"Long-term effects of center volume on transplant outcomes in adult kidney transplant recipients".
Journal
PloS one
ISSN: 1932-6203
Titre abrégé: PLoS One
Pays: United States
ID NLM: 101285081
Informations de publication
Date de publication:
2024
2024
Historique:
received:
18
04
2023
accepted:
17
03
2024
medline:
6
6
2024
pubmed:
6
6
2024
entrez:
6
6
2024
Statut:
epublish
Résumé
The influence of center volume on kidney transplant outcomes is a topic of ongoing debate. In this study, we employed competing risk analyses to accurately estimate the marginal probability of graft failure in the presence of competing events, such as mortality from other causes with long-term outcomes. The incorporation of immunosuppression protocols and extended follow-up offers additional insights. Our emphasis on long-term follow-up aligns with biological considerations where competing risks play a significant role. We examined data from 219,878 adult kidney-only transplantations across 256 U.S. transplant centers (January 2001-December 2015) sourced from the Organ Procurement and Transplantation Network registry. Centers were classified into quartiles by annual volume: low (Q1 = 28), medium (Q2 = 75), medium-high (Q3 = 121), and high (Q4 = 195). Our study investigated the relationship between center volume and 5-year outcomes, focusing on graft failure and mortality. Sub-population analyses included deceased donors, living donors, diabetic recipients, those with kidney donor profile index >85%, and re-transplants from deceased donors. Adjusted cause-specific hazard ratios (aCHR) for Five-Year Graft Failure and Patient Death were examined by center volume, with low-volume centers as the reference standard (aCHR: 1.0). In deceased donors, medium-high and high-volume centers showed significantly lower cause-specific hazard ratios for graft failure (medium-high aCHR = 0.892, p<0.001; high aCHR = 0.953, p = 0.149) and patient death (medium-high aCHR = 0.828, p<0.001; high aCHR = 0.898, p = 0.003). Among living donors, no significant differences were found for graft failure, while a trend towards lower cause-specific hazard ratios for patient death was observed in medium-high (aCHR = 0.895, p = 0.107) and high-volume centers (aCHR = 0.88, p = 0.061). Higher center volume is associated with significantly lower cause-specific hazard ratios for graft failure and patient death in deceased donors, while a trend towards reduced cause-specific hazard ratios for patient death is observed in living donors.
Sections du résumé
BACKGROUND
BACKGROUND
The influence of center volume on kidney transplant outcomes is a topic of ongoing debate. In this study, we employed competing risk analyses to accurately estimate the marginal probability of graft failure in the presence of competing events, such as mortality from other causes with long-term outcomes. The incorporation of immunosuppression protocols and extended follow-up offers additional insights. Our emphasis on long-term follow-up aligns with biological considerations where competing risks play a significant role.
METHODS
METHODS
We examined data from 219,878 adult kidney-only transplantations across 256 U.S. transplant centers (January 2001-December 2015) sourced from the Organ Procurement and Transplantation Network registry. Centers were classified into quartiles by annual volume: low (Q1 = 28), medium (Q2 = 75), medium-high (Q3 = 121), and high (Q4 = 195). Our study investigated the relationship between center volume and 5-year outcomes, focusing on graft failure and mortality. Sub-population analyses included deceased donors, living donors, diabetic recipients, those with kidney donor profile index >85%, and re-transplants from deceased donors.
RESULTS
RESULTS
Adjusted cause-specific hazard ratios (aCHR) for Five-Year Graft Failure and Patient Death were examined by center volume, with low-volume centers as the reference standard (aCHR: 1.0). In deceased donors, medium-high and high-volume centers showed significantly lower cause-specific hazard ratios for graft failure (medium-high aCHR = 0.892, p<0.001; high aCHR = 0.953, p = 0.149) and patient death (medium-high aCHR = 0.828, p<0.001; high aCHR = 0.898, p = 0.003). Among living donors, no significant differences were found for graft failure, while a trend towards lower cause-specific hazard ratios for patient death was observed in medium-high (aCHR = 0.895, p = 0.107) and high-volume centers (aCHR = 0.88, p = 0.061).
CONCLUSION
CONCLUSIONS
Higher center volume is associated with significantly lower cause-specific hazard ratios for graft failure and patient death in deceased donors, while a trend towards reduced cause-specific hazard ratios for patient death is observed in living donors.
Identifiants
pubmed: 38843258
doi: 10.1371/journal.pone.0301425
pii: PONE-D-23-11616
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
e0301425Informations de copyright
Copyright: © 2024 Azhar et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Déclaration de conflit d'intérêts
The authors declare on conflict of interest related to this work. G Gupta has received honoraria from Alexion, CareDx, Mallinckrodt; has served on the Scientific Advisory Board for CareDx, Natera, Relypsa, Veloxis; and has received research funding from Gilead and Merck.