Automatic quantification of scapular and glenoid morphology from CT scans using deep learning.

Computed tomography Deep learning Morphometry Osteoarthritis Shoulder

Journal

European journal of radiology
ISSN: 1872-7727
Titre abrégé: Eur J Radiol
Pays: Ireland
ID NLM: 8106411

Informations de publication

Date de publication:
25 Jun 2024
Historique:
received: 19 01 2024
revised: 28 05 2024
accepted: 24 06 2024
medline: 1 7 2024
pubmed: 1 7 2024
entrez: 30 6 2024
Statut: aheadofprint

Résumé

To develop and validate an open-source deep learning model for automatically quantifying scapular and glenoid morphology using CT images of normal subjects and patients with glenohumeral osteoarthritis. First, we used deep learning to segment the scapula from CT images and then to identify the location of 13 landmarks on the scapula, 9 of them to establish a coordinate system unaffected by osteoarthritis-related changes, and the remaining 4 landmarks on the glenoid cavity to determine the glenoid size and orientation in this scapular coordinate system. The glenoid version, glenoid inclination, critical shoulder angle, glenopolar angle, glenoid height, and glenoid width were subsequently measured in this coordinate system. A 5-fold cross-validation was performed to evaluate the performance of this approach on 60 normal/non-osteoarthritic and 56 pathological/osteoarthritic scapulae. The Dice similarity coefficient between manual and automatic scapular segmentations exceeded 0.97 in both normal and pathological cases. The average error in automatic scapular and glenoid landmark positioning ranged between 1 and 2.5 mm and was comparable between the automatic method and human raters. The automatic method provided acceptable estimates of glenoid version (R This open-source deep learning model enables the automatic quantification of scapular and glenoid morphology from CT scans of patients with glenohumeral osteoarthritis, with sufficient accuracy for clinical use.

Identifiants

pubmed: 38944907
pii: S0720-048X(24)00304-8
doi: 10.1016/j.ejrad.2024.111588
pii:
doi:

Types de publication

Journal Article

Langues

eng

Sous-ensembles de citation

IM

Pagination

111588

Informations de copyright

Copyright © 2024 The Authors. Published by Elsevier B.V. All rights reserved.

Déclaration de conflit d'intérêts

Declaration of competing interest The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Auteurs

Osman Berk Satir (OB)

ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland.

Pezhman Eghbali (P)

Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland.

Fabio Becce (F)

Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Patrick Goetti (P)

Department of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Arnaud Meylan (A)

Department of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Kilian Rothenbühler (K)

Department of Diagnostic and Interventional Radiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Robin Diot (R)

Department of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Alexandre Terrier (A)

Laboratory of Biomechanical Orthopedics, Ecole Polytechnique Fédérale de Lausanne, Lausanne, Switzerland; Department of Orthopedics and Traumatology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland.

Philippe Büchler (P)

ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland. Electronic address: philippe.buechler@unibe.ch.

Classifications MeSH