Double Electrode Experiments Reveal the Processes Occurring at PEDOT-Coated Neural Electrode Arrays.

bipotentiostat cyclic voltammetry (CV) electrochemical analysis poly(3,4-ethylenedioxythiophene):chloride (PEDOT:Cl) poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) tetrode

Journal

ACS applied materials & interfaces
ISSN: 1944-8252
Titre abrégé: ACS Appl Mater Interfaces
Pays: United States
ID NLM: 101504991

Informations de publication

Date de publication:
22 May 2024
Historique:
pubmed: 22 5 2024
medline: 22 5 2024
entrez: 22 5 2024
Statut: aheadofprint

Résumé

Neural electrodes have recently been developed with surface modifications of conductive polymers, in particular poly(3,4-ethylenedioxythiophene) (PEDOT), and extensively studied for their roles in recording and stimulation, aiming to improve their biocompatibility. In this work, the implications for the design of practical neural sensors are clarified, and systematic procedures for their preparation are reported. In particular, this study introduces the use of in vitro double electrode experiments to mimic the responses of neural electrodes with a focus on signal-recording electrodes modified with PEDOT. Specifically, potential steps on one unmodified electrode in an array are used to identify the responses for PEDOT doped with different anions and compared with that of a bare platinum (Pt) electrode. The response is shown to be related to the rearrangement of ions in solution near the detector electrode resulting from the potential step, with a current transient seen at the detector electrode. A rapid response for PEDOT doped with chloride (ca. 0.04 s) ions was observed and attributed to the fast movement of chloride ions in and out of the polymer film. In contrast, PEDOT doped with poly(styrenesulfonate) (PSS) responds much slower (ca. 2.2 s), and the essential immobility of polyanion constrains the direction of current flow.

Identifiants

pubmed: 38775098
doi: 10.1021/acsami.4c05204
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Auteurs

Yuanmin Zhang (Y)

Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, Great Britain.
Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, Great Britain.

Yuqi Chen (Y)

Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, Great Britain.

Sonia Contera (S)

Clarendon Laboratory, Department of Physics, University of Oxford, Parks Road, Oxford OX1 3PU, Great Britain.

Richard G Compton (RG)

Physical and Theoretical Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, Great Britain.

Classifications MeSH