Comparison of aqueous and non-aqueous capillary electrophoresis for the determination of four benzalkonium chloride homologues in compound chemical disinfectants.

Benzalkonium chloride Compound chemical disinfectants Micellar electrokinetic chromatography Non-aqueous capillary electrophoresis Ultraviolet detection

Journal

Heliyon
ISSN: 2405-8440
Titre abrégé: Heliyon
Pays: England
ID NLM: 101672560

Informations de publication

Date de publication:
15 Jun 2024
Historique:
received: 21 12 2023
revised: 20 05 2024
accepted: 22 05 2024
medline: 7 6 2024
pubmed: 7 6 2024
entrez: 7 6 2024
Statut: epublish

Résumé

A new method was established for the simultaneous analysis of four homologous benzalkonium chlorides (dodecyldimethylbenzyl ammonium chloride, tetradecyldimethylbenzyl ammonium chloride, hexadecyldimethylbenzyl ammonium chloride, and octadecyldimethylbenzyl ammonium chloride) in compound chemical disinfectants using non-aqueous capillary electrophoresis (CE) based on a micellar electrokinetic chromatography mode with direct ultraviolet detection. The separation was performed on an uncoated fused quartz capillary with a total length of 60.2 cm and a diameter of 25 μm. The separation buffer consisted of a mixture of methanol/acetonitrile (60:40, v/v) containing 70 mmol/L sodium acetate, 60 mmol/L trifluoroacetic acid and 20 mmol/L sodium dodecyl sulfate. The sample buffer was a methanol solution containing only 2 mmol/L trifluoroacetic acid. The separation voltage was set at 8 kV with a working current of approximately 2.3 μA. The detection wavelength was 214 nm. Under optimal conditions, the limit of detection and limit of quantification for these four benzalkonium chlorides (BACs) were 1.0 mg/L and 5.0 mg/L, respectively. Good linearities were observed in the concentration ranges from 5.0 to 100.0 mg/L, with correlation coefficients above 0.999 for all compounds. The recoveries of these four BACs ranged from 92.5 % to 109.1 % with relative standard deviations below 4.7 %. With the new method, all four BACs could be analyzed in a single injection. In contrast, the aqueous CE method in the National Standard GB/T 26369-2020 only allowed for the simultaneous analysis of the first three homologous. The new method demonstrated the improved peak shape compared to the aqueous CE method and then was successfully applied to the analysis of 19 commercially available samples, such as object table disinfectants, hand sanitizers, and disinfectant wipes, which claimed to contain quaternary ammonium compound. The results obtained using the new method were compared with those of the aqueous CE of the National Standard Method, and no statistically significant differences were observed. The new method is simple in pre-treatment and provides accurate results, making it highly suitable for routine analysis.

Identifiants

pubmed: 38845926
doi: 10.1016/j.heliyon.2024.e31797
pii: S2405-8440(24)07828-9
pmc: PMC11154611
doi:

Types de publication

Journal Article

Langues

eng

Pagination

e31797

Informations de copyright

© 2024 Beijing Center for Disease Pvevention and Control.

Déclaration de conflit d'intérêts

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Kai Yao (K)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Ruoke Jiang (R)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Ping Wang (P)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Jing Zhang (J)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Bing Shao (B)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Xiaojing Ding (X)

Beijing Key Laboratory of Diagnostic and Traceability Technologies for Food Poisoning, Beijing Center for Disease Prevention and Control, Beijing, 100013, China.

Classifications MeSH