What is the Optimal Nail Length to Treat Osteoporotic Subtrochanteric Fractures? A Finite Element Analysis.
Cephalomedullary nail
Finite element analysis
Fracture fixation
Hip fractures
Materials testing
Journal
Clinics in orthopedic surgery
ISSN: 2005-4408
Titre abrégé: Clin Orthop Surg
Pays: Korea (South)
ID NLM: 101505087
Informations de publication
Date de publication:
Jun 2024
Jun 2024
Historique:
received:
28
07
2023
revised:
22
01
2024
accepted:
22
01
2024
medline:
3
6
2024
pubmed:
3
6
2024
entrez:
3
6
2024
Statut:
ppublish
Résumé
Operative management with intramedullary nail fixation remains the definitive treatment of choice for osteoporotic subtrochanteric (ST) fractures; however, there remains no consensus regarding the proper nail length. We aimed to use 3-dimensional finite element (FE) analysis to determine the optimal nail length for the safe fixation of osteoporotic ST fractures. Nine modes of FE models were constructed using 9 different lengths of cephalomedullary nails (short nails: 170, 180, and 200 mm; long nails: 280, 300, 320, 340, 360, and 380 mm) from the same company. The interfragmentary motion was analyzed. Additionally, the peak von Mises stress (PVMS) in the cortical bone, cancellous bone of the femoral head, and the nail were measured, and the yielding risk for each subject was investigated. Long nails were associated with less interfragmentary motion. In the cortical bone, the PVMS of short nails was observed at the distal locking screw holes of the femoral medial cortex; however, in long nails, the PVMS was observed at the lag screw holes on the lateral cortex. The mean yielding risk of long nails was 40.1% lower than that of short nails. For the cancellous bone of the femoral head, the PVMS in all 9 FE models was in the same area: at the apex of the femoral head. There was no difference in the yielding risk between short and long nails. For implants, the PVMS was at the distal locking screw hole of the nail body in the short nails and the nail body at the fracture level in the long nails. The mean yielding risk was 74.9% lower for long nails than that for short nails. Compared to short nails, long nails with a length of 320 mm or more showed less interfragmentary motion and lower yielding risk in low-level osteoporotic ST fractures. The FE analysis supports long nails as a safer option than short nails, especially for treating transverse-type low-level osteoporotic ST fractures.
Sections du résumé
Background
UNASSIGNED
Operative management with intramedullary nail fixation remains the definitive treatment of choice for osteoporotic subtrochanteric (ST) fractures; however, there remains no consensus regarding the proper nail length. We aimed to use 3-dimensional finite element (FE) analysis to determine the optimal nail length for the safe fixation of osteoporotic ST fractures.
Methods
UNASSIGNED
Nine modes of FE models were constructed using 9 different lengths of cephalomedullary nails (short nails: 170, 180, and 200 mm; long nails: 280, 300, 320, 340, 360, and 380 mm) from the same company. The interfragmentary motion was analyzed. Additionally, the peak von Mises stress (PVMS) in the cortical bone, cancellous bone of the femoral head, and the nail were measured, and the yielding risk for each subject was investigated.
Results
UNASSIGNED
Long nails were associated with less interfragmentary motion. In the cortical bone, the PVMS of short nails was observed at the distal locking screw holes of the femoral medial cortex; however, in long nails, the PVMS was observed at the lag screw holes on the lateral cortex. The mean yielding risk of long nails was 40.1% lower than that of short nails. For the cancellous bone of the femoral head, the PVMS in all 9 FE models was in the same area: at the apex of the femoral head. There was no difference in the yielding risk between short and long nails. For implants, the PVMS was at the distal locking screw hole of the nail body in the short nails and the nail body at the fracture level in the long nails. The mean yielding risk was 74.9% lower for long nails than that for short nails.
Conclusions
UNASSIGNED
Compared to short nails, long nails with a length of 320 mm or more showed less interfragmentary motion and lower yielding risk in low-level osteoporotic ST fractures. The FE analysis supports long nails as a safer option than short nails, especially for treating transverse-type low-level osteoporotic ST fractures.
Identifiants
pubmed: 38827761
doi: 10.4055/cios23234
pmc: PMC11130630
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
363-373Informations de copyright
Copyright © 2024 by The Korean Orthopaedic Association.
Déclaration de conflit d'intérêts
CONFLICT OF INTEREST: No potential conflict of interest relevant to this article was reported.