Articular Fragment Detachment and Separate Fixation for the Treatment of Comminuted Patellar Fractures with Coronal Split Articular Fragments: Articular Detachment Technique.
Articular fragment detachment
Comminuted patellar fracture
Coronal split articular fragment
Inferior pole
Journal
Clinics in orthopedic surgery
ISSN: 2005-4408
Titre abrégé: Clin Orthop Surg
Pays: Korea (South)
ID NLM: 101505087
Informations de publication
Date de publication:
Jun 2024
Jun 2024
Historique:
received:
06
10
2023
revised:
09
12
2023
accepted:
02
01
2024
medline:
3
6
2024
pubmed:
3
6
2024
entrez:
3
6
2024
Statut:
ppublish
Résumé
Treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments is a challenge. To treat this difficult fracture, we perform articular fragment detachment and separate fixation for coronal split articular and inferior pole fragments. We aimed to evaluate the radiological and clinical outcomes of our technique in comminuted patellar fractures at least 1 year after surgery. Between January 2019 and June 2022, 15 patients diagnosed with comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments based on preoperative computed tomography underwent surgery using the articular detachment technique. The key point of this technique was anatomical reduction and subchondral fixation of the coronal split articular fragment to the superior main fragment after complete detachment of the coronal split fragment from the inferior pole. The remaining inferior pole was fixed using a separate construct. Postoperative articular gap, articular step-off, and complications, including resorption, reduction loss, and avascular necrosis of fixed articular fragments, were evaluated as radiological outcomes. Range of motion and the Lysholm scores were used to evaluate clinical outcomes. Among the 15 patients, the coronal split articular fragments were fixed using Kirschner wires in 13 patients and headless screws in 2 patients. The inferior poles were fixed using separate vertical wiring in 13 patients and tension-band wiring in 2 patients. A postoperative articular gap was noted in 7 patients, with an average articular gap of 1.0 mm (range, 0.7-1.6 mm). No articular step-off was observed. Bone union and normal range of motion were achieved in all patients. On the 1-year postoperative lateral radiograph, resorption of the articular fracture site was seen in 5 patients. There was no loss of reduction or avascular necrosis of the coronal split articular fragments. The average postoperative Lysholm score at 1 year was 89.3 ± 4.1 (range, 82-95). The technique would be a reliable and safe option for the surgical treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments in terms of anatomical reduction and stable fixation of articular fragments without risk of avascular necrosis.
Sections du résumé
Background
UNASSIGNED
Treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments is a challenge. To treat this difficult fracture, we perform articular fragment detachment and separate fixation for coronal split articular and inferior pole fragments. We aimed to evaluate the radiological and clinical outcomes of our technique in comminuted patellar fractures at least 1 year after surgery.
Methods
UNASSIGNED
Between January 2019 and June 2022, 15 patients diagnosed with comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments based on preoperative computed tomography underwent surgery using the articular detachment technique. The key point of this technique was anatomical reduction and subchondral fixation of the coronal split articular fragment to the superior main fragment after complete detachment of the coronal split fragment from the inferior pole. The remaining inferior pole was fixed using a separate construct. Postoperative articular gap, articular step-off, and complications, including resorption, reduction loss, and avascular necrosis of fixed articular fragments, were evaluated as radiological outcomes. Range of motion and the Lysholm scores were used to evaluate clinical outcomes.
Results
UNASSIGNED
Among the 15 patients, the coronal split articular fragments were fixed using Kirschner wires in 13 patients and headless screws in 2 patients. The inferior poles were fixed using separate vertical wiring in 13 patients and tension-band wiring in 2 patients. A postoperative articular gap was noted in 7 patients, with an average articular gap of 1.0 mm (range, 0.7-1.6 mm). No articular step-off was observed. Bone union and normal range of motion were achieved in all patients. On the 1-year postoperative lateral radiograph, resorption of the articular fracture site was seen in 5 patients. There was no loss of reduction or avascular necrosis of the coronal split articular fragments. The average postoperative Lysholm score at 1 year was 89.3 ± 4.1 (range, 82-95).
Conclusions
UNASSIGNED
The technique would be a reliable and safe option for the surgical treatment of comminuted patellar fractures accompanied by coronal split articular and inferior pole fragments in terms of anatomical reduction and stable fixation of articular fragments without risk of avascular necrosis.
Identifiants
pubmed: 38827765
doi: 10.4055/cios23302
pmc: PMC11130619
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
357-362Informations de copyright
Copyright © 2024 by The Korean Orthopaedic Association.
Déclaration de conflit d'intérêts
CONFLICT OF INTEREST: No potential conflict of interest relevant to this article was reported.