Deep Learning for hand tracking in Parkinson's Disease video-based assessment: Current and future perspectives.

Bradykinesia Computer vision Deep learning Hand tracking MDS-UPDRS Parkinson’s disease Tremor

Journal

Artificial intelligence in medicine
ISSN: 1873-2860
Titre abrégé: Artif Intell Med
Pays: Netherlands
ID NLM: 8915031

Informations de publication

Date de publication:
17 Jun 2024
Historique:
received: 31 10 2023
revised: 19 05 2024
accepted: 21 05 2024
medline: 24 6 2024
pubmed: 24 6 2024
entrez: 23 6 2024
Statut: aheadofprint

Résumé

Parkinson's Disease (PD) demands early diagnosis and frequent assessment of symptoms. In particular, analysing hand movements is pivotal to understand disease progression. Advancements in hand tracking using Deep Learning (DL) allow for the automatic and objective disease evaluation from video recordings of standardised motor tasks, which are the foundation of neurological examinations. In view of this scenario, this narrative review aims to describe the state of the art and the future perspective of DL frameworks for hand tracking in video-based PD assessment. A rigorous search of PubMed, Web of Science, IEEE Explorer, and Scopus until October 2023 using primary keywords such as parkinson, hand tracking, and deep learning was performed to select eligible by focusing on video-based PD assessment through DL-driven hand tracking frameworks RESULTS:: After accurate screening, 23 publications met the selection criteria. These studies used various solutions, from well-established pose estimation frameworks, like OpenPose and MediaPipe, to custom deep architectures designed to accurately track hand and finger movements and extract relevant disease features. Estimated hand tracking data were then used to differentiate PD patients from healthy individuals, characterise symptoms such as tremors and bradykinesia, or regress the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) by automatically assessing clinical tasks such as finger tapping, hand movements, and pronation-supination. DL-driven hand tracking holds promise for PD assessment, offering precise, objective measurements for early diagnosis and monitoring, especially in a telemedicine scenario. However, to ensure clinical acceptance, standardisation and validation are crucial. Future research should prioritise large open datasets, rigorous validation on patients, and the investigation of new frontiers such as tracking hand-hand and hand-object interactions for daily-life tasks assessment.

Sections du résumé

BACKGROUND BACKGROUND
Parkinson's Disease (PD) demands early diagnosis and frequent assessment of symptoms. In particular, analysing hand movements is pivotal to understand disease progression. Advancements in hand tracking using Deep Learning (DL) allow for the automatic and objective disease evaluation from video recordings of standardised motor tasks, which are the foundation of neurological examinations. In view of this scenario, this narrative review aims to describe the state of the art and the future perspective of DL frameworks for hand tracking in video-based PD assessment.
METHODS METHODS
A rigorous search of PubMed, Web of Science, IEEE Explorer, and Scopus until October 2023 using primary keywords such as parkinson, hand tracking, and deep learning was performed to select eligible by focusing on video-based PD assessment through DL-driven hand tracking frameworks RESULTS:: After accurate screening, 23 publications met the selection criteria. These studies used various solutions, from well-established pose estimation frameworks, like OpenPose and MediaPipe, to custom deep architectures designed to accurately track hand and finger movements and extract relevant disease features. Estimated hand tracking data were then used to differentiate PD patients from healthy individuals, characterise symptoms such as tremors and bradykinesia, or regress the Movement Disorder Society-Unified Parkinson's Disease Rating Scale (MDS-UPDRS) by automatically assessing clinical tasks such as finger tapping, hand movements, and pronation-supination.
CONCLUSIONS CONCLUSIONS
DL-driven hand tracking holds promise for PD assessment, offering precise, objective measurements for early diagnosis and monitoring, especially in a telemedicine scenario. However, to ensure clinical acceptance, standardisation and validation are crucial. Future research should prioritise large open datasets, rigorous validation on patients, and the investigation of new frontiers such as tracking hand-hand and hand-object interactions for daily-life tasks assessment.

Identifiants

pubmed: 38909431
pii: S0933-3657(24)00156-8
doi: 10.1016/j.artmed.2024.102914
pii:
doi:

Types de publication

Journal Article Review

Langues

eng

Sous-ensembles de citation

IM

Pagination

102914

Informations de copyright

Copyright © 2024 The Author(s). Published by Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Gianluca Amprimo (G)

Politecnico di Torino - Control and Computer Engineering Department, Corso Duca degli Abruzzi, 24, Turin, 10129, Italy; National Research Council - Institute of Electronics, Information Engineering and Telecommunications, Corso Duca degli Abruzzi, 24, Turin, 10029, Italy. Electronic address: gianluca.amprimo@polito.it.

Giulia Masi (G)

Politecnico di Torino - Control and Computer Engineering Department, Corso Duca degli Abruzzi, 24, Turin, 10129, Italy. Electronic address: https://www.researchgate.net/profile/Giulia-Masi-2.

Gabriella Olmo (G)

Politecnico di Torino - Control and Computer Engineering Department, Corso Duca degli Abruzzi, 24, Turin, 10129, Italy. Electronic address: https://www.sysbio.polito.it/analytics-technologies-health/.

Claudia Ferraris (C)

National Research Council - Institute of Electronics, Information Engineering and Telecommunications, Corso Duca degli Abruzzi, 24, Turin, 10029, Italy. Electronic address: https://www.ieiit.cnr.it/people/Ferraris-Claudia.

Classifications MeSH