The Authors. International Journal of Laboratory Hematology published by John Wiley & Sons Ltd.
Références
Florkowski C, Don‐Wauchope A, Gimenez N, Rodriguez‐Capote K, Wils J, Zemlin A. Point‐of‐care testing (POCT) and evidence‐based laboratory medicine (EBLM)–does it leverage any advantage in clinical decision making? Crit Rev Clin Lab Sci. 2017;54(7–8):471‐494. doi:10.1080/10408363.2017.1399336
Lewandrowski K, Flood JG, Tochka L, Lee‐Lewandrowski E. Implementation of a point‐of‐care satellite laboratory (kiosk) in the emergency department of an academic medical center: an 8‐year experience at the Massachusetts General Hospital. Point Care. 2011;10(2):93‐97. doi:10.1097/POC.0b013e31821c6bb3
Jakacka N, Snarski E, Mekuria S. Prevention of iatrogenic anemia in critical and neonatal care. Adv Clin Exp Med. 2016;25(1):191‐197. doi:10.17219/acem/32065
Casagranda I. Point‐of‐care testing in critical care: the clinician's point of view. Clin Chem Lab Med. 2010;48(7):931‐934. doi:10.1515/CCLM.2010.191
Radziwon‐Balicka A, Wiwe EF, Jensen T, et al. Evaluation of a novel heparin‐iloprost‐based antithrombotic formulation blood collection tube for clinical usage. Clin Chim Acta. 2022;537:87‐95. doi:10.1016/j.cca.2022.10.006
Grant SM, Goa KL. Iloprost. A review of its pharmacodynamic and pharmacokinetic properties, and therapeutic potential in peripheral vascular disease, myocardial ischaemia and extracorporeal circulation procedures. Drugs. 1992;43(6):889‐924. doi:10.2165/00003495‐199243060‐00008
Friedewald WT, Levy RI, Fredrickson DS. Estimation of the concentration of low‐density lipoprotein cholesterol in plasma, without use of the preparative ultracentrifuge. Clin Chem. 1972;18(6):499‐502.
Fraser CG, Hyltoft Petersen P, Libeer JC, Ricos C. Proposals for setting generally applicable quality goals solely based on biology. Ann Clin Biochem. 1997;34(Pt 1):8‐12. doi:10.1177/000456329703400103
Aarsand AK, Fernandez‐Calle P, Webster C, et al. The EFLM biological variation database. Accessed August 25, 2022. https://biologicalvariation.eu/
Ricós C, Cava F, García‐Lario JV, et al. Current databases on biological variation: pros, cons and progress. Scand J Clin Lab Invest. 1999;59(7):491‐500. doi:10.1080/00365519950185229
Kumura T, Hino M, Yamane T, Tatsumi N. Hirudin as an anticoagulant for both haematology and chemistry tests. J Autom Methods Manag Chem. 2000;22(4):109‐112. doi:10.1002/1098‐2825(2000)14:4<136::AID‐JCLA2>3.0.CO;2‐1
Thompson CB, Diaz DD, Quinn PG, Lapins M, Kurtz SR, Valeri CR. The role of anticoagulation in the measurement of platelet volumes. Am J Clin Pathol. 1983;80(3):327‐332. doi:10.1093/ajcp/80.3.327
Pennock CA, Jones KW. Effect of ethylene‐diamine‐tetra‐acetic acid (dipotassium salt) and heparin on the estimation of packed cell volume. J Clin Pathol. 1966;19(2):196‐199. doi:10.1136/jcp.19.2.196
Gulati GL, Hyland LJ, Kocher W, Schwarting R. Changes in automated complete blood cell count and differential leukocyte count results induced by storage of blood at room temperature. Arch Pathol Lab Med. 2002;126(3):336‐342. doi:10.5858/2002‐126‐0336‐ciacbc
Antwi‐Baffour S. Prolong storage of blood in EDTA has an effect on the morphology and osmotic fragility of erythrocytes. Int J Biomed Sci Eng. 2013;1(2):20. doi:10.11648/j.ijbse.20130102.11
Planas AT, Van Voolen GA, Kelly LA. Hyperglycemic macrocytosis in electronically determined mean corpuscular volume. Use of three different automatic cell counters. Ann Clin Lab Sci. 1985;15(4):286‐291.
Philipsen JP, Madsen KV. Hypo‐ and hypernatremia results in inaccurate erythrocyte mean corpuscular volume measurement in vitro, when using Sysmex XE 2100. Scand J Clin Lab Invest. 2015;75(7):588‐594. doi:10.3109/00365513.2015.1062534
Jurk K, Kehrel BE. Platelets: physiology and biochemistry. Semin Thromb Hemost. 2005;31(4):381‐392.
Kuse R, Schuster S, Schübbe H, Dix S, Hausmann K. Blood lymphocyte volumes and diameters in patients with chronic lymphocytic leukemia and normal controls. Blut. 1985;50(4):243‐248. doi:10.1007/BF00320301
Ting‐Beall HP, Needham D, Hochmuth RM. Volume and osmotic properties of human neutrophils. Blood. 1993;81(10):2774‐2780. doi:10.1182/blood.v81.10.2774.bloodjournal81102774
Wiedmeyer CE, Ruben D, Franklin C. Complete blood count, clinical chemistry, and serology profile by using a single tube of whole blood from mice. J Am Assoc Lab Anim Sci. 2007;46(2):59‐64.
Menssen HD, Melber K, Brandt N, Thiel E. The use of hirudin as universal anticoagulant in haematology, clinical chemistry and blood grouping. Clin Chem Lab Med. 2001;39(12):1267‐1277. doi:10.1515/CCLM.2001.204
Hudzik B, Korzonek‐Szlacheta I, Danikiewicz A, et al. Platelet volume measurements—EDTA, citrate, or both? Angiology. 2018;69(3):271. doi:10.1177/0003319717747154
Bath PM. The routine measurement of platelet size using sodium citrate alone as the anticoagulant. Thromb Haemost. 1993;70(4):687‐690.
Li G, Cabanero M, Wang Z, et al. Comparison of glucose determinations on blood samples collected in three types of tubes. Ann Clin Lab Sci. 2013;43(3):278‐284.
Menssen HD, Brandt N, Leben R, Müller F, Thiel E, Melber K. Measurement of hematological, clinical chemistry, and infection parameters from hirudinized blood collected in universal blood sampling tubes. Semin Thromb Hemost. 2001;27(4):349‐356. doi:10.1055/s‐2001‐16888