Diagnostic Accuracy of D-Dimer for Acute Aortic Syndromes: Systematic Review and Meta-Analysis.
Journal
Annals of emergency medicine
ISSN: 1097-6760
Titre abrégé: Ann Emerg Med
Pays: United States
ID NLM: 8002646
Informations de publication
Date de publication:
18 Jun 2024
18 Jun 2024
Historique:
received:
05
01
2024
revised:
28
03
2024
accepted:
01
05
2024
medline:
18
6
2024
pubmed:
18
6
2024
entrez:
18
6
2024
Statut:
aheadofprint
Résumé
Acute aortic syndrome is a life-threatening emergency condition. Previous systematic reviews of D-dimer diagnostic accuracy for acute aortic syndrome have been contradictory and based on limited data, but recently published studies offer potential for a more definitive overview. We aimed to perform a systematic review and meta-analysis to determine the diagnostic accuracy of D-dimer for diagnosing acute aortic syndrome. We searched MEDLINE, EMBASE, and the Cochrane Library from inception to February 2024. Additionally, the reference lists of included studies and other systematic reviews were thoroughly searched. All diagnostic cohort studies (prospective or retrospective) that assessed the use of D-dimer for diagnosing acute aortic syndrome compared with a reference standard test (eg, computed tomographic angiography (CTA), ECG-gated CTA, echocardiography, magnetic resonance angiography, operation, or autopsy) were included. Two independent reviewers completed study selection, data extractions and quality assessment using the Quality Assessment of Diagnostic Accuracy Studies-2 (QUADAS-2) tool. Data were synthesized using a bivariate meta-analysis model. Of 2017 potentially relevant citations, 25 cohort studies met the inclusion criteria, and 18 reporting the 500 ng/mL threshold were included in the primary meta-analysis. Risk of bias domains were mostly unclear due to limited study reporting. The summary sensitivity was 96.5% (95% credible interval [CrI] 94.8% to 98%) and summary specificity was 56.2% (95% CrI, 48.3% to 63.9%). Study specificity varied markedly from 33% to 86%, indicating substantial heterogeneity. Sensitivity analysis including the 7 studies reporting other thresholds showed summary sensitivity of 95.7% (95% CrI, 93.2% to 97.5%) and summary specificity of 57.5% (95% CrI, 50.1% to 64.6%). D-dimer concentration has high sensitivity (96.5%) and moderate specificity (56.2%) for acute aortic syndrome, with some uncertainty around estimates due to risk of bias and heterogeneity. Previous meta-analysis reporting higher specificity may be explained by inclusion of case-control studies that may overestimate accuracy.
Identifiants
pubmed: 38888529
pii: S0196-0644(24)00260-9
doi: 10.1016/j.annemergmed.2024.05.001
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Informations de copyright
Copyright © 2024 American College of Emergency Physicians. Published by Elsevier Inc. All rights reserved.