Conduction disorders following transcatheter aortic valve replacement using acurate Neo2 transcatheter heart valve: A propensity matched analysis.
AVB
Conduction disturbances
LBBB
Pacemaker
TAVR
Journal
Cardiovascular revascularization medicine : including molecular interventions
ISSN: 1878-0938
Titre abrégé: Cardiovasc Revasc Med
Pays: United States
ID NLM: 101238551
Informations de publication
Date de publication:
05 May 2024
05 May 2024
Historique:
received:
14
02
2024
revised:
15
04
2024
accepted:
01
05
2024
medline:
9
5
2024
pubmed:
9
5
2024
entrez:
8
5
2024
Statut:
aheadofprint
Résumé
The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves. A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics. Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL. In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.
Sections du résumé
BACKGROUND
BACKGROUND
The ACURATE neo2 transcatheter aortic valve was developed to improve paravalvular leak (PVL) rates while maintaining low rates of conduction disturbances and permanent pacemaker implantation (PPMI) seen with its predecessor. We aimed to compare conduction disturbances rates of transcatheter aortic valve replacement (TAVR) using ACURATE Neo2 with other commonly used valves.
METHODS
METHODS
A retrospective analysis of the Israeli TAVR registry between the years 2014-2023 was performed to compare conduction disturbances and PVL rates, and procedural outcomes, among patients treated with ACURATE neo2, Edwards Sapien 3 (S3), and Evolut PRO valves. Propensity score matching was performed to compare groups with similar characteristics.
RESULTS
RESULTS
Following exclusion of patients with non-femoral access, unknown valve type, older-generation valves, and less commonly used valves or (n = 4387), our analysis included 3208 patients undergoing TAVR using ACURATE neo2, Edwards S3, and Evolut PRO valves. Propensity matched groups comprised 169 patients each. Rates of any conduction disturbances [left bundle branch block (LBBB), atrioventricular block, or PPMI] were lower in the ACURATE neo2 group compared to both other valves [15.8 %, S3-37.5 % (p < 0.001), Evolut PRO-27.5 % (p = 0.02)] as were LBBB rates [9.0 %, S3-31.3 % (p < 0.001); Evolut PRO-20.1 % (p = 0.01). Atrioventricular block and PPMI rates were lower without statistical significance, as were rates of above-moderate PVL.
CONCLUSIONS
CONCLUSIONS
In this analysis, TAVR using ACURATE neo2 was associated with a lower composite rate of conduction disturbances in comparison to the Evolut PRO and Edwards S3 valves, mainly due to lower left bundle branch block rates, with non-significantly lower rates of PPMI and PVL.
Identifiants
pubmed: 38719632
pii: S1553-8389(24)00460-3
doi: 10.1016/j.carrev.2024.05.002
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 Elsevier Inc. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest Prof. Ariel Finkelstein reports a relationship with Medtronic Inc. that includes: consulting or advisory. Prof. Ariel Finkelstein reports a relationship with Edwards Lifesciences Corporation that includes: consulting or advisory. Prof. Amir Halkin reports a relationship with Abbott Laboratories that includes: consulting or advisory. Prof. Amir Halkin reports a relationship with Boston Scientific Corp that includes: consulting or advisory. Other authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.