Evaluation of short and mid-term clinical outcomes in patients with aortic coarctation treated with self-expandable stents.
Aortic coarctation
Peak gradient
Self-expandable stent
Sinus-XL
Uncovered stent
Journal
Scientific reports
ISSN: 2045-2322
Titre abrégé: Sci Rep
Pays: England
ID NLM: 101563288
Informations de publication
Date de publication:
23 05 2024
23 05 2024
Historique:
received:
05
02
2024
accepted:
20
05
2024
medline:
24
5
2024
pubmed:
24
5
2024
entrez:
23
5
2024
Statut:
epublish
Résumé
The present study aimed to evaluate the outcomes of percutaneous treatment of aortic coarctation using self-expandable uncovered Nitinol stents. We conducted a retrospective clinical data review of all patients with aortic coarctation and treated with self-expandable uncovered Nitinol stents at our institution between 2009 and 2019. The gradient pressure across the coarctation site was measured using aortography. Follow-up echocardiography and computed tomography angiography were performed to assess possible stent complications. A total of 127 stents were successfully implanted in 125 patients (64.8% males) with a mean age of 35.36 ± 11.9 years. The gradient across the coarctation site decreased significantly from 67.48 ± 14.79 to 5.04 ± 3.01 mmHg (P < 0.001) after self-expandable stent implantation. Systolic blood pressure (SBP) decreased significantly from 175.53 ± 15.99 to 147.22 ± 12.83 mmHg (P < 0.001) after self-expandable stenting. There were no major technical or clinical complications, including balloon rupture, aneurysmal formation, infection, secondary stent migration, thrombosis, death during the procedure, and in-hospital mortality. On a mean follow-up of 48 ± 23.6 months (12-120 months), the gradient [from 59.43 ± 15.42 to 3.72 ± 1.38 mmHg (P < 0.001)] and SBP [from 175.53 ± 15.99 to 127.99 ± 7.82 mmHg (P < 0.001)] decreased significantly. There was no mortality, aneurysmal formation in the stent site, dislocation, or aortic re-stenosis requiring intervention during mid-term follow-up. Treatment of aortic coarctation using a self-expandable uncovered nitinol stent is safe and effective with promising mid-term outcomes.
Identifiants
pubmed: 38783056
doi: 10.1038/s41598-024-62607-w
pii: 10.1038/s41598-024-62607-w
doi:
Substances chimiques
nitinol
2EWL73IJ7F
Alloys
0
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
11748Informations de copyright
© 2024. The Author(s).
Références
Ganigara, M. et al. Preoperative physiology, imaging, and management of coarctation of aorta in children. Semin. Cardiothorac. Vasc. Anesth. 23, 379–386. https://doi.org/10.1177/1089253219873004 (2019).
doi: 10.1177/1089253219873004
pubmed: 31535945
Chetan, D. & Mertens, L. L. Challenges in diagnosis and management of coarctation of the aorta. Curr. Opin. Cardiol. 37, 115–122. https://doi.org/10.1097/hco.0000000000000934 (2022).
doi: 10.1097/hco.0000000000000934
pubmed: 34857719
Fox, E. B., Latham, G. J., Ross, F. J. & Joffe, D. Perioperative and anesthetic management of coarctation of the aorta. Semin. Cardiothorac. Vasc. Anesth. 23, 212–224. https://doi.org/10.1177/1089253218821953 (2019).
doi: 10.1177/1089253218821953
pubmed: 30614372
Gholoobi, A. et al. Colchicine effectively attenuates inflammatory biomarker high-sensitivity C-reactive protein (hs-CRP) in patients with non-ST-segment elevation myocardial infarction: A randomised, double-blind, placebo-controlled clinical trial. Inflammopharmacology 29, 1379–1387. https://doi.org/10.1007/s10787-021-00865-0 (2021).
doi: 10.1007/s10787-021-00865-0
pubmed: 34420187
Ebrahimi, M. et al. Evaluation of long-term outcomes of percutaneous coronary intervention in patients with moderate to severe calcified coronary artery lesions. Health Sci. Rep. 6, e1588. https://doi.org/10.1002/hsr2.1588 (2023).
doi: 10.1002/hsr2.1588
pubmed: 37779669
pmcid: 10539625
Kim, Y. Y., Andrade, L. & Cook, S. C. Aortic coarctation. Cardiol. Clin. 38, 337–351. https://doi.org/10.1016/j.ccl.2020.04.003 (2020).
doi: 10.1016/j.ccl.2020.04.003
pubmed: 32622489
Arya, B. & Maskatia, S. A. Coarctation of the aorta: Prenatal assessment, postnatal management and neonatal outcomes. Semin. Perinatol. 46, 151584. https://doi.org/10.1016/j.semperi.2022.151584 (2022).
doi: 10.1016/j.semperi.2022.151584
pubmed: 35422354
Sistani, S. et al. The discovery of major heart risk factors among young patients with ischemic heart disease using k-means techniques. Int. Cardiovasc. Res. J. 13, 3 (2019).
Dastani, M. et al. Three months of combination therapy with nano-curcumin reduces the inflammation and lipoprotein (a) in type 2 diabetic patients with mild to moderate coronary artery disease: Evidence of a randomized, double-blinded, placebo-controlled clinical trial. Biofactors 49, 108–118. https://doi.org/10.1002/biof.1874 (2023).
doi: 10.1002/biof.1874
pubmed: 35674733
Luijendijk, P. et al. Surgical versus percutaneous treatment of aortic coarctation: New standards in an era of transcatheter repair. Expert Rev. Cardiovasc. Ther. 10, 1517–1531. https://doi.org/10.1586/erc.12.158 (2012).
doi: 10.1586/erc.12.158
pubmed: 23253276
Egan, M. & Holzer, R. J. Comparing balloon angioplasty, stenting and surgery in the treatment of aortic coarctation. Expert Rev. Cardiovasc. Ther. 7, 1401–1412. https://doi.org/10.1586/erc.09.111 (2009).
doi: 10.1586/erc.09.111
pubmed: 19900023
Forbes, T. J. et al. Comparison of surgical, stent, and balloon angioplasty treatment of native coarctation of the aorta: An observational study by the CCISC (Congenital Cardiovascular Interventional Study Consortium). J. Am. Coll. Cardiol. 58, 2664–2674. https://doi.org/10.1016/j.jacc.2011.08.053 (2011).
doi: 10.1016/j.jacc.2011.08.053
pubmed: 22152954
Harris, K. C., Du, W., Cowley, C. G., Forbes, T. J. & Kim, D. W. A prospective observational multicenter study of balloon angioplasty for the treatment of native and recurrent coarctation of the aorta. Catheteriz. Cardiovasc. Interv. 83, 1116–1123. https://doi.org/10.1002/ccd.25284 (2014).
doi: 10.1002/ccd.25284
Sadeghipour, P. et al. Balloon-expandable cheatham-platinum stents versus self-expandable nitinol stents in coarctation of aorta: A randomized controlled trial. JACC Cardiovasc. Interv. 15, 308–317. https://doi.org/10.1016/j.jcin.2021.11.025 (2022).
doi: 10.1016/j.jcin.2021.11.025
pubmed: 35144787
Haji Zeinali, A. M., Sadeghian, M., Qureshi, S. A. & Ghazi, P. Midterm to long-term safety and efficacy of self-expandable nitinol stent implantation for coarctation of aorta in adults. Catheter. Cardiovasc. Interv. 90, 425–431. https://doi.org/10.1002/ccd.27178 (2017).
doi: 10.1002/ccd.27178
pubmed: 28707350
Haji-Zeinali, A. M., Ghazi, P. & Alidoosti, M. Self-expanding nitinol stent implantation for treatment of aortic coarctation. J. Endovasc. Ther. 16, 224–232. https://doi.org/10.1583/08-2589.1 (2009).
doi: 10.1583/08-2589.1
pubmed: 19456194
de Wolf, M. A. et al. Short-term clinical experience with a dedicated venous nitinol stent: Initial results with the sinus-venous stent. Eur. J. Vasc. Endovasc. Surg. 50, 518–526. https://doi.org/10.1016/j.ejvs.2015.05.011 (2015).
doi: 10.1016/j.ejvs.2015.05.011
pubmed: 26187656
van Vuuren, T. M., de Wolf, M. A. & Wittens, C. H. Relevance of flexibility versus radial force in rigid versus more flexible venous stents? Phlebology 34, 459–465. https://doi.org/10.1177/0268355518819398 (2019).
doi: 10.1177/0268355518819398
pubmed: 30582738
Alkashkari, W., Albugami, S. & Hijazi, Z. M. Management of coarctation of the aorta in adult patients: State of the art. Korean Circ. J. 49, 298–313. https://doi.org/10.4070/kcj.2018.0433 (2019).
doi: 10.4070/kcj.2018.0433
pubmed: 30895757
pmcid: 6428953
Stines, J. R. & Holzer, R. J. Stenting of aortic coarctation: Technical considerations and procedural outcomes. Prog. Pediatr. Cardiol. 33, 161–167. https://doi.org/10.1016/j.ppedcard.2012.02.009 (2012).
doi: 10.1016/j.ppedcard.2012.02.009
Forbes, T. J. & Gowda, S. T. Intravascular stent therapy for coarctation of the aorta. Method. DeBakey Cardiovasc. J. 10, 82–87. https://doi.org/10.14797/mdcj-10-2-82 (2014).
doi: 10.14797/mdcj-10-2-82
Kische, S. et al. Percutaneous treatment of adult isthmic aortic coarctation. Circ. Cardiovasc. Interv. 8, e001799. https://doi.org/10.1161/CIRCINTERVENTIONS.114.001799 (2015).
doi: 10.1161/CIRCINTERVENTIONS.114.001799
pubmed: 25582143
Firoozi, A. et al. Self-expanding versus balloon-expandable stents in patients with isthmic coarctation of the aorta. Am. J. Cardiol. 122, 1062–1067 (2018).
doi: 10.1016/j.amjcard.2018.06.005
pubmed: 30139526
Langroodi, H. M. et al. Endovascular stents for coarctation of aorta in children and adolescents: Early and intermediate-term results. Tehran Univ. Med. J. 68, 341–347 (2010).
Kasar, T. et al. Balloon-expandable stents for native coarctation of the aorta in children and adolescents. Medicine 101, e32332. https://doi.org/10.1097/md.0000000000032332 (2022).
doi: 10.1097/md.0000000000032332
pubmed: 36595787
pmcid: 9794334
Sadeghipour, P. et al. Balloon-expandable cheatham-platinum stents versus self-expandable nitinol stents in coarctation of aorta: A randomized controlled trial. Cardiovasc. Interv. 15, 308–317 (2022).
Kenny, D. et al. Self-expanding and balloon expandable covered stents in the treatment of aortic coarctation with or without aneurysm formation. Catheteriz. Cardiovasc. Interv. 72, 65–71. https://doi.org/10.1002/ccd.21559 (2008).
doi: 10.1002/ccd.21559
Tyagi, S., Singh, S., Mukhopadhyay, S. & Kaul, U. A. Self- and balloon-expandable stent implantation for severe native coarctation of aorta in adults. Am. Heart J. 146, 920–928. https://doi.org/10.1016/S0002-8703(03)00434-4 (2003).
doi: 10.1016/S0002-8703(03)00434-4
pubmed: 14597945
Haddad, R. N. et al. Multicentre experience with optimus balloon-expandable cobalt-chromium stents in congenital heart disease interventions. Open Heart 10, 2157. https://doi.org/10.1136/openhrt-2022-002157 (2023).
doi: 10.1136/openhrt-2022-002157
Hatoum, I., Haddad, R. N., Saliba, Z. & Abdel Massih, T. Endovascular stent implantation for aortic coarctation: Parameters affecting clinical outcomes. Am. J. Cardiovasc. Dis. 10, 528–537 (2020).
pubmed: 33489455
pmcid: 7811920
Cheng, W. et al. Stent implantation and balloon angioplasty for native and recurrent coarctation of the aorta. Int. Heart J. 64, 10–21. https://doi.org/10.1536/ihj.21-643 (2023).
doi: 10.1536/ihj.21-643
pubmed: 36682763
Saadi, R. P., Saadi, E. K., Tagliari, A. P. & Saadi, M. P. Endovascular treatment of coarctation of the aorta with a self-expanding endoprosthesis: How I do it using the braile dominus(®) coarctation aorta device. Braz. J. Cardiovasc. Surg. 36, 817–821. https://doi.org/10.21470/1678-9741-2020-0345 (2021).
doi: 10.21470/1678-9741-2020-0345
pubmed: 34236790
pmcid: 8641778