Reducing the lateral dose penumbra in IMPT by incorporating transmission pencil beams.
Journal
Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology
ISSN: 1879-0887
Titre abrégé: Radiother Oncol
Pays: Ireland
ID NLM: 8407192
Informations de publication
Date de publication:
17 Jun 2024
17 Jun 2024
Historique:
received:
04
04
2024
revised:
30
05
2024
accepted:
13
06
2024
medline:
20
6
2024
pubmed:
20
6
2024
entrez:
19
6
2024
Statut:
aheadofprint
Résumé
In intensity-modulated proton therapy (IMPT), Bragg peaks result in steep distal dose fall-offs, while the lateral IMPT dose fall-off is often less steep than in photon therapy. High-energy pristine transmission ('shoot through') pencil beams have no Bragg peak in the patient, but show a sharp lateral penumbra at the target level. We investigated whether combining Bragg peaks with Transmission pencil beams('IMPT&TPB') could improve head-and-neck plans by exploiting the steep lateral dose fall-off of transmission pencil beams. Our system for automated multi-criteria IMPT plan optimisation was extended for combined optimisation of BPs and TPBs. The system generates for each patient a Pareto-optimal plan using a generic 'wish-list' with prioritised planning objectives and hard constraints. For eight nasopharynx cancer patients (NPC) and eight oropharynx cancer (OPC) patients, the IMPT&TPB plan was compared to the competing conventional IMPT plan with only Bragg peaks, which was generated with the same optimiser, but without transmission pencil beams. Clinical OAR and target constraints were met in all plans. By allowing transmission pencil beams in the optimisation, on average 14 of the 25 investigated OAR plan parameters significantly improved for NPC, and 9 of the 17 for OPC, while only one OPC parameter showed small but significant deterioration. Non-significant differences were found in the remaining parameters. In NPC, cochlea Dmean reduced by up to 17.5 Gy and optic nerve D Compared to IMPT, IMPT&TPB resulted in comparable target coverage with overall superior OAR sparing, the latter originating from steeper dose fall-offs close to OARs.
Identifiants
pubmed: 38897315
pii: S0167-8140(24)00658-3
doi: 10.1016/j.radonc.2024.110388
pii:
doi:
Types de publication
Journal Article
Langues
eng
Sous-ensembles de citation
IM
Pagination
110388Informations de copyright
Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.
Déclaration de conflit d'intérêts
Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.