Four-Stroke Apparent Motion Can Effectively Induce Visual Self-Motion Perception: an Examination Using Expanding, Rotating, and Translating Motion.


Journal

Multisensory research
ISSN: 2213-4808
Titre abrégé: Multisens Res
Pays: Netherlands
ID NLM: 101604290

Informations de publication

Date de publication:
24 Apr 2024
Historique:
received: 31 08 2023
accepted: 04 04 2024
medline: 8 5 2024
pubmed: 8 5 2024
entrez: 7 5 2024
Statut: epublish

Résumé

The current investigation examined whether visual motion without continuous visual displacement could effectively induce self-motion perception (vection). Four-stroke apparent motions (4SAM) were employed in the experiments as visual inducers. The 4SAM pattern contained luminance-defined motion energy equivalent to the real motion pattern, and the participants perceived unidirectional motion according to the motion energy but without displacements (the visual elements flickered on the spot). The experiments revealed that the 4SAM stimulus could effectively induce vection in the horizontal, expanding, or rotational directions, although its strength was significantly weaker than that induced by the real-motion stimulus. This result suggests that visual displacement is not essential, and the luminance-defined motion energy and/or the resulting perceived motion of the visual inducer would be sufficient for inducing visual self-motion perception. Conversely, when the 4SAM and real-motion patterns were presented simultaneously, self-motion perception was mainly determined in accordance with real motion, suggesting that the real-motion stimulus is a predominant determinant of vection. These research outcomes may be worthy of considering the perceptual and neurological mechanisms underlying self-motion perception.

Identifiants

pubmed: 38714313
doi: 10.1163/22134808-bja10120
doi:

Types de publication

Journal Article Research Support, Non-U.S. Gov't

Langues

eng

Sous-ensembles de citation

IM

Pagination

163-184

Auteurs

Shinji Nakamura (S)

School of Psychology, Nihon Fukushi University, Mihama-cho, Okuda, Aichi, 470-3295 Japan.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH