Assessing the Impact of Various Decontamination Instruments on Titanium and Zirconia Dental Implants: An In Vitro Study.
abrasion
dental implants
particles
surface properties
titanium
zirconium
Journal
Dentistry journal
ISSN: 2304-6767
Titre abrégé: Dent J (Basel)
Pays: Switzerland
ID NLM: 101716125
Informations de publication
Date de publication:
09 May 2024
09 May 2024
Historique:
received:
18
03
2024
revised:
29
04
2024
accepted:
07
05
2024
medline:
24
5
2024
pubmed:
24
5
2024
entrez:
24
5
2024
Statut:
epublish
Résumé
This study investigates the impact of various instrumentation techniques on material removal and surface changes in titanium (Ti)- and zirconia (Zr) implant discs. Ti- and Zr discs were subjected to standardized experiments using various instruments including airflow, ultrasound, carbide, and diamond burs. Instrumentation was performed for 60 s with continuous automatic motion. Abrasion and changes in surface roughness were assessed using profilometry, while scanning electron microscopy was used to examine morphological changes and particle size. Carbide burs predominantly caused abrasion on Ti discs, while diamond burs caused more abrasion on Zr discs. The Ti discs were more susceptible to surface changes. However, among the materials tested, machined Zr discs treated with diamond burs produced the largest particle. In certain cases, a statistical significance (