Salvage strategy for long-term central venous catheter-associated Staphylococcus aureus infections in children: a multicenter retrospective study in France.
Staphylococcus aureus
bacteremia
catheter-related infection/microbiology
central venous catheters
child
Journal
The Journal of hospital infection
ISSN: 1532-2939
Titre abrégé: J Hosp Infect
Pays: England
ID NLM: 8007166
Informations de publication
Date de publication:
14 Jun 2024
14 Jun 2024
Historique:
received:
26
02
2024
revised:
28
04
2024
accepted:
29
04
2024
medline:
17
6
2024
pubmed:
17
6
2024
entrez:
16
6
2024
Statut:
aheadofprint
Résumé
Catheter removal is recommended in adults with S. aureus central line-associated bloodstream infection (CLABSI) but is controversial in children with long-term central venous catheters (LTCVC). We evaluated the occurrence of catheter salvage strategy (CSS) in children with S. aureus LTCVC-associated CLABSI and assessed determinants of CSS failure. We retrospectively included children (<18 years) with an LTCVC and hospitalized with S. aureus CLABSI in 8 French tertiary care hospitals (2010-2018). CSS was defined as an LTCVC left in place ≥ 72 hours after initiating empiric antibiotic treatment for suspected bacteremia. Characteristics of patients were reviewed, and multivariable logistic regression was performed to identify factors associated with CSS failure (i.e., persistence, recurrence, or complications of bacteremia). We included 273 episodes of S. aureus LTCVC-associated CLABSI. CSS was chosen in 194 out of 273 (71%) cases and failed in 74 of them (38%). The main type of CSS failure was the persistence of bacteremia (39 out of 74 cases, 53%). Factors independently associated with CSS failure were: history of catheter infection (adjusted odds ratio [aOR] 3.18, 95% confidence interval [95%CI] 1.38-7.36), CLABSI occurring on an implantable venous access device (aOR 7.61, 95%CI 1.98-29.20) when compared with tunneled-cuffed CVC, polymicrobial CLABSI (aOR 3.45, 95%CI 1.25-9.50), and severe sepsis at the initial stage of infection (aOR 4.46, 95%CI 1.18-16.82). CSS was frequently chosen in children with S. aureus LTCVC-associated CLABSI, and failure occurred in one-third of cases. The identified risk factors may help clinicians identify children at risk for CSS failure.
Identifiants
pubmed: 38880286
pii: S0195-6701(24)00206-8
doi: 10.1016/j.jhin.2024.04.030
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of Competing Interest None.