Three-dimensional assessment of image distortion induced by active cardiac implants in 3.0T CMR.


Journal

Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288

Informations de publication

Date de publication:
15 05 2024
Historique:
received: 13 09 2023
accepted: 03 05 2024
medline: 16 5 2024
pubmed: 16 5 2024
entrez: 15 5 2024
Statut: epublish

Résumé

CMR at 3.0T in the presence of active cardiac implants remains a challenge due to susceptibility artifacts. Beyond a signal void that cancels image information, magnetic field inhomogeneities may cause distorted appearances of anatomical structures. Understanding influencing factors and the extent of distortion are a first step towards optimizing the image quality of CMR with active implants at 3.0T. All measurements were obtained at a clinical 3.0T scanner. An in-house designed phantom with a 3D cartesian grid of water filled spheres was used to analyze the distortion caused by four representative active cardiac devices (cardiac loop recorder, pacemaker, 2 ICDs). For imaging a gradient echo (3D-TFE) sequence and a turbo spin echo (2D-TSE) sequence were used. The work defines metrics to quantify the different features of distortion such as changes in size, location and signal intensity. It introduces a specialized segmentation technique based on a reaction-diffusion-equation. The distortion features are dependent on the amount of magnetic material in the active implants and showed a significant increase when measured with the 3D TFE compared to the 2D TSE. This work presents a quantitative approach for the evaluation of image distortion at 3.0T caused by active cardiac implants and serves as foundation for both further optimization of sequences and devices but also for planning of imaging procedures.

Identifiants

pubmed: 38750100
doi: 10.1038/s41598-024-61283-0
pii: 10.1038/s41598-024-61283-0
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

11130

Informations de copyright

© 2024. The Author(s).

Références

Schulz-Menger, J. et al. Standardized image interpretation and post-processing in cardiovascular magnetic resonance - 2020 update: Society for cardiovascular magnetic resonance (SCMR): Board of trustees task force on standardized post-processing. J. Cardiovasc. Magn. Reson. 22(1), 19 (2020).
doi: 10.1186/s12968-020-00610-6 pubmed: 32160925 pmcid: 7066763
Raatikainen, M. J. P. et al. A decade of information on the use of cardiac implantable electronic devices and interventional electrophysiological procedures in the European Society of Cardiology Countries: 2017 Report from the European Heart Rhythm Association. Europace 19(suppl_2), ii1–ii90 (2017).
doi: 10.1093/europace/eux258 pubmed: 28903470
Duru, F. et al. Pacing in magnetic resonance imaging environment: Clinical and technical considerations on compatibility. Eur. Heart J. 22(2), 113–124 (2001).
doi: 10.1053/euhj.2000.2149 pubmed: 11161913
Luechinger, R., Zeijlemaker, V. A., Boesiger, P. & Duru, F. Potential harmful effects of magnetic resonance imaging in pacemaker patients should not be underestimated. Europace 8(5), 389–390 (2006).
doi: 10.1093/europace/eul027 pubmed: 16636002
Luechinger, R. et al. In vivo heating of pacemaker leads during magnetic resonance imaging. Eur. Heart J. 26(4), 376–83 (2005).
doi: 10.1093/eurheartj/ehi009 pubmed: 15618060
Naehle, C. P. et al. Safety, feasibility, and diagnostic value of cardiac magnetic resonance imaging in patients with cardiac pacemakers and implantable cardioverters/defibrillators at 1.5 T. Am. Heart J. 161(6), 1096–105 (2011).
doi: 10.1016/j.ahj.2011.03.007 pubmed: 21641356
Sommer, T. et al. MR imaging in patients with cardiac pacemakers and implantable cardioverter defibrillators. Rofo 189(3), 204–217 (2017).
doi: 10.1055/s-0043-102029 pubmed: 28201839
Muthalaly, R. G., Nerlekar, N., Ge, Y., Kwong, R. Y. & Nasis, A. MRI in patients with cardiac implantable electronic devices. Radiology 289(2), 281–292 (2018).
doi: 10.1148/radiol.2018180285 pubmed: 30251926
Klein-Wiele, O. et al. Cardiovascular magnetic resonance in patients with magnetic resonance conditional pacemaker systems at 1.5 T: Influence of pacemaker related artifacts on image quality including first pass perfusion, aortic and mitral valve assessment, flow measurement, short tau inversion recovery and T1-weighted imaging. Int. J. Cardiovasc. Imaging 33(3), 383–94 (2017).
doi: 10.1007/s10554-016-1012-z pubmed: 27815793
Ranjan, R. et al. Wideband late gadolinium enhanced magnetic resonance imaging for imaging myocardial scar without image artefacts induced by implantable cardioverter-defibrillator: A feasibility study at 3 T. Europace 17(3), 483–488 (2015).
doi: 10.1093/europace/euu263 pubmed: 25336666
Patel, H. N. et al. Impact of wideband cardiac magnetic resonance on diagnosis, decision-making and outcomes in patients with implantable cardioverter defibrillators. Eur. Heart J. Cardiovasc. Imaging 24(2), 181–189 (2023).
doi: 10.1093/ehjci/jeac227 pubmed: 36458878
Oshinski, J. N., Delfino, J. G., Sharma, P., Gharib, A. M. & Pettigrew, R. I. Cardiovascular magnetic resonance at 3.0 T: Current state of the art. J. Cardiovasc. Magn. Reson. 12, 55 (2010).
doi: 10.1186/1532-429X-12-55 pubmed: 20929538 pmcid: 2964699
Hilbert, S. et al. Cardiovascular magnetic resonance imaging in patients with cardiac implantable electronic devices: A device-dependent imaging strategy for improved image quality. Eur. Heart J. Cardiovasc. Imaging 19(9), 1051–1061 (2018).
doi: 10.1093/ehjci/jex243 pubmed: 29048460
Löbe, S. et al. Evaluation of the right heart using cardiovascular magnetic resonance imaging in patients with cardiac devices. Int. J. Cardiol. 316, 266–271 (2020).
doi: 10.1016/j.ijcard.2020.05.021 pubmed: 32389768
Sasaki, T. et al. Quantitative assessment of artifacts on cardiac magnetic resonance imaging of patients with pacemakers and implantable cardioverter-defibrillators. Circ. Cardiovasc. Imaging 4(6), 662–670 (2011).
doi: 10.1161/CIRCIMAGING.111.965764 pubmed: 21946701 pmcid: 3218212
Stevens, S. M. et al. Device artifact reduction for magnetic resonance imaging of patients with implantable cardioverter-defibrillators and ventricular tachycardia: Late gadolinium enhancement correlation with electroanatomic mapping. Heart Rhythm 11(2), 289–298 (2014).
doi: 10.1016/j.hrthm.2013.10.032 pubmed: 24140812
Reiter, T., Weiss, I., Weber, O. M. & Bauer, W. R. Signal voids of active cardiac implants at 3.0 T CMR. Sci. Rep. 12(1), 6285 (2022).
doi: 10.1038/s41598-022-09690-z pubmed: 35428775 pmcid: 9014817
ASTM International SF. ASTM F2119 - 07(2013): Standard test method for evaluation of MR image artifacts from passive implants (2013).
Koff, M. F., Burge, A. J., Koch, K. M. & Potter, H. G. Imaging near orthopedic hardware. J. Magn. Reson. Imaging 46(1), 24–39 (2017).
doi: 10.1002/jmri.25577 pubmed: 28152257 pmcid: 5464983
Koff, M. F., Shah, P., Koch, K. M. & Potter, H. G. Quantifying image distortion of orthopedic materials in magnetic resonance imaging. J. Magn. Reson. Imaging 38(3), 610–618 (2013).
doi: 10.1002/jmri.23991 pubmed: 23292702
Slagowski, J. M. et al. A modular phantom and software to characterize 3D geometric distortion in MRI. Phys. Med. Biol. https://doi.org/10.1088/1361-6560/ab9c64 (2020).
doi: 10.1088/1361-6560/ab9c64 pubmed: 32531763 pmcid: 7772054
R2020a- Updates to the MATLAB and Simulink product families - MATLAB & Simulink (mathworks.com).
Rashid, S. et al. Improved late gadolinium enhancement MR imaging for patients with implanted cardiac devices. Radiology 270(1), 269–274 (2014).
doi: 10.1148/radiol.13130942 pubmed: 24086074 pmcid: 4228714
Schwitter, J. et al. Image quality of cardiac magnetic resonance imaging in patients with an implantable cardioverter defibrillator system designed for the magnetic resonance imaging environment. Circ. Cardiovasc. Imaging https://doi.org/10.1161/CIRCIMAGING.115.004025 (2016).
doi: 10.1161/CIRCIMAGING.115.004025 pubmed: 27511976
Wang, D. & Doddrell, D. M. A proposed scheme for comprehensive characterization of the measured geometric distortion in magnetic resonance imaging using a three-dimensional phantom. Med. Phys. 31(8), 2212–2218 (2004).
doi: 10.1118/1.1767051 pubmed: 15377086
Johnston, K. W. et al. Suggested standards for reporting on arterial aneurysms. Subcommittee on reporting standards for arterial aneurysms, Ad Hoc Committee on Reporting Standards, Society for Vascular Surgery and North American Chapter, International Society for Cardiovascular Surgery. J. Vasc. Surg. 13(3), 452–8 (1991).
doi: 10.1067/mva.1991.26737 pubmed: 1999868

Auteurs

Theresa Reiter (T)

Department of Internal Medicine I, Cardiology, University Hospital Wuerzburg, Oberduerbacher Strasse 6a, 97080, Wuerzburg, Germany. Reiter_t@ukw.de.
German Heart Center Munich, Electrophysiology, Munich, Germany. Reiter_t@ukw.de.

Ingo Weiss (I)

BIOTRONIK SE & Co. KG, Berlin, Germany.

Oliver M Weber (OM)

Philips GmbH, Hamburg, Germany.

Wolfgang R Bauer (WR)

Department of Internal Medicine I, Cardiology, University Hospital Wuerzburg, Oberduerbacher Strasse 6a, 97080, Wuerzburg, Germany.

Articles similaires

[Redispensing of expensive oral anticancer medicines: a practical application].

Lisanne N van Merendonk, Kübra Akgöl, Bastiaan Nuijen
1.00
Humans Antineoplastic Agents Administration, Oral Drug Costs Counterfeit Drugs

Smoking Cessation and Incident Cardiovascular Disease.

Jun Hwan Cho, Seung Yong Shin, Hoseob Kim et al.
1.00
Humans Male Smoking Cessation Cardiovascular Diseases Female
Humans United States Aged Cross-Sectional Studies Medicare Part C
1.00
Humans Yoga Low Back Pain Female Male

Classifications MeSH